1.Product description Six-channel current output, six-channel voltage output, six-channel share of dc current, six-channel dc voltage output, eight pairs of binary input, four pairs of binary output. 2.Features Integration in the host crystal 8.4 inches true color, light weight and easy to carry Built-in high-speed high-performance industrial computer, embedded operating system, running a stable and reliable also be connected pc testing Panel embedded user-friendly buttons can also be an external keyboard, mouse High-precision dac to 12 road, simultaneous output to ensure that waveform fitting of high precision, good linearity Matching electromagnetic compatibility components, can improve on-site anti-electromagnetic interference, protection devices can be connected electromagnetic compatibility tests Analog output of the front panel, switch the amount of terminal design in the upper cover, all the wiring does not affect the operation of the panels and test parameters of the surveillance Exterior appearance of cabinetImported electromagnetic compatible cabinet, which is made of high-grade all aluminum alloy extruded section and has fine appearance, is selected. Dimension of cabinet: length¡ñwidth¡ñheight¡@360mm ¡ñ195mm ¡ñ365mm Weight of cabinetWeight of host machine ¡@¡@¡@¡@¡@¡@¡@¡@¡@ ¡@16.6kg
Features Troubleshoot real-time: Analyze the trends using the cursors and zoom tools-even while background recording continues. Automatic Transient Mode: Capture 200 kHz waveform data on all phases simultaneously up to 6 kV Measure all three phases and neutral: With included four current probes System-Monitor: Up to ten power quality parameters on one screen according to EN50160 power quality standard View graphs and generate reports: With included analysis software Logger function: Configure for any test condition with memory for over 400 parameters at user defined intervals. Mains signaling: Measure interference from ripple control signals at specific frequencies Inrush mode: For troubleshooting nuisance circuit breaker tripping. AutoTrend: Every measurement you see is always automatically recorded, without any setup. Fully Class-A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard. Battery Life: Seven hours operating time per charge on NiMH battery pack High safety rating: 600 V CAT IV/1000 V CAT III rated for use at the service entrance • Comparing to online power quality analyzer, E6000 handheld type with small size, light weight, easy for the engineer to carry and carry out to survey work whenever and wherever. • Easy to wiring • It can operate directly to the line under test under the circumstances that the Power Grid without interrupt. • Multi-range current switching • based on actual demand, the different range of current clamp can be replaced to improve measurement accuracy. Applications Frontline troubleshooting - quickly diagnose problems on-screen to get your operation back online Predictive maintenance - detect and prevent power quality issues before they cause downtime Quality of service compliance - validate incoming power quality at the service entrance Long-term analysis - uncover hard-to-find or intermittent issues Load studies - verify electrical system capacity before adding loads Energy assessments - quantify energy consumption before and after improvements to justify energy saving devices. Specifications Measurement Items Be measured Type of measurement RMS Voltage Voltage RMS Current Current Frequency Deviation Frequency Three-phase Unblanced Voltage, Current Voltage fluctuations Voltage Flicker Voltage Harmonics and inter-harmonics, higher harmonic Voltage, current Power Active, reactive, apparent power factor Event log Transient pulse, the voltage rise, voltage sags, voltage interruption, the impact of current, frequency of abnormal Input parameter Measuring circuit 1P2W, 1P3W, 3P3W, 3P4W The fundamental frequency of the measuring circuit 50Hz/60Hz Number of input channels Voltage, current, 4 Measurement range Voltage Measurement Range: Nominal value: 100V, 230V, 400V, maximum 1000V Current measurement range: Depending on the current clamp, current clamp the output voltage signal, the maximum voltage: 10V peak Environmental security parameters Use of the environment 0 ° C to +45 ° C, humidity 90rh% Storage environment -20 ° C to +50 ° C, 95RH% humidity (non-condensing) Power input voltage +100VAC ~ +240VAC Electromagnetic Compatibility Level 3: GB / T 17626.2-2006 Electrostatic Discharge Immunity Level 3: GB / T 17626.3-2006 RF electromagnetic radiation the Immunity Level 3: GB / T 17626.4-2008 electrical fast transient burst immunity Level3: GB / T 17626.5-2008 surge (impact) Immunity Level 3: GB / T 17626.8-2006 frequency magnetic field immunity Level 3: GB / T 17626.9-1998 Pulse magnetic field immunity Level 3: GB / T 17626.12 -1998 Oscillatory waves immunity Environmental reliability GB/T 2423.1-2008 low temperature GB/T 2423.2-2008 high temperature GB/T 2423.4-2008 alternating hot and humid GB/T 2423.5-1995 impact GB/T 2423.10-2008 vibration GB/T 2423.22-2002 temperature changes Dustproof, waterproof IP20(GB 4208-93/IEC 529:1989) Security 500V/10M,2KV:GB/T 15479-1995 External interface parameters USB Device 1 The upload power quality data TF card to expand storage 1 Built-in capacity Optional, up to 8G Battery 1 4500mAh Ni-MH battery LCD 1 26 million color 5.6-inch LCD screen with a resolution of 640 * 480 Voltage and current measurement interface 8 Test voltage and current input port Frequency Measurement method 10 waveform (50Hz) the calculated frequency Display Display of a channel frequency value Measuring range / resolution 50.0000Hz/0.0001Hz Measurement bandwidth 42.5000~57.5000Hz Measurement accuracy ±0.001Hz 1/2 rms voltage 1/2 rms, current Measurement method Once every two cycle operations, a waveform operations per cycle to take 1/2 cycle Sampling Frequency 200K Measuring range / resolution 120V/0.01,230V/0.01,400V/0.01,Based on the use of current clamp Measurement accuracy 0.1% of the nominal voltage RMS voltage Measurement method 10 waveforms (50Hz) the operator Display Per channel RMS voltage Sampling Frequency 200K Measuring range / resolution 120V/0.01,230V/0.01,400V/0.01 Measurement accuracy 0.1% of the nominal voltage RMS voltage Measurement method 10 waveforms (50Hz) the operator Display Current per channel RMS Sampling Frequency 200K Measuring range / resolution Based on the use of current clamp Measurement accuracy 0.1% of the nominal voltage Harmonic voltage, harmonic current Measurement method According to IEC61000-4-7, the magnitude of the analysis window 10 cycles Window points Every 10 cycles of 5120 points Display Histograms, tables Sampling Frequency 200KHz Number of measurements 0~50 Measuring range / resolution 120V/0.01,230V/0.01,400V/0.01 Measurement accuracy voltage harmonics greater than 1% of the nominal value: Error is less than 1% rdg voltage harmonics less than 1% of the nominal value:Error is less than 0.05% rdg the nominal voltage current harmonics greater than 3% of the nominal value: the error is less than 1% edg current harmonics is less than 3% of the nominal value:Error is less than 0.05% of the nominal voltage interharmonic voltage interharmonic current Measurement method According to IEC61000-4-7, the magnitude of the analysis window 10 cycles Window points Every 10 cycles of 5120 points Display Form Sampling Frequency 200KHz Number of measurements 1~16 Measuring range / resolution 120V/0.01,230V/0.01,400V/0.01 Measurement accuracy voltage harmonics greater than 1% of the nominal value: Error is less than 1% rdg voltage harmonics less than 1% of the nominal value:Error is less than 0.05% rdg the nominal voltage current harmonics greater than 3% of the nominal value: the error is less than 1% edg current harmonics is less than 3% of the nominal value:Error is less than 0.05% of the nominal voltage High harmonic voltage, high harmonic currents Measurement method Every 10 cycles of 5120 points Window points Every 10 cycles of 5120 points Display Form Sampling Frequency 200KHz Number of measurements 1 to 35 group Measuring range / resolution 120V/0.01,230V/0.01,400V/0.01 Measurement accuracy voltage harmonics greater than 1% of the nominal value: Error is less than 1% rdg voltage harmonics less than 1% of the nominal value:Error is less than 0.05% rdg the nominal voltage current harmonics greater than 3% of the nominal value: the error is less than 1% edg current harmonics is less than 3% of the nominal value:Error is less than 0.05% of the nominal voltage Active power, reactive power, apparent power Measurement method Active power: 10 cycles computing Apparent power: Valid values of voltage and current operations Reactive Power: apparent power, active power is calculated Display Real-time data display Sampling Frequency 200KHz Measuring range / resolution Determined based on the voltage and current range Measurement accuracy ±0.5%rdg Power Factor Measurement method Rms, current rms voltage, active power is calculated Display Real-time data display Sampling Frequency 200KHz Measuring range / resolution -1.0000~1.0000 Measurement accuracy ±1%rdg Voltage unbalance, current unbalance (negative and zero sequence) Measurement method when 3-phase 3-wire or 3-phase 4-wire, calculate by three-phase fundamental ingredients Display Voltage unbalance current imbalance Sampling Frequency 200KHz Measuring range 0.00%~100% Measurement accuracy Voltage unbalance: ± 0.5% Current imbalance: ± 0.5% Voltage fluctuations Measurement method Half-wave to calculate the mean square Display The fluctuation trends, real-time values of voltage fluctuation Sampling Frequency 200KHz Measuring range 0.00%~100% Measurement accuracy ±1% IEC Flicker Measurement Item The short flicker (PST), long flicker (Plt) Measurement method According to IEC61000-4-15 10 minutes PST continuous measurement, continuous measurement and calculation 2 hours Plt Display The flicker trends, Pst value, Plt Measuring range 0~20 Measurement accuracy ±5% The impact of current Measurement method Half-wave rms current exceeds the set value of the positive impact of current Display The impact of current waveform, the impact of the current maximum Measurement accuracy 0.10% Measurement method Temporary swell: half-wave rms voltage positive direction exceeds a set value, it is determine as Temporary swell temporary sag: Valid values are negative direction exceeds a set value, determine as temporary sag Short interruptions: half-wave RMS voltage exceeds the set value in the negative direction, the decision for an instant interrupt Display Temporary swell, sag, short interruptions waveform duration, amplitude etc. Measurement accuracy 0.10% Temporary swell, sag, short interruptions waveform duration, amplitude etc
Application It is suitable for power department, measuring department, quality control department, research units, and institutions of higher learning, and electric energy meter, power distribution terminals, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. Main Functions and Features To set up and take the load regulation of voltage, current, phase and frequency of the power factor; To be set to 2 ~ 128 times of the amplitude and phase harmonics, and it can be added to the base wave in every harmonic output; Voltage, current output a wide range, big power, high stability, waveform distortion degree is very small; To have strong with load ability, and take capacitive, sensibility, resistance of composite type load or load and load regulation is higher than 0.01% ; To apply the 32 bit MPU + DSP + FPGA, powerful flexible; To use hardware PID, fast response, the change of load will not cause output volatility; Industrial frequency waves as high as 50000 points a week of the wave kneading, signal output without filter, precise output waveform, the harmonic output precision, harmonic distortion degree is small; Range switching automatically; To use software calibration, simple operation, stable and reliable; To have the big screen, 320 x 240 LCD display, Chinese or English interface, operating simplely; To have perfect over-current, over-voltage, heat, a shorts-and-opens, overload protection, automatic failure detection; With RS232 interface, and PC connection; To take place machine software, it can be output through the PC software of program. Technical Data AC voltage output Range: 57.7 V / 100 V / 220 V / 380 V / 750 V, range switch automatically Adjust fineness: 0.01% RG Accuracy: RG is higher than 0.05% Stability: better than 0.01% RG / 1 min Distortion degree: better than 0.1% (not capacitive load) Output power: the rated each phase is 40 VA Full load regulation rate: less than 0.01% RG Full load regulation time: less than 1mS Temperature drift: 8 PPM / ¡æ Long-term stability: 60 PPM/year AC current output Range: 0.1/0.25 A / 0.5/1 A / 5 A / 10 A / 20 A / 50 A / 100 A, range switch automatically Adjust fineness: 0.01% RG Accuracy: RG is higher than 0.05% Stability: better than 0.01% RG / 1 min Distortion degree: better than 0.1% (not capacitive load) Output power: the rated each phase is 40 VA Full load regulation rate: less than 0.01% RG Full load regulation time: less than 1mS Temperature drift: 8 PPM / Long-term stability: 60 PPM/year Phase angle Adjusting range: 0 ~ 359.99 Resolution: 0.0 Accuracy: 0.03 Frequency Adjusting range: 40 Hz ~ 65 Hz Resolution: 0.001 Hz Accuracy: 0.002 Hz Temperature drift: 0.5 PPM / Long-term stability: 4 PPM/year Work power Single phase AC 22015% , Frequency 50/60 Hz. Volume and weight Size: 420 mm x 320 mm x 155 mm (long x width ¡Á high) weight: 12 kg Environmental conditions Working temperature: 0 ~ 40 Relative humidity: 85% Storage conditions: -30
Product description Gf102 single phase energy meter testing set used to test single phase energy meter. Adopt mature signal synthetic and power amplifier technology. High voltage and current output . Widely used in lab and field. Features Meter under testing: 1p2w Testing mode: active power, reactive power Test 3pcs or 2pcs meter synchronously Starting test and creeping test Reference standard and power source integrated, easy to carry. Measuring mechanical meter and electric meter Operating by manual keyboard or pc With shortcut key of normal test point, speed up testing Internal large capacity storage device for mass memory Local checking the testing result Overload, short circuit, open circuit protection With self-checking function Technical data Voltage Test voltage output (phase-neutral) 0v ¡v 264v Power of the voltage output Max. 30va , 15va Resolution 0.01% Accuracy 0.1% , 0.2% Stability 0.02%/120s , 0.05%/120s Distortion factor < 0.3% for linear resistance load Current Test current output 1ma ¡v 120a , 1ma ¡v 60a Power of the current output Max. 100va , 30va Resolution 0.01% Accuracy 0.1% , 0.2% Stability 0.02%/120s Distortion factor < 0.3% for linear resistance load Phase angle Range 0 -- 360¢x Resolution 0.1¢x Accuracy 0.2¢x Frequency Range 45hz ¡v 65hz Resolution 0.005hz Pulse output High frequency output(ch) 1.666¡ñ105 hz Low frequency output(cl) 5¡ñ10-5¡ñch Pulse input Input channel 3 Input frequency Max. 20hz Other Voltage supply 220v¡ó10% 50/60hz¡ó2hz Ambient temperature -10¢xc -- +40¢xc Relative humidity 35% -- 85% Dimensions (w¡ñd¡ñh) (mm) 445¡ñ440¡ñ180 , 410¡ñ220¡ñ150 Weight (kg) 18 , 9.5 Dimensions (w¡ñd¡ñh) (mm) 445¡ñ440¡ñ180 , 410¡ñ220¡ñ150 Weight (kg) 18 , 9.5
Brief introduction 1. Fast processor Cpu is msm7627 aa and the system adopts android 4.0 ics operating system. 2. Strong protection for bad environment It can apply to the bad environment, which can resist multiple dropping impact from 1.2m high; apply to ip65 protection grade with good water-proof and dust-proof effect; durable and long life span. 3. Visible 3.5 inch lcd in the sunlight It is 3.5 inch vertical screen lcd, 480*640 high resolutions; with pressure sensitive touch screen and semi permeable tft lcd readable display. Its particular non glare and reflective technology make the work in the wild sunlight more easy and convenient. 4. The storage capacity is big and extensible Tf card supports no less than 8g cards, which can basically satisfy regular information and data storage. It adopts portable change design. There is no need to open the tester and you can remove the battery with the knob. The battery capacity is as high as 6000 mah. 5. Advanced battery installation design and strong endurance Due to the lithium battery capacity of 6000 mah and low-power design, the duration will be more than 3 days under routine operation. 6. Multi-functional module integration --the built-in fixed network test module can do adsl test, lan test and modem emulation. --5 million pixels camera makes the image data collection convenient. --support bluetooth, which is convenient provide data transmission between any compatible electronic equipment. --built-in gps module can realize the position location. --support 1d/2d red light/ laser bar codes scan. 7. Reliable process design It adopts advanced manufacturing process which is reliable and convenient to assemble. Paper carton package.
Function and usage It can set with 5 different temperature spots to do heat sealing, select the optimal heat healing temperature, and can also set the same temperature to speed up the heat sealing. Instrument structure: The structure of the heat-sealing tester is composed of 4 parts: pneumatic drive system, heat-sealing equipment, temperature adjustment system and time adjustment system. Pneumatic drive system: It includes pressure gauge, guide stick, cylinder, pneumatic valve, pressure regulating handle and so on. You can pull the pressure-regulating handle outward, rotate to the right side to adjust the heat sealing pressure to a high value, and rotate to the left side to reduce it. After setting the pressure, please press the handle to the side of mainframe to lock the air pressure. Heating-seal device It is composed of the upper and lower heat-sealing sticks, of which the upper one is connected with a cylinder. There is an insulating plate in the upper part, which can prevent heat transmit to the cylinder. The heat-sealing stick is made of aluminum, and the center is heater. There is a silica gel plate in the upper part of the lower heat-sealing stick, which can mitigate pressure impact during heat sealing. Temperature measurement system was installed at the back of the heat-sealing stick. Temperature adjustment system: The upper temperature controller controls the temperature of upper heat-sealing stick, and the rear temperature controller controls the temperature of lower heat-sealing stick. The temperature can be set at will through adjusting the button on the dial plate. Time adjustment system: Time adjustment system: The heat-sealing time can be set at will through adjusting the button on dial plate. The setting scope of time is 0.01s to 999.9h. Press the foot switch under the manual state, and the heat-sealing stick will be pressed together. Under the automatic state, the press-fitting time of upper and lower heat sealing sticks are controlled by a timer automatically, it can automatically recover later. The unit of timer is 0.1 second in general. There is time adjusting button on the panel of the timer, and the heat-sealing time can be adjusted at will. Specifications Power : AC220V 50HZ Compressed air: 8kg/cm2 Heat sealing plane: 300mm10mm slick (With silicon pad in lower seal stick) Heat sealing temperature: room temperature 20~300C (Precision 1C) Heat sealing time: 0.01s~99.99h Heat-sealing pressure: 0~0.8Mp. Dimension: 700(L)mm400(W)mm540(H)mm Weight: Desktop 30Kg. 700mm(L)X400mm(B)X540mm(H)
St332b tester is multi-functional hand-held adsl2+ test instrument with small size, specially designed for xdsl line test (xdsl include: adsl, adsl2, adsl2+ readsl etc) and maintenance it provides xdsl test, pppoe dial test, dmm test, modem emulation, line voltage indication and so on. The tester adopts lcd display and menu operation which can display the test results directly and improve the xdsl broadband service greatly. Itf+s the best choice for the field operators of installation and maintenance. Key features: 1) Test objects: adsl2+; adsl;adsl2;readsl 2) Multifunction: physical layer test; modem emulation ; pppoe dial ; dmm test; browse ip address information; determine telephone line faults (line break or mix) 3) Judge the quality of service 4) Data memory capacity: 50 records 5) LCD display 6) Menu operation 7) Simple, portable and money-saved. 8) Telephone functions, can detect incoming call, built-in earphone and microphone (optional). 160*76*28(mm).
ST3200 OTDR (Optical Time Domain Reflectometer) is an intelligent optical fiber communication tester. This tester is easy to use and portable, which has a 3.5-inch color LCD touching screen. It also possesses events intelligent analysis and more user---friendly operation. It is an ideal test instrument for the fiber testing and troubleshooting. It can test the length of optical fiber and optical fiber cable attenuation coefficient. It can exactly display the loss distribution curve of the optical fiber and cable as well as the loss between two points and the joint loss. It also can test the distance between two points and the position of joint, fault point as well as breaking point. This tester has VFL (Vision Fault Locating) system. So it becomes convenient to test the fault location of jumper wire. Main functions: * Test the distance between two points and dynamically display the distance between two cursors * Test the loss between two points and the loss constant of the optical fiber and cable * Test the joint loss * Auto-optimization and quick response * Search for the event points automatically * The function of wave form storage: it can store the wave form data and test condition into the disk and the stored information also can display again. * Support the function of copy: it can copy the data file which is built in the internal disk into the U-disk directly. D, w, h: 200mm, 100mm, 60mm.
Brief introduction: St805 pon power meter is specially designed for pon network construction and maintenance which can be connected between olt nad ont. The voice, data, video signal online can be measured and displayed synchronously with this meter. Key features 1. Test the three wavelength of the pon network synchronously: 1490nm, 1550nm, 1310nm 2. Can test the burst mode signal of 1310nm 3. Can set the threshold value, upload data, calibrate the wavelength through management software. 4. Can save 1000 records and upload the records to the management software 5. Supply 10 groups threshold values 6. En menu display 7. Auto shut off backlit 8. Real-time display Technical specifications Standard wavelength: 1310(up); 1490(down);1550(down) Pasband(nm):1260f+1360; 1470f+1505; 1535f+1570 Range(dbm): -40f++10; -40f++10; -40f++20 Isolation.1310nm++db++: ; >40; >40 Isolation.1490nm++db++: ; >40; >30 Isolation.1550nm++db++: ; >40; >40 Accuracy: Uncertainty++db++:F+0.5 Polarization relevant loss(db++:
St230f tel line tester is a portable and intelligent line fault tester, which adopts advanced technologies such as intelligent cpu, ic & smt technology. It integrates various kinds of functions such as telephone and line performance test to be the one. The incoming call number display function is compatible with fsk/dtmf two types. Its particular function of dc/ac voltage test can test whether there is dangerous dc/ac high voltage in the line or not quickly and accurately in order to protect lineman from high voltage. The tester is designed following the human engineering theory with the appearance style like barbell, it can be put on the shoulder, the lineman can do other work using hands at the same time; besides, it can be hung in the tool belt of waist through the pothook, it is convenient to realize the talk function cooperate with the high quality earphone when the lineman is climbing or doing other things; the max working duration when the inside rechargeable ni-mh battery is fully charged is 7 hours; the shell is made of the new type of material and it resists water and shock. Features: 1. Cid function, FSK/DTMF compatibility 2. Dtmf applying to GB/T15279-94 3. Dialing number display 4. Checking wire pairs function 5. Low voltage warning, automatic power off and energy-save design 6. Handsfree 7. Small size, simple operation. Quantity no limited /case pack Dimensions(mm): 232-73-95 Weight kg: 0.5.
Features: With latest patented technology Safe and time saving: non-contact phase sequence detection Multipurpose: with live wire examination,simple power inspection, phase deficiency judgment, breakpoints finding and line maintenance Dynamic LED display Sensitive and reliable. Specifications: Voltages: 70 to 600V AC Dimensions to be clamped: diameter 18mm.
Features: Widely applied in ground resistance measurement, loop resistance measurement With optional function of RS232 interface data upload No need to disconnect the ground wire from the ground net Without auxiliary electrode High accuracy and resolution With data memory Automatic power off Specifications: Clamp size: 65 x 32mm Resistance range: 0.01 to 1,200ohm; With automatic shifting Resistance resolution: 0.001ohm; Data memory: 99 sets Alarm setting: 1 to 199ohm; and buzzer alarm Quick boot: in 0.5 second With lower consumption.
Parameters: - simulation and measurement: thermocouple signals J, K, T, R, S, B, U, L, E, N, with auto-compensation of terminal temperature, signals in thermocouple and thermostat system, resistance thermometer signals: Pt 100, Pt 500, Pt 1000, Ni 100, Cu 100, resistance signals from 10 up to 5 , voltages and currents in range: -11 V...+11 V and 22 mA...+ 22 mA - accuracy 0.025% - STEP and RAMP function, - led out 24 V terminals, - RS 232C interface, - available in the option for pressure calibration. The INMEL 60 calibrator is destined to check and control systems, industrial automatic control engineering devices such controllers, recorders, meters, etc. This instrument has the possibility to generate and measure signals from ten thermocouples, five thermometer resistances, four voltage ranges, two current ranges, two resistance ranges. Thermoelectric terminals have an internal temperature measurement and for this reason make possible the generation or measurement of thermoelectric signals with the compensation for the given thermocouple. In this working mode, a real thermocouple is added to thermoelectric measuring terminals, and compensation conductors to thermoelectric generating terminals. The calibrator ensures the simultaneous generation of the signal on output terminals and the measurement of the signal on measuring terminals, thanks to this feature the calibrator is suitable to check transducers. The INMEL 60 calibrator enables to check two-wire transducers. the used graphical display contains a lot of information on a screen with a good readability. The display ground-lighting, which can be switched off, is especially useful in conditions of an insufficient lighting. The internal supply from the battery enables the work not only in laboratory conditions but also on the object. The calibrator can also be used to the maintenance and servicing of industrial measuring instruments, systems and electronic equipment. Application: Checking and calibration: - measuring transducers controlled by a voltage or current signal, a thermoelement or resistance thermometer, - two-wire transducers, - temperature meters, - pressure transducers, - manometers, - measuring and control lines.
Technical parameters: - Voltage ranges from 200 V up to 1000 V, - Current ranges from 200 A up to 20 A, - Frequency ranges from 20 Hz up to 100 kHz, - Resistance from 1 up to 19 M, - Voltage accuracy from 35 ppm, - Current accuracy from 150 ppm, - Ample software, - High output load, - RS 232C , IEEE488 interfaces. The INMEL 7000 calibrator is device with very high precision and simultaneously high load, thanks that it pulls ones weight very well with checking modern type as well older types of meters. It is characterized elastic and open systemic structure. We offer varius version of this calibrator from very simple e.g the DC voltage calibrator up to full configuration : DCV, DCI,ACV,ACI and R. Thanks to ergonomic desc and rich internal software the INMEL 7000 calibrator is very handly. In calibrator INMEL 7000 used modern construction solution, in which used new generation of electronics elements of renowned worldwide companies. Thanks that ones received very good metrological parameters, reduced quantity of compnents, and in this way augment the reliability of this calibrator. Application: Checking and calibration: - AC and DC voltmeters, - AC and DC ammeters, - frequency meters, - measuring transducers, - ohmmeters.
Technical parameters: - Voltage ranges 0.2 do 1000 V, - Current ranges od 20 mA do 20 A, - Frequency ranges od 40 Hz do 5000 Hz, - Voltage and current accuracy DC 0.02%, - Voltage and current accuracy AC 0.05%, - Load carrying capacity 40 VA, - Serial interface RS232, USB, Ethernet. The INMEL 1000 calibrator was made on base of modern componenets of microprocessor technologies. Applicated technologies are comparable with technologies used by leading global companies.The INMEL 1000 calibrator characterize oneself the innovative structure of operation in range of output signals and operation of measuring and regulatory loop.For AC course possible is the synchronous operation with the main. This possibility influence on output parameters, reliability, comfort of work, the communication way with user and external devices. The calibrator INMEL 1000 fulfils directives of the European Union within the range safeties and the electromagnetic compatibility:The production of the INMEL 1000 calibrator does not create threats for environment. Application: Checking ang calibration: - AC and DC voltmeters, - AC and DC ammeters, - frequency meters, - measuring transducers.
Parameters: - voltage measure: 0 100mV, 0 10V, - current measure: 0-24 mA, - voltage generation: 0 100 mV, 0 10V, - current generation: 0 24 mA, - voltage accuracy: 0.02% + 2 digits, - current accuracy: 0.015% + 2 digits, - loop power output: 24V Calibrator INMEL 50 integrate generation and measurement function of electric signals, used in automatic industry. The main features of this devices is high accuracy and resolution of generating or measuring signals, friendly operation and large display. Application: Checking and calibration: - measuring transducers, - measuring and control lines, - current loop.
1.Available for encoding, and for setup of the address for each DMX512 decoder module (SC-DMX-00xH/L) of own company; 2.Available for one-time setup of different addresses for the DMX512 control system consisted of by SC-DMX-00xH/L(DMX-512 decoder module) of own company; 3.Available for transmission single and multiple channel DMX512 signal; 4.Available for scene function, and for independent setup of DMX512 Start code and value of each channel; 5.Support transmission of DMX512 testing signal by 40Hz or 20Hz; 6.Available for receiving DMX512 signal and for separate display of 512 channels and their respective Start code. Technical specifications: Brand name SC-DMX-512 Communication protocol DMX512/1990 DMX512 I/O RJ45*2 Display 16*4 large screen LCD Power supply input DC 9V Rated power
Dimension (LxWxH): 223*92*45mm Weight (W/OBattery): 185g Ambient Condition: below 30-80%RH (w/o condensation) Battery: 6F-22 9V Metal Test (Ref.Value): Steel pipe(Diameter¦Õ15) Test Depth 24mm Voltage Test (Ref.Value): AC110V Depth 20mm AC220V Depth 20mm Wood Test (Ref.Value): Wood Framing (up to 15mm). Each item in one Double Blister 6 pcs / inner; 24 pcs/ctn inner ctn size: 31.5*18.5*31.5cm ctn size: 65.5*39.5*33cm Gw/Nw: 9/8 Kgs.
ZY 6058 Tracking Index Tester A. Introduction: This device applies to lighting equipment , low voltage electric appliance, household appliances, electric appliances , electric tools ,electronic instruments, electrical instruments , information technology research and production and quality department, also suitable for insulation materials , engineering plastic . electrical connectors, auxiliary parts industry. B. Standards: IEC60112, GB/T 4207, UL746A . C. Main parameters: 1. Testing chamber size :60cm*95cm*90cm (DxHxW) . 0.5M³. 2. Testing voltage : continuously adjustable during 100-600V, digital display. 3. Electrode :2 piece of platinum electrodes, 2mm*40mm*5mm (DxHxW). 30 inclined plane . 4. Distance between electrodes : 4.0mm. 5. Droplet equipment : interval time of droplet is adjustable 6. Pressure on surface :1.0 7. Max electricity : 3A 8. Outsize :61cm(D)x120cm(W)x105cm(H).
DTDL-8110 Cablefault Test Set is an integrated set of Cablefault Detection and Location Devices. It is applicable for many types of power cable, communication cable and optical cable. It can accurately measure the distance of cablefault and locate the fault point. The system includes: 1) DTDL-8110 Mainframe. 2) DTDL-8032R Receiver. 3) RF Inductive Tracking Rod. 4) Potential Difference Locating Rack with 2 pins. 5) AF Stethoscope and Headphones (for Listening mode). 6) Grounding Pin.