Used for low pressure line acceptance testing, sewer pipe plugging and flow control. Our pneumatic plugs can be used for pipe sizes ranging from 4â?? to 36â??. Three different models are available: Type A: No flow-thru Type B: Flow-thru by-pass plug with a 2â?? hose (�½â?? hose for the 4-8 model) Type C: Flow-thru by-pass plug with two �½â?? hoses Our sewer plugs are designed to comply with the highest safety standards and include the following features: a two-ply cross-biased reinforced SBR rubber sleeve, anchoring device and end-plate retaining device for maximum strength. To ensure the quality of our products, every inflatable plug is individually tested under severe pressure. Each Logiball Securimax pipe plug is identified by a unique serial number and comes with a test certificate, a leaflet describing the features of the sewer plug and the information on its safe use.
Safety Inflation Hose Systems Color-coded Safety Inflation Hose Systems, composed of 15 feet of 1/4 or 3/8 air line, pressure regulator, liquid filled pressure gauge, ball valve and appropriate safety valve (25 or 45 P.S.I.). Length of hoses may vary upon customer request.
Reprocessing Plugs Logiball Reprocessing Plugs are field-tested and approved by relining contractors around the world. Ideal for reprocessing the CIPP liners or installing FF liners in pipe sizes ranging from 6â?? to 21â??. These plugs come with a 1/2â?? thick rubber sleeve, reinforced with multiple layers of fabric, and molded on an aluminum core. Steel or stainless-steel construction are also available upon request. FEATURES Rubber sleeves can be factory-replaced. Larger and custom-made configurations are possible. Contact us with your requirements to request a quote.
Controlling the live flows from the surface Logiball multisize high/low flow inflatable sewer plugs allow for optimal flow control during CCTV inspection, pipe reinstatement or sectional lining. By maintaining the sewer flow active, under control and at a reasonable level, work can be performed downstream without completely blocking the flow or requiring bypass pumping. The active flow is controlled from above ground, with the Logiball High Flow/Low Flow Plug. When inflating the plug, the outer bladder expands and seals the host pipe. A separate controlled air line is used to expand the internal sleeve, similar to a pneumatic pinch valve, which reduces the amount of flow going through the center of the plug. The operator can decide how much water flow is allowed to go through the plug by pressurizing or depressurizing the internal seal from the surface, never having to enter the manhole. By releasing the pressure in the internal sleeve, flow is allowed to go through the plug, reducing the back pressure applied on the plug and allowing for a safe plug removal. Features Logiball High Flow/Low Flow Plugs cannot be used for air testing. Air hoses sold separately.
Lightweight inflatable type E plugs Logiball lightweight inflatable type E plugs are your best option for submerged pipes and short sections of pipes. Each plug is factory-tested at the factory at twice the recommended inflation pressure. The light and compact structure of these multisize plugs makes it possible to safely plug small pipes from the surface, using a pipe handle. Perfect for tight, hard-to-reach places, these rubber plugs come with a strong anchoring chain and are made to be used with a standard pipe handle.
Logiball Type D inflatable sewer plug Logiball Type D inflatable sewer plugs are a great tool for by-pass pumping and/or flow diversion when performing manhole and invert rehabilitation. Our Type D pipe plugs feature a double-action bladder: When inflating the plug, the inner bladder forms a tight seal around the by-pass pipe or the pump suction hose, while the outer bladder completely seals against the pipe wall. This â??slip it in and inflate unique feature will save you both time and effort. Logiball Type D plugs are available for pipe sizes ranging from 3â up to 16 in diameter.
Logiball push-type cleanout plugs (type a & b) Logiball push-type inflatable rubber plugs are offered with or without flow-thru for pipe diameters ranging from 3â?³ to 6â?³. These flexible plugs can be inflated and pushed from the cleanout with the optional semi-rigid hose assembly.
Lateral Test and Seal Packers Logiball 2001L packers are used to test and seal off infiltration in sewer laterals, from the mainline, without any access to cleanouts. The lateral grouting plug is inverted and deployed into the lateral from the mainline packer assembly. The mainline sleeve then expands to create a minimal grout mixing chamber. The grout is pumped and migrates freely along the restricted expansion of the lateral plug and out through existing pipe defects into the surrounding bedding to seals defects, leaving only a thin layer of grout in the lateral. The packers are available with different void pressure monitoring systems; a conventional localized liquid filled sensor (S), recommended for acrylamide and acrylate grouts, an in-wall water chamber sensor (W), recommended for stickier grouts such as urethanes and polyurethanes, or both systems (S+W) for a more versatile use. The 2001L Lateral Packer comes standard with two grout ports and a third port dedicated for the test medium (air or water). 2001L Lateral packers work best with a five-hose system. Lateral Grouting Plugs can be interchanged in a matter of minutes to grout distances up to 30 feet if necessary. Lateral Grouting Plugs are available for 4, 5 or 6 diameter laterals. Flexible housing extensions are needed for lateral grouting plugs 24 or longer. ICGA promotes the proper use of chemical grouting as a safe, economical and effective means to reduce ground water infiltration into sewer collection systems. The 2001L model is available for 6â?³, 8â?³, 9â?³, 10â?³, 12â?³, 15â?³, 18â?³, 21â?³, 24â?³ and 30â?³ mainlines. For larger diameter contact our sales department. For larger diameters, see our Man Entry Lateral Packers for 36â??â?? & up or contact our sales department. Features * As measured on the rubber. Specifications subject to change without notice. Logiball Lateral Packer Approximate Void Volumes. View list of parts for the lateral packers 2001L. (pdf file) A Control Panel is available to operate the lateral packer from the truck.
Logiscell+ activated oakum kit is composed of dry oakum soaked into a hydrophilic polymer solution to seal manholes and sewer lines. When wet and caulked in a joint or crack, the resin will foam to form a flexible and tight joint to stop groundwater infiltration. It reacts with water and becomes a watertight rubberlike non-toxic composite. The oakum cord gives strength and density to the composite and makes the application of the resin easier, especially when gushers are present. The kit includes a 1.7-liter bottle of Logiscell+ (hydrophilic resin) and one bag containing a �± 0.6 lbs of dry oakum. 18 liter pails also available. ACTIVATED OAKUM TECHNIQUE: 1) When mixed with water the resin forms a spongy foam which could absorb up to 12 times its volume of water. A non-controlled expansion could create a low-density foam, which is less watertight and resistant. If the oakum is well-inserted and uniform within the area, a good density and expansion is obtained to fill the void and stop leaks. 2) After approximately 40 seconds, the reinforced foam resin starts to react to form a rubbery gasket which becomes hard, watertight and adheres to the surface. Note: If there is a significant flow within the joint or crack, it is preferable to soak the oakum and let it partially react before the insertion in the crack or joint. By holding it tightly within the crack or joint, the resin will not be washed away by the gushing water. This technique can also be used for underwater applications. CAUTION: Prevent any contact with eyes and skin. Always wear PPE (gloves, goggles, disposable suit and mask or respirator depending on the environment). Certain people may be affected by the vapours during the reaction of the resin. To prevent irritation of throat or eyes always ventilate the working area. If it is impossible to ventilate use a mask with appropriate cartridge. Wash hands and face thoroughly after installation.