Three Phase Double Tariff Meter (DTS353) Executive Standard: IEC62052-11 2003; IEC62053-21 2003 DIN-rail standard: "SO"43864. Function and characteristic: Two tariffs; Double LCD; Control tariff by exterior controller; Two display window for two different tariffs T1, T2. Technical data: Rated Voltage: 3*220V/380V; 3*230V/400V Rated Current: 3*5(30)A; 3*10(60)A; 3*10(100)A Frequency: 50-60Hz Connection Mode: Direct type Display: LCD 5+1=99999.9kWh Accuracy Class: 1.0; Power Consumption: Less than 0.6W; Less than 0.3VA Start current: 0.004Ib Constant: 800/1600/3200/6400imp/kWh. Size: 122*100*65mm.
Single Phase kWh Meter Executive Standard: IEC62052-11 2003; IEC62053-21 2003 Function and characteristic: Infrared function; Measurement accurately. Technical data: Rated current: 1.5(6)A 5(30)A 10(40)A 5(60)A 20(80)A Rated voltage: 110V 220V 230V 240V Display mode: LCD 6+1=999999.9kWh Accuracy class: 1.0 Frequency: 50Hz (60Hz) Impulse constant: 800/1600imp/kWh Connetion mode: CT type; Direct type. Size: 153*118*50mm.
Function random phase measurement, AC current and leak current measurement, AC Voltage detection, distinguish the inductive circuit and capacitive circuit, sequence of three-phase voltage detection and connection group of transformer detection, etc. Power supply DC9V alkaline dry battery LR6f-6 continuous duty :300h LCD 3-1/2 LCD display Dimension Width *length* thick·ª92mmf-192mmf-50mm LCD dimension Display domain·ª64mmf-54mm ·+font high·ª40mm Clamp mouth ¬+7.5mm ·+¬+40mm lectotype·¼ Measuring range phase·ª0~360fp·+current·ª0~200mA/2A/10A·+voltage·ª0~20V/200V/500V resolution phase·ª1fp·+current·ª0.1mA·+voltage·ª0.01V Measurement accuracy ·+50Hz,23f¦f+1f¦·+40-60%RH·¼ phase·ªf+3fp current·ªf+1%f+2dgt Voltage·ªf+1.2%f+2dgt line voltage Line test under AC500V Sampling speed About 3 times /s Signal frequency sine wave 45Hz~55Hz ¬-=0.05 Data hold Data holding function·ªdisplayed by fªDHfª symbol Back light function Blue back light ,suit for dark occasion Automatic shutdown After starting up 15min·+it shutdown automatically to reduce battery consumption Battery voltage When battery voltage is low ,battery low voltage symbol will filker to remind replacing battery; Quality Core about590g·+with battery·¼·+long flat nose current pliers about ·ª175gf-2·+big round tongs clamp·ª120g Work temperature and moisture -10f¦~40f¦·+85%rh below Storage temperature and moisture -20f¦~60f¦·+70%rh below Driving point impedance AC voltage driving point impedance·ª2M¬+·+when test phase U1-U2·ª40K¬+ Insulation intension fª10M¬+9·+Between wire of meter and crust·+two voltage input port·¼ Voltage bear Between port of voltage input and box, split core type currenttransformator and clamp handle& winding coil: 1000V/50Hz, 1min experiment can be reach when sine wave AC voltage 500V/50Hz between port of voltage input. 92*192*50(mm)
Aliava avf250 series is a common used various flow meter in auto-industry process control. It's with small volume, wide range and easily operation. It could also measure liquid, gas and steam flow rate, especially fit for small flow rate application. Features 4 digit flow rate & 8 digit totalizer Local indication without auxiliary power 4-20 ma & scale pulse output Low pressure lost on gas and steam application Damper for gas/steam application Consistent overall length Heating jacket design Intrinsically safe & explosion proof for hazardous area Specification Size: 15, 20, 25, 40, 50, 65, 80, 100, 125, 150, 200 mm Measuring range: Liquid - 1 ~ 200000 liter/hr Gas - 0.03 ~ 4000 m3/hr Turndown ratio: 10:1 (20:1 optional) Accuracy: +/-1.6%(standard) +/-1.0%(optional) Material: Tube & float: Stainless steel 304 Stainless steel 316 Stainless steel 316l Stainless steel + ptfe liner Standard pressure: 40 kg/cm2 (15mm ~ 50mm) 16 kg/cm2 (65mm ~ 200mm) Flange type: Jis 10k / jis 20k / jis 40k / ansi 150# / ]ansi 300# / ansi 600# / din pn 10 / Pn 16 / pn25 / pn 40 Local display: Mechanical indicator (standard) Digit display: 4 digit flowrate 8 digit totalizer Protection class: Ip 65 Intrinsically safe, eex ia iic t5 Explosion proof, ex d iib t6 Pressure drop: 0.07 ~ 0.7 kg/cm2 Standard
Aliavtx avf7000 is a vortex flowmeters based on von karman theory of vortices generated by a bluff body in the pipe. The number of vortices are linearly proportional to the volumetric flow in the pipe. The avf7000 is versatile flowmeter widely used for gases, steam & liquid applications. There are no moving parts and comes with either Flange or wafer connection. Standard configuration comes with local indication for flowrate and total flow as well as a 4-20ma output function output. The electronics are designed to filter out erroneous signals as well as noise due pipe vibration. Features Simplified setup and diagnostic functions. Auto. Temperature & pressure compensation 4-20 ma and pulse outputs, user selectable. A very wide selection of sizes. Wide temperature range of up to 420 deg. C. Non-volatile memory for setup and calibration. Specification Size:10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500mm Material: Stainless steel 301 / 304 / 316 Accuracy: Liquid:+/- 0.7% of reading Gas & steam:+/- 1.0% of reading Process connection: Flange / wafer Flanges type: Jis 10k / jis 20k / jis 40k Ansi 150# / ansi 300# / ansi 600# Din pin 10 / pn 16 / pn25 / pn 40 Temperature: -40 ~ +280 deg. C (standard) -40 ~ +420 deg. C (optional) Protection: Ip 65 Explosion proof, exd iic t6 Intrinsically safe, e ex ia iic t4 Local display: 4 lines lcd 4 digit flowrate 8 digit totalizer Communication: Rs485 Standard
SFY-60C Product attributes 1.Small in size and light in weight 2.Rapid and accurate in detection 3.Easy to operate 4.Red numeral tube used in the displaying instrument 5.Widely used 6.Available to computer and printer connection Our Products SFY infrared moisture meter is a new,rapid moisture detecting instrument based on thermal gravimetric theory While sample products are weighed by infrared moisture meter,the meter is Infrared Heating Unit and Water Evaporating Channel dry the sample products rapidly.During the process,moisture meter continuously measure and display the moisture content lost by the samples.The final numerical value is fixed and showed after the dry process is over.Compared with the traditional oven heating approach,nfrared heating has the advantage of achieving the maximum heating power within the minimum time span.Samples are dried under high temperature,which quickens the detecting time generally,a sample is moisture value is detected within several minutes.It is accurate in detection and easy to operate.Its displaying part is a red numeral tube with clear displaying results.The moisture meter can respectively display enumerated date of moisture,sample is initial and terminal data,detecting time span and temperature is initial and terminal data.Furthermore,the equipment is easily available for connection with computer and printer.Hence,SFY infrared moisture meter can be applied widely in most products which requires rapid moisture detection,ncluding medicine,cereals,seeds,tobacco,chemical,tea,food,meat textile and etc as well as in laboratory and manufacturing process in fields like agriculture and forestry,paper making.plastic or rubber making,textile and etc. Product is technical target: Weighing capacity:Generally:0~60g Specifically0~100g Minimum reading:0.005g Moisture readable: 0.01%
SFY-20 SFY-20 Product attributes 1.Small in size and light in weight 2.Rapid and accurate in detection 3.Easy to operate 4.Red numeral tube used in the displaying instrument 5.Widely used 6.Available to computer and printer connection Our Products SFY infrared moisture meter is a new,rapid moisture detecting instrument based on thermal gravimetric theory While sample products are weighed by infrared moisture meter,the meter is Infrared Heating Unit and Water Evaporating Channel dry the sample products rapidly.During the process,moisture meter continuously measure and display the moisture content lost by the samples.The final numerical value is fixed and showed after the dry process is over.Compared with the traditional oven heating approach,nfrared heating has the advantage of achieving the maximum heating power within the minimum time span.Samples are dried under high temperature,which quickens the detecting time generally,a sample is moisture value is detected within several minutes.It is accurate in detection and easy to operate.Its displaying part is a red numeral tube with clear displaying results.The moisture meter can respectively display enumerated date of moisture,sample is initial and terminal data,detecting time span and temperature is initial and terminal data.Furthermore,the equipment is easily available for connection with computer and printer.Hence,SFY infrared moisture meter can be applied widely in most products which requires rapid moisture detection,ncluding medicine,cereals,seeds,tobacco,chemical,tea,food,meat textile and etc as well as in laboratory and manufacturing process in fields like agriculture and forestry,paper making.plastic or rubber making,textile and etc. Product is technical target: Weighing capacity:Generally:0~90g Minimum reading:0.001g Moisture readable: 0.01%
The adp9000 offer of configurations for differential, gas, absolute vacuum liquid-level measurements including integrated solutions for pressure, level and flow. Features Updating time of output current in 200 ms Improved performance, increased accuracy, greater stability Two years stability of 0.2% 0.075% accuracy Parameter setting by local keypad or rs485 communication port 4-20 ma output plus direct digital hart communication Automatic zero calibration by push button Explosion proof and weather proof housing Specification Process fluid: liquid, gas of vapor Application: differential pressure, gauge pressure, absolute pressu Measuring range:0 - 0.25 kpa ~ 0 - 1.5 kpa ( minimum ) 0 - 4.0 mpa ~ 0 - 25.0 kpa ( maximum ) Accuracy:+/- 0.75% of span Material: Flange/adapters: stainless steel 304 / stainless steel 316 Drains/vents: stainless steel 304 / stainless steel 316 Diaphragms: stainless steel 316l / hastelloy b /hastelloy c / monel / tantalum Wetted o-rings: Buna n / viton / ptfe Bolts & nuts: carbon steel / stainless steel 316 Mounting bracket: carbon steel / stainless steel 304 / 316 Name / tag plate: stainless steel 304 / stainless steel 316 Converter housing: low copper cast aluminum alloy with polyurethane, light blue paint Enclosure:ip67 ( standard )/intrinsically safe eex ia iic t5 ( standard )/ex Standard
The max :45.000rpm 4.5kg 25cm*30cm*28cm
Depth of Investigation v 400 meters a. Transmitter 1) Constant Current Selected automatically depending on ground conditions Max. Current 500mA Min. Current 1mA 2) Voltage (Max) 500 V (1000 Vpp) 3) Power 40W b. Amplifier Voltage Measurement Input Impedance 10 M Ohm Input Range 0-200V Precision + 0.05 mV Noise Rejection 95 dB at 50-60 Hz c. Resistance Measurement Apparent R Range m Ohm, Ohm, K Ohm Apparent R Precision 0.02 m Ohm at 500 mA d. System Data Cycle time 12 seconds Accuracy 2% Diagnostic display 9 codes Temp. Range 0 v 50 degree c e. Power Source 12 Volt, 12 Ah Rechargeable Battery Measuring capacity 2000 readings at 20 mA 200 readings at 500 mA f. Weight 12.5 Kg g. Dimensions L 400mm X W 225mm X H 330mm Weight 20 kg of instrument Additional Accessaries 60-80 Kg.
Features: 1. Galvanised roller surface,more enduring 2. With air cell lift convenient for car drive out 3. With clamp wheel prevent car scrape 4. High intensity bench 5. Free of maintenance Parameters: 1. Max Speed: 120Km/h 2. Max Load: 3t 3. Air pressure: 0.8Mpa Measure Parameters: 1.Speedometer Dimensions:(l*W*H) 2500 X 750 x 350mm
Features and benefits Range up to 8m/12m 6 mm range accuracy Easy remote operation, diagnosis and adjustment with KEY/LCD or PC Low processing power Capable 2-wire, loop powered, intrinsically safe inner temperature compensation to ensure accuracy of measurement Non-contact measurement Easy mounting via 1¿÷ NPT Low cost Application Continuous, non-contact level measurement in fluids, pastes, sullies and coarse bulk materials Characteristics Measuring Range Solids applications: 4m/6m (transducer dependent) Liquid applications: 8m/10m (transducer dependent) Measuring Resolution 2mm Accuracy 0.25% of range or 6mm, whichever is greater Max. Pulse Frequency 43.5KHz Operating Temperature -20..+80í+ Operating Pressure 0.7..3 mbar Power Supply 15..30V Power Consumption 51 mW ... 800 mW PCB Size Driver board(Ñ+:84mm), Main CTL board(Ñ+:80mm) PCB Material FR4 LCD Size 128*64dot Description ANL-4012 Ultrasonic Level Measurement Instruments use sound waves to determine level. A piezoelectric crystal inside the transducer mounted on top of the tank converts electrical pulses into sound energy that travels in the form of a wave at the established frequency and at a constant speed in a given medium. The sound waves are emitted in bursts and received back at the transducer as echoes. The Ultrasonic Level Measurement Instrument measures the time for the bursts to travel down to the reflecting surface and return. This time will be proportional to the distance from the transducer to the surface and can be used to determine the level in the tank. Ultrasonic systems are accurate within a range of approximately 8m. A typical installation consists of two parts: A Transducer, consisting of both a transmitter and receiver. Ultrasonic energy is transmitted from the í¦headí¦ in the direction of the liquid surface. When the ultrasonic waves contact the surface, they are reflected back to the receiver in the head. Electronics, which produce, control and time the ultrasonic pulses which are transmitted and received by the head. The electronics also transmit control signals to remote monitoring devices such as displays and process control systems.
Product Description Major technical data: Accuracy class: 1.0 Power consumption: 20 years. Main functions: 1) Measurement of 50hz for 3-phase active power 2) 4 tariffs and 8 time periods for user's option 3) RS 485 communication functions 4) Manual and remote control program, and remote-metering functions 5) To record the parameters automatically through CMRI. Features: 1) High accuracy, reliability, overload capability 2) Low power consumption 3) Smt technology and re-flow soldering technology 4) Light weight, small size, easy to install. Model: DTSF318/DSSF318 Standard: IEC 62052-11 IEC 62053-21 IEC 62056-21 Productivity: 100.000pcs/year.
DEM031 single phase electronic multi-rate watt-hour meter Application Type DEM031 single phase DIN rail watt-hour meter is a kind of new style single phase electronic multi-rate watt-hour meter, energy data display adopt 7 digits wide temperature type crystal display, with many functions of multi-rate (time-of use) energy measurement, infrared carrier wave communication and RS485 serial port communication reading meter, etc. The meter completely accord with relevant technical requirements of class 1 and class 2 single phase energy meter stipulated in National standard GB/T17215-2002 and international standard IEC61036. it has following features: Good reliability, small volume, light weight, specious nice appearance, convenient installation, etc.1. May select 35mm DIN rail installation or installation on the board. 2. Have 3 tariffs, 12 daily period of times, may select single tariff function in weekend. 3. Inner emplaced clock, after power cut down, the message is preserved forever, inner emplaced spare batteries and free of maintenance. 4. The direction of electric power can be distinguished automatically, accident is checked automatically. 5. Infrared carrier wave communication and RS48 5 serial port communication, meter is set up by program and password is protected. Technical parameters Type Accuracy Rated voltage) Rated current A) Starting Current Insulation Performance DDSF977(DEM031) Class 1 220V 2.5(10),3(15),5(30),10(50),15(90),20(100),5(40),5(100) 0.4%lb AC voltage 2KV for 1 minute impulse voltage 6kv DDSF977(DEM031) Class 2 220V 2.5(10),3(15),5(30),10(50),15(90),20(100),5(40),5(100) 0.5%lb AC voltage 2KV for 1 minute impulse voltage 6kv
Model:tc-2010 Control mode:dc0~+10v / 4~20ma Abalog input:display signal o/p dc0~+10v Tension detector input: euntay tension detector lms-005 ~ lms-200 Display typeíg2 rows x 5 characters of led Tension displayíg0.1~1999 kgf Indicatorígkgf unit Numeral setígí¦/ í+ key Tension setígí¦/ í+ key Parameter setígí¦/ í+ key Weight: ~0.8kg Size: 96 x 94 x 145mm
DEM101 three phase electronic prepayment watt-hour meter Application 1. After power cut down, data reserved forever, The direction of electric power can be distinguished automatically, and has function of anti-stealing electricity. 3. May select many kinds of IC card, have IC card with code and data against false. 4. May select 6 digits LED display or 7 digits LCD display. 5. May select payment controls by kWh or money. Technical parameters Name Type Accuracy Rated voltage) Rated current A) Connection Mode Three phase four wire electronic prepayment watt-hour mete31(2),31.5(6),33(6) Input through current transformer Three phase four wire electronic prepayment watt-hour meter DTSY223(DEM101) Class 1 3380/220 35(25),310(50),315(60),320(80),320(100) Directly input Three phase three wire electronic prepayment watt-hour meter DSSY223(DEM101) Class 1 3380 31(2),31.5(6),33(6) Input through current transformer Three phase three wire electronic prepayment watt-hour meter DSSY223(DEM101) Class 1 3380 35(25),310(50),315(60),320(80),320(100) Directly input
Operating temperature 0ípC ---40ípC Operating humidity Relative humidity 20%---80% Display character 0.56 í¦highlightedí¦ LED red character (options: green and blue) Installation method Built-in type Appearance sizes 96mmí-48mmí-77mm Tapping sizes 90mmí-45mm Carton
Operating temperature 0ípC ---40ípC Operating humidity Relative humidity 20%---80% Display character 0.56 í¦highlightedí¦ LED red character (options: green and blue) Installation method crown bar clamping type Appearance sizes 74mmí-32mmí-70mm Tapping sizes 70mmí-28mm Carton
Operating temperature 0ípC ---40ípC Operating humidity Relative humidity 20%---80% Display character 0.56 í¦highlightedí¦ LED red character (options: green and blue) Installation method Built-in type Appearance sizes 79mmí-42.5mmí-25.5mm Tapping sizes 76mmí-39mm Carton
Operating temperature 0ípC ---40ípC Operating humidity Relative humidity 20%---80% Display character 0.36 í¦highlightedí¦ LED red character Installation method Built-in type Appearance sizes 48mmí-26mmí-22mm Tapping sizes 47mmí-23mm Carton