Tris(2-hydroxyethyl) isocyanurate also known as THEIC is mainly used in the preparation of polyester heat-resistant insulating paint, can also be used in coatings, pharmaceuticals, agrochemicals , plasticizers and organic synthesis intermediates. It is used in the coating industry for heat resistant wire enamels, electrical insulating, alkyd resins, urethanes, water-soluble enamels and polyesters. Specifications Apppearance: White crystalline powder Melting Range:133.50-137.00C Hydroxy Value (mgKOH/g): 640.00 ± 10.00 mgKOH/g Acidity (mgKOH/g): 1.1 mgKOH/g pH Value: 6.5-7.5 Packing 25 kg bag; 30 bags per pallet
- PERFECT PROTECTION: The 9500-N95 NIOSH approved N95 disposable respirator mask from Makrite Industries Inc. is a testament to the quality and reliability of personal protective equipment (NIOSH Approval Number: TC-84A-5411). It provides at least 95% filtration efficiency and reliable breathing protection against aerosols free of oil and/or non-volatile liquid particles. - EASY TO BREATH: Our premium filter material provides extremely low breathing resistance and full protection to the wearer for at least 8 hours. - EXCELLENT FIT: The adjustable nosepiece is made of durable aluminum and can be shaped easily along your nose bridge to prevent leakage and eyewear fogging. The high elasticity head-straps ensure a tight and secure seal. - SOFT & COMFORTABLE: The softness of the surface material gives you a first class experience, and the inner urethane foam gives greater comfort to those who wear it throughout the day. - USE FOR: Medical Setting Personal Protection with FDA 510(k) K02047, Industrial Use, Laboratory Use, etc. - DECONTAMINATION COMPATIBLE: Battelle CCDS Critical Care Decontamination System tested for decontaminating and reuse
2001J Mainline Packers meet the highest standards for testing and sealing joints of mainline sewer pipes with acrylamide, acrylate or urethane gels. Logiball 2001J Mainline Packers meet the highest standards for testing and sealing joints of mainline sewer pipes with acrylamide, acrylate or urethane gels. A thick, reinforced SBR rubber sleeve is bonded to the stainless-steel core and a layer of softer rubber is applied over the seating portion to provide superior seating against rough surfaces. The smooth outer finish reduces the adherence of the grout on the packer. Logiball 2001J Mainline Packers come with two grout ports and a third port dedicated for the test medium (air or water). MAIN FEATURES: Void Pressure Monitoring Systems: Two different void pressure monitoring systems are available to accurately transmit the void test and grouting pressures to a gauge read by the camera or through a pressure transducer. The conventional localized sensor is recommended for acrylamide and acrylate grouts. The in-wall water chamber sensor is recommended for stickier grouts such as urethane gels and polyurethanes. The 2001J Packer can be ordered with both systems or one of the two as needed by customer. Dedicated Test Port: By using a dedicated hose from the truck to the packer for the test medium (air/water), â??Hâ?? blocks are eliminated and the mixing ratio of the two-part grout is kept constant (no flushing of the catalyst when testing). Features Three-Function Adjustable Rubber Check-Valve: They provide added safety against syphoning the tanks and unwanted backflow contamination into the hoses, and provide a good mixing of the two-part chemicals through the fan like stream of the opposed and adjacent ports. The Autotesting Concept: When inflating the 2001J packers, the ends first seal against the pipe wall, while its central portion progressively expands, trapping air and water, and compressing it into the mixing chamber. The pressure in the chamber is transmitted through the improved liquid filled sensor and/or the in-wall water chamber sensor to a gauge or transducer installed on the packer. The operator can tell if a joint is obviously good or not by simply inflating the packer over it. By avoiding time consuming conventional tests, productivity could be increased by as much as 30%. Logiball 2001J Packers approximate void volumes. ICGA promotes the proper use of chemical grouting as a safe, economical and effective mean to reduce ground water.
Lateral Test and Seal Packers Logiball 2001L packers are used to test and seal off infiltration in sewer laterals, from the mainline, without any access to cleanouts. The lateral grouting plug is inverted and deployed into the lateral from the mainline packer assembly. The mainline sleeve then expands to create a minimal grout mixing chamber. The grout is pumped and migrates freely along the restricted expansion of the lateral plug and out through existing pipe defects into the surrounding bedding to seals defects, leaving only a thin layer of grout in the lateral. The packers are available with different void pressure monitoring systems; a conventional localized liquid filled sensor (S), recommended for acrylamide and acrylate grouts, an in-wall water chamber sensor (W), recommended for stickier grouts such as urethanes and polyurethanes, or both systems (S+W) for a more versatile use. The 2001L Lateral Packer comes standard with two grout ports and a third port dedicated for the test medium (air or water). 2001L Lateral packers work best with a five-hose system. Lateral Grouting Plugs can be interchanged in a matter of minutes to grout distances up to 30 feet if necessary. Lateral Grouting Plugs are available for 4, 5 or 6 diameter laterals. Flexible housing extensions are needed for lateral grouting plugs 24 or longer. ICGA promotes the proper use of chemical grouting as a safe, economical and effective means to reduce ground water infiltration into sewer collection systems. The 2001L model is available for 6â?³, 8â?³, 9â?³, 10â?³, 12â?³, 15â?³, 18â?³, 21â?³, 24â?³ and 30â?³ mainlines. For larger diameter contact our sales department. For larger diameters, see our Man Entry Lateral Packers for 36â??â?? & up or contact our sales department. Features * As measured on the rubber. Specifications subject to change without notice. Logiball Lateral Packer Approximate Void Volumes. View list of parts for the lateral packers 2001L. (pdf file) A Control Panel is available to operate the lateral packer from the truck.