Magneto meter, resistively meter, seismograph, gravimeter, borehole logging system, ground penetrating radar, x-ray fluorescence analyzer, sonic instrument, total station.
Level gauge, level indicator, level transmitter.
Name Moving Iron Ammeter-Voltmeter Model Analog meter Type LY-100Y Accuracy: class 2.5/1.5 Specification: 30V 50V 75V 100V 120V 150V 200V 250V 450V 500V 600V, if over 600V, meters can be connected potential transformer with secondary voltage 100V
Power line carrier communication unit The design and production of power line carrier communication unit conform to relative technical standards and specification (2013 version) of the power user electric energy data acquisition system of state grid corporation of china
Single-phase carrier module Adopting the bpsk modulation and demodulation system, the three-phase carrier module has a disturbance-resisting capacity apparently better than fsk. The chip employing the 1/2 and 3/4 code rate convolutional encoding and cyclic interleaving technology can still correctly decode under the high volume of background noise of electric power line
Zhw5-126(l)/t3150-40 electrical composite apparatus The product has advantages such as reliable performance, advanced technology, compact structure, less operating power, long service life, easy maintenance and excellent anti-seismic property
Single-phase smart watt-hour meter adopts large-scale integrated circuit and dedicated ultra-high precision energy measurement soc chip. The communications capability and reliability of its communication module has reached the level of widespread practical application. It is a modern advanced meter designed and manufactured according to the actual energy consumption conditions with the application of digital sampling technology and smt technology. Its performance indicators are in line with iec 62053-21: 2003 electricity metering equipment (a.C.) - particular requirements - part 21: static meters for active energy (classes 1 and 2), iec 62053-23: 2003 electricity metering equipment (a.C.) - particular requirements - part 23: static meters for reactive energy (classes 2 and 3) and iec 62052-11: 2003 electricity metering equipment (a.C.)general requires, tests and test conditions - part 11: metering equipment and other standards. The technical requirements of the smart meter can be made to measure the functional requirements; meanwhile, its telecommunication adopts a dedicated data encryption chip to ensure the security of quantity of electricity, tariff and other information
GF313V2 onsite portable three phase electronic meter test set is the newest product produced by our company by widely visiting users and referring to the advantages of the same kind of products home and abroad. The measured part of the product adopts high speed A D transmission to send DSP to conduct digital processing, which largely improves measured degree of accuracy and stability. Central processing part adopts 32-bit ARM embedded technology to make instrument interface novel, function abundant, operation distinct and easy, and performance steady. Class of accuracy: Class 0.1, 0.2 or 0.5, range from 3 120A 3 600V200awith comfort design, small size and light weight. The model GF313V2 three phase meter meter test set is suit for metrological service of electricity power utilities, industrial and mining enterprises and electric lab to field use.
GF112V2 made in GFUVE GROUP, is a high precision single phase handheld energy meter accuracy tester in class 0.1, used for testing all kinds of single phase electronic meters error on site. Wide measurement range from 1mA to 200A and 0 to 600V, frequency range 40.000Hz to 70.000Hz, and also can be used to test alternating current electrical parameters - voltage, current, active power, reactive power, apparent power, harmonics, phase angle, power factor, frequency, energy etc. It can display U & I wave form and vector diagram. Small size, light weight, simple and convenient operation. It is an ideal testing equipment for the metrology departments of electricity power companies and electrical service engineers.
The model GF313 handheld three phase electricity meter field tester is a economical 0.2% AC energy meter accuracy testing device, mainly used to test three phase and single phase electricity energy meter error on site, measure all various of AC electrical parameters - U, I, P, Q, S, PF, F and CT ratio & phase error etc. And then it can check whether the wiring of the electricity meter is correct. GF313 electronic meter tester is an ideal electrical test tool for the metrological service of electricity power utilities.
The GF302D1S portable three phase energy meter test system consists of an integrated 0.05% three-phase current and voltage source and a three-phase electronic reference standard meter of accuracy class 0.02. Characteristic features of the GF302D1S are its wide measuring range from 0 to 120A and 0 to 600V, high accuracy and high tolerance to unwanted external influences. The GF302D1S allows the monitoring of meter installations as well as analysis of the local mains conditions when it is as portable reference working standard. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7' touch LCD-display. Voltage & current harmonics output from 2 to 63 times. This model portable meter test system can be programmable by PC, automatic generation of energy meter error test report.
GF312V2S portable three phase reference meter on-site is the newest product produced by our company by widely visiting users and referring to the advantages of the same kind of products home and abroad. The measured part of the product adopts high speed 24bit A D transmission to send DSP to conduct digital processing, unique power compensation algorithm with patented technology, which largely improves measured degree of accuracy and stability. Central processing part adopts 32-bit ARM embedded technology to make instrument interface novel, function abundant, operation distinct and easy, and performance steady. with comfort portable design and light weight. The model GF312V2S portable reference meter is suit for electricity power utilities metrogical departments, Industrial and mining enterprises departments and electric lab to field use.
GF111B single phase reference energy meter with 100a clamp on ct is the latest product launched by our company after extensive visits to users and drawing on the advantages of similar products at domestic and abroad. The measurement part of the product adopts high-speed A D converter and DSP for digital processing technology, which greatly improves the accuracy and stability of measurement. The central processing part adopts 32-bit ARM embedded technology, which makes the instrument have novel interface, rich functions, clear and simple operation and stable performance. it has not only advantages of light weight, portable structure, high precision, high performance, powerful function, original interface, ease-to-use, but also work stability. It can measure U, I, P, Q, S, E, frequency, power factor, phase angle, harmonics etc. Accuracy class: 0.04.
The GF3000 series stationary three phase energy meter test bench is a fully automatic system that enables simultaneous, multi-position calibration and verification of three-phase electric energy meters error. Full compatibility with IEC 60736, excellent parameters, superior functionality and outstanding flexibility, It adopt the most advanced electronic measurement technique and modular concept combine the difference three phase reference standards and power amplifier. GF3000 three phase meter test equipment is applied in the measurement centre of grid company energy measurement department of power supply company and energy management utility, industrial enterprise and meter manufacturers.
The GF1000 series multi-positions single phase kWh meter test bench can measure mechanical meters, electronic mechanical meters and electricity meter error by the way of automatic, semi-automatic or manual operation. It composes of single phase programmable power source, high precision single phase reference energy meter, meter suspension test rack, Multi-channel server and precision clock source etc. GF1000 meter test bench is applied in the measurement centre of grid company energy measurement department of power supply company and energy management utility, industrial enterprise and meter manufacturers.
GF112B Single Phase kWh Meter Calibrator is suitable to test various types single phase kWh meters error on site and also can be used to test alternating current parameters - U, I, P, Q, S ,F, E etc.
GF112 handheld single phase watt-hour meter tester is with human oriented design, hand-held and lightweight. It is suit for electric power departments, measuring and quality examining departments and electric lab to field use. It is capable of testing various types single phase watt-hour meters on site and can also be used for testing alternating current parameters , for example U, I, P, Q, S, F, E etc.
GF312B2 portable three phase reference meter high accuracy 0.02%, with all kinds of optional clamp on ct and smart optical sampler. It can be applied in electrical laboratory or on site. it will be ensured by a combination of measures such as the use of 24bit A/D converter, DSP 32 bit ARM technology, a widely measuring range 600V/120A, adapted to typical test points of most recognized national metrological institutes. It can be as high precision three phase reference energy meter, also three phase portable meter calibrator, test ct pt ratio, burden etc.
GF312B portable three phase energy meter calibrator with printer is used to calibrate three phase, single phase, active and reactive energy meters error. And it also can be used as voltage, current and power meter to measure AC parameters of three phase power line. It can measure wave distortion factor and 2nd to 64nd harmonic wave. GF312B calibrator is used for grid corporation of measurement and energy test center, metrological service of power supply bureau, national energy measurement of testing authorities.
The instrument GF312D1 is a precision 0.05% AC energy meter testing instrument, mainly used to test three phase energy meter error on site, measure all various of AC parameters and CT ratio & phase error, it is also as three phase reference energy meter in the laboratory. Mainly using test single phase or three phase meter error on site. GF312D1 energy meter calibrator is an ideal test tool for the metrological service of electricity power company.