Manufacturer: Siemens turbines Condition: used - guaranteed power: 53.570 KW - vapour pressure alive: 94,00 bar - live steam temperature: 518,00 - live steam flow: 189.02 t/h - inlet thermal load flow: 647,752,638 kJ/h - socket pressure a3: 17,581 bar - socket flow rate a3: 13,490 t/h - thermal load flow a3: 40,812,646 kJ/h - socket pressure a2: 7,292 bar(a) - outlet flow a2: 18,50 t/h - socket pressure a1: 1,181 bar(a) - tap flow a1: 14,54 t/h - heat load flow a1: 37,296,554 kJ/h - exhaust pressure: 0,107 bar(a) - turbine rotation: 6,415.4 rpm - service factor: 1,1 (over Pe) - input rotation: 6,415.4 rpm - output rotation: 1800 rpm - change effective: 284.2kN.m 1800rpm
Steam turbines, turbo reducers and turbo generators.