Three-phase transformers are used to convert the available 3-phase mains voltage into any load voltage.
To cater for the wide range of application areas involved,these transformers are essentially available in
the same kinds of designs as the single-phase transformers, e.g.
Three-phase dry-type transformer:
separate winding version
Three-phase series transformer:
autotransformer winding version
Three-phase safety, isolating, mains or
insulating transformer: separate winding version
In terms of how the 3 coils are connected, there are various options available and each of these provides
the transformers with specific properties. The vector group code is composed of the following elements:
The upper-case letter indicates the higher-voltage winding
(the highest voltage in terms of operation).
The lower-case letter indicates the lower-voltage winding.
The brought-out neutral is indicated by means of N or n
(depending on voltage level).
â?¢ The distinctive number indicates the phase angle of the lower voltage
in relation to the higher voltage (distinctive number multiplied by 30).
The following winding connection options are available
Delta: D, d
Wye (or star): Y, y
Zigzag: Z, z
Example: Dyn5
Higher-voltage winding is delta-connected.
Lower-voltage winding is star-connected with a brought-out neutral.
The lower voltage lags behind the higher voltage by 150�° (5 x 30�°).
Unless specifically requested otherwise, the transformers are configured with a double-star connection
and a brought-out neutral (vector group Yyn0); for autotransformers the vector group is YNa0.
Our three-phase transformer range includes all our standardised types for the 25 30.0 kVA performance range and a frequency of 50/60 Hz
Oct-26-23
Jiangyin Spark XH-SCT-T24 Series split-core current transformer , Diameter 24mm , Max rated current 300A ,output 0.333V ,1.0% class ,UL list


Features:
Small size, low cost
High secondary turns
Secure locking hinge
Features:
Maximum continuous primary current 5A to 300AAC
Current Ratio: 3000: 1
Output: 0.333 Volt or mA at rated current
Accuracy: �± 1% from 5% to 120% of rated current
Insulation Voltage: 600VAC
Maximum Primary Voltage: 5000VAC(Insulated Conductor)
Phase angle: Less than 2 degrees at 50% of rated current
Frequency Range: 50 Hz to 400 Hz
Operating Temperature: -15C to 60C.
Leads: 4Foot(105cm), UL 1015, Twisted Pair, 0.34 mm2(22AWG)
CE recognized, and RoHS compliant
Output and leads can be customized
Aug-13-21
EE30 horizontal 6+6pin customer transformers.
Aug-13-21
EE30 horizontal 6+6pin customer transformers.
Mar-15-24
Metal chip press machine introduction:
The scrap metal briquetting machine uses hydraulic system to drive the hydraulic cylinder, the output of high pressure will be metal chips, powder and other metal raw materials cold pressed into cylindrical cake, molding at the same time to ensure that the original material remains unchanged. Convenient for storage and transportation, reduce the loss in the recycling process.
267 Transformer Scrap Suppliers
Short on time? Let Transformer Scrap sellers contact you.
Jul-22-20
Nov-12-21
Apr-01-21
Supplier From China
Apr-01-21
Aug-13-22
Pure copper scrap 99.99%
High-quality cable scrap with almost no impurities
Good fatigue/abrasion/corrosion resistance
Be the bearing,switch,frame
Mar-15-21
Supplier From China
Nov-20-23
Oct-27-23
Supplier From China
Mar-28-23
Supplier From China
Nov-08-22
Supplier From China
Aug-27-21
Supplier From China
Dec-26-24
Supplier From China
Jun-10-24
Supplier From China
Dec-28-20
Supplier From China
267 Transformer Scrap Suppliers
Short on time? Let Transformer Scrap sellers contact you.