Depth of Investigation v 400 meters
a. Transmitter
1) Constant Current Selected automatically depending on
ground conditions
Max. Current 500mA
Min. Current 1mA
2) Voltage (Max) 500 V (1000 Vpp)
3) Power 40W
b. Amplifier
Voltage Measurement
Input Impedance 10 M Ohm
Input Range 0-200V
Precision + 0.05 mV
Noise Rejection 95 dB at 50-60 Hz
c. Resistance Measurement
Apparent R Range m Ohm, Ohm, K Ohm
Apparent R Precision 0.02 m Ohm at 500 mA
d. System Data
Cycle time 12 seconds
Accuracy 2%
Diagnostic display 9 codes
Temp. Range 0 v 50 degree c
e. Power Source 12 Volt, 12 Ah Rechargeable Battery
Measuring capacity 2000 readings at 20 mA
200 readings at 500 mA
f. Weight 12.5 Kg
g. Dimensions L 400mm X W 225mm X H 330mm
Weight 20 kg of instrument Additional Accessaries 60-80 Kg.
Supplier: Earth resistivity meters, geophysical equipments digital resistivity meters, aquameter CRM
Supplier: Instrument transformer, metering cubical & isolator, electrical distribution line parts, led & earthing material
Services: Manufacturer
Function random phase measurement, AC current and leak current measurement, AC Voltage detection, distinguish the inductive circuit and capacitive circuit, sequence of three-phase voltage detection and connection group of transformer detection, etc. Power supply DC9V alkaline dry battery LR6f-6 continuous duty :300h LCD 3-1/2 LCD display Dimension Width *length* thick·ª92mmf-192mmf-50mm LCD dimension Display domain·ª64mmf-54mm ·+font high·ª40mm Clamp mouth ¬+7.5mm ·+¬+40mm lectotype·¼ Measuring range phase·ª0~360fp·+current·ª0~200mA/2A/10A·+voltage·ª0~20V/200V/500V resolution phase·ª1fp·+current·ª0.1mA·+voltage·ª0.01V Measurement accuracy ·+50Hz,23f¦f+1f¦·+40-60%RH·¼ phase·ªf+3fp current·ªf+1%f+2dgt Voltage·ªf+1.2%f+2dgt line voltage Line test under AC500V Sampling speed About 3 times /s Signal frequency sine wave 45Hz~55Hz ¬-=0.05 Data hold Data holding function·ªdisplayed by fªDHfª symbol Back light function Blue back light ,suit for dark occasion Automatic shutdown After starting up 15min·+it shutdown automatically to reduce battery consumption Battery voltage When battery voltage is low ,battery low voltage symbol will filker to remind replacing battery; Quality Core about590g·+with battery·¼·+long flat nose current pliers about ·ª175gf-2·+big round tongs clamp·ª120g Work temperature and moisture -10f¦~40f¦·+85%rh below Storage temperature and moisture -20f¦~60f¦·+70%rh below Driving point impedance AC voltage driving point impedance·ª2M¬+·+when test phase U1-U2·ª40K¬+ Insulation intension fª10M¬+9·+Between wire of meter and crust·+two voltage input port·¼ Voltage bear Between port of voltage input and box, split core type currenttransformator and clamp handle& winding coil: 1000V/50Hz, 1min experiment can be reach when sine wave AC voltage 500V/50Hz between port of voltage input. 92*192*50(mm)
Features: Widely applied in ground resistance measurement, loop resistance measurement With optional function of RS232 interface data upload No need to disconnect the ground wire from the ground net Without auxiliary electrode High accuracy and resolution With data memory Automatic power off Specifications: Clamp size: 65 x 32mm Resistance range: 0.01 to 1,200ohm; With automatic shifting Resistance resolution: 0.001ohm; Data memory: 99 sets Alarm setting: 1 to 199ohm; and buzzer alarm Quick boot: in 0.5 second With lower consumption.
Earth Resistance Tester: Model: ETCR2100+(basal) Category: Ground Resistance tester Earth Resistance Tester (ETCR2100+)-Illustration: ETCR 2100+ of Pincers Earth Tester, in the measurement of a grounding system with loop current, does not require breaking down the grounding wire, and need no auxiliary electrode. It is safe, fast and simple in use. 1.Wider range: 0.01Ñ+-1200Ñ+ 2.Stored data: 99 groups. 3.Resistance Resolution: 0.01Ñ+ 4.Size of Jaw: ¬¬32ú¿mmú¬ 5. Sound and light alarm, "beep - beep - beep -" alarm sound. 6. Breakthrough in self-test the boot a long time to wait, start immediately into the test. 7. Breakthrough relay self-test mode, using the most advanced processing algorithms and digital integration technology, a fully intelligent. 8. Break the old product to heavy issues, more in line with characteristics of handheld devices. 9. The new design, panel 6 button operation, the performance through. 10. Lower power consumption: Maximum operating current not exceeding 50mA. 260*90*66(MM)
Main features:1. 2/3/4-wires measurement of earth resistance, soil resistivity, earth voltage, , ac voltage;, 2.Measurement range: earth resistance: 0.00î©-30.00kî©; 0~600v, soil, resistivity: 0.00î©m-9000kî©m; 3. Data upload: rs232 interface, 4.Date storage:300 sets, model no:mewoi4000c, name:mewoi4000c-earth ground resistance/soil resistivity tester, electrode distance range:can be set 1m-100m, low power consumption:standby:1. About 20ma (backlight shut off), 2.Boot and with backlight: about 45ma, (25ma without backlight), 3.Measurement: about 100ma, (backlight shut off)
DDS22 Single-phase Electronic Watt-hour Meter adopts special large-scale integrated circuit, high-performance parts as well as advanced SMT technology. Therefore, the meter is characterized with high accuracy, tamper-proof function, high anti-interference, and long service life. The meter is easy to operate and can meet the customers' requirements well for its reasonable design. It is the optimum product for customers and public utilities. Functions and Characteristics: Accuracy Class: 1.0class The meter adopts special anti-magnet impulse meter reading mechanical register to prevent strong disturbance form external AC, DC magnetic field. Flat error curve, stable for temperature and time, and reliable. To cumulate both direct and reverse energy, prevent tamper of reversal of lines. Light weight, reliable structure. Easy to be handled and installation. Anti-tamper in condition that load is connected between the line and the earth. The meter can also prevent U ring short circuit and other tampers. Low consumption: ≤ 0.6W Distant-motion-width-determination pulse output and multifunctional output ports . 20units/Pack
Residential Diaphragm Gas Meter ITRON (MID approved) Steel Version Basic Features 3 Compact size: 1.2 dm cyclic volume Range: G1.6, G2.5, G4 EN 1359 & O.I.M.L compliance Design Long -term accuracy & safety Ready for remote reading & data management Quality World-class, ISO9001 certified, European Engineering and Manufacturing APPLICATION The ITRON, with an installed base of over 30 million units, is a versatile meter that makes it the preferred choice of many large utilities world-wide. METROLOGY The ITRON meets O.I.M.L, EN 1359 and MID (certificate delivered by the LNE), and more than 25 national metrological standards (DVGW,NMI Class 1....). Its design and the careful choice of materials enable the ITRON to meet the highest demand in international markets in terms of accuracy and long-term stability. During the preliminary test controls on the sonic nozzle test benches, all meters are tested at Qmin, 0.2 Qmax and Qmax. OPERATING PRINCIPLE The ITRON is a positive displacement diaphragm gas meter with a stand-alone twin chamber measuring unit. The twin chambers are each fitted with a flexible and gas-tight diaphragm which is moved by the differential between the inlet and outlet pressure. The Gas enters one side of the diaphragm pan while on the other side it comes out through a separate port on the valve. When one side is full, the rotating mono-valve moves on to the next position, allowing the gas to fill the empty side. A transmission gear and a mechanical coupling or stuffing box transfer the reciprocating motion to the mechanical retrofitable index. The measuring unit is housed in a robust gas-tight casing. CONSTRUCTION With its casing in steel, high protection against corrosion is ensured by 500 hours salt fog spray test resistant cataphoresis treatment. The aluminum version can withstand up to 1000 hours salt fog spray test. The extreme strength of the case joint is achieved by rolling the belt & compressing the flanges into contact with a sealant applied between the faces. This forms a joint which is both gas-tight and fire- resistant. MEASURING UNIT The achievement of the fixed stroke mechanism is the result of precision and high quality automation, and eliminates the need for an adjustable tangent. This confines all registration adjustments to the accessible change wheels behind the index. The long life synthetic diaphragms, coupled to the well-proven movement design, combine to give excellent stability and accuracy during the whole life of the metre. All materials have been selected for their superior resistance to chemicals and gas. The valve and the grid, thanks to a special Bakelite formulation, enjoy high gliding properties and are protected against premature wear. Finally, a back-run stop prevents the metre from running backwards in case of tampering. INDEX The metres are available with metric or cubic inch indexes. They come with a permanent magnet for pulse generation and can be retrofitted with a pulse transmitter. Ip54 and Ip67 versions are available for specific environments. QUALITY ASSURANCE Quality assurance procedures- such as ISO 9001- and strict controls throughout the manufacturing process ensure a very high quality level. APPLICATION The ITRON, with an installed base of over 30 million units, is a versatile meter that makes it the preferred choice of many large utilities world-wide. METROLOGY The ITRON meets O.I.M.L, EN 1359 and MID (certificate delivered by the LNE), and more than 25 national metrological standards (DVGW,NMI Class 1....). Its design and the careful choice of materials enable the ITRON to meet the highest demand in international markets in terms of accuracy and long-term stability. During the preliminary test controls on the sonic nozzle test benches, all meters are tested at Qmin, 0.2 Qmax and Qmax. OPERATING PRINCIPLE The ITRON is a positive displacement diaphragm gas meter with a stand-alone twin chamber measuring unit. The twin chambers are each fitted with a flexible and gas-tight diaphragm which is moved by the differential between the inlet and outlet pressure. The Gas enters one side of the diaphragm pan while on the other side it comes out through a separate port on the valve. When one side is full, the rotating mono-valve moves on to the next position, allowing the gas to fill the empty side. A transmission gear and a mechanical coupling or stuffing box transfer the reciprocating motion to the mechanical retrofitable index. The measuring unit is housed in a robust gas-tight casing. CONSTRUCTION With its casing in steel, high protection against corrosion is ensured by 500 hours salt fog spray test resistant cataphoresis treatment. The aluminum version can withstand up to 1000 hours salt fog spray test. The extreme strength of the case joint is achieved by rolling the belt & compressing the flanges into contact with a sealant applied between the faces. This forms a joint which is both gas-tight and fire- resistant. MEASURING UNIT The achievement of the fixed stroke mechanism is the result of precision and high quality automation, and eliminates the need for an adjustable tangent. This confines all registration adjustments to the accessible change wheels behind the index. The long life synthetic diaphragms, coupled to the well-proven movement design, combine to give excellent stability and accuracy during the whole life of the metre. All materials have been selected for their superior resistance to chemicals and gas. The valve and the grid, thanks to a special Bakelite formulation, enjoy high gliding properties and are protected against premature wear. Finally, a back-run stop prevents the metre from running backwards in case of tampering. INDEX The metres are available with metric or cubic inch indexes. They come with a permanent magnet for pulse generation and can be retrofitted with a pulse transmitter. Ip54 and Ip67 versions are available for specific environments. QUALITY ASSURANCE Quality assurance procedures- such as ISO 9001- and strict controls throughout the manufacturing process ensure a very high quality level. Prepaid Gas Meter Sensus Meters satndars
Supplier: Analog Panel Meters, Protector Relays, Current Transformers, Shunts, Cam Switches, Digital Panel Meter, Multifunction Meters, Battery Charger, Transducers, Isolators, Power Quality, Power Supply, Paperless Recorders, Temperature Controller, I/o's & Converters, Digital Multimeter, Clamp Meters, Insulation Testers, Energy Management System, Accessories, Earth Testers, Synchronising Unit, Genset Controllers, Automatic Power Factor Controllers