copper cathode, copper rod, copper wire, aluminum scrap (6063,6061, taint tabor, wheel, talon, litho, radiator, UBC, tense, telic), aluminum ingots, copper scrap (mill berry . b. berry, birch, cliff), stainless steel scrap (201, 304, 316, 309, 310, 311, ), brass (gunmetal, sheets), lead (scrap, ingots, soft), zinc ( ingots, scrap), MS billets, cast iron scrap, iron scrap (HMS 1/2, LMS, railway track, shredded), dry battery ( plates, battery), plastic, tyre, urea.
Crusher & minerals:, iron ore, rock phosphate, phosphoric acid, dap, map, magnanese, gypsum, sulphur (iran), lime stone, iron ore, gabro aggregates, armor rocks, aggregates, armor rocks, filling materials, radiator, condenser, evaporator, refrigerant, coolant, heavy duty generators of:, caterpillar & perkins, (diesel, hfo & gas),, petroleum products:, sulphur 99.3 first grade (lump), bitumen (all grades), d2, jet fuel, methanol, lpg, naphtha, crude oil, diesel.Clearing & shipping
TI UNITS Reciprocating Water Chillers are available in two types of air cooled and water cooled in capacity range of 5 to 240 tons of refrigeration and compressor configurations of one to four. Evaporators and condensers are high efficiency shell and tube heat exchangers designed based on TEMA (Tubular Exchanger Manufacturers Association) standards. Safety controls installed on all units include high and low pressure cut-outs, compressor oil pressure safety cut-out, water anti freeze thermostat, water flow switch and evaporator entering water thermostat. Whatever mentioned above, are all chosen from the most recognized controls manufacturers in the air conditioning industry. Compressors are by DWM COPELAND and BITZER which happens to be one of the best and the most reliable brands. Raw materials such as copper tubes, fittings and valves are supplied by well respected manufactures. Electrical safety measures such as three phase controller and circuit breakers are available on all units. A fault detection system for the whole unit is available upon request. Microprocessor based PLC controller is also available as needed.
TI UNIT compact roof top chiller units are manufactured in type of air cooled in capacities of 5 to 360T.R. in one to four circuited configurations. In all TI UNIT compact roof-top chiller units the frames and body are from galvanized steel & stainless steel (316l) (option) the chassis made steel channel in appropriate thicknesses and all of units are completely painted in the proper thickness. Evaporators are high efficiency shell and tube heat exchangers, designed based on TEMA. Condenser of compact rooftop chiller unit made of plated coil, designed based on TEMA. Chillers with plate type heat exchangers are available upon request. TI UNIT compact roof top chillers can be designed to operate with R-22, R-407C and R-134a refrigerants. Safety controls installed on all units include high, oil and low pressure cut-outs, compressor safety cut-out, water anti freeze thermostat, water flow switch and evaporator entering water thermostat and compressor operation time logger. The above mentioned are all chosen from the most recognized controls manufactures in the air conditioning industry. Automatic condensing temperature control: A controller, factory installed on each unit automatically stages the condenser fans allowing the unit to start. With this controller the condenser fans start stage by stage. Raw materials such as copper tubes, fittings and valves are supplied by well-respected manufacturers. Electrical safety measures such as three phase controller and circuit breakers are, available on all units. A fault detection system for the whole unit is available upon request. Microprocessor based PLC controller is also available as needed. Suitable accessories make the chillers operable in all seasons according to the application requirements without any problems.
TI UNIT screw chillers are manufactured in two types of air cooled and water cooled in capacities from 50 to 560 T.R. in one to four circuited configurations. Evaporators and condenser Chillers with plate type heat exchangers are available upon request. For further related technical information, please send your inquiries to TI UNIT mfg. group. TI UNIT screw chillers can be designed to operate with R-22 and R-134a refrigerants. Bitzer screw compressors suitable for use with R-134a refrigerant are available in two versions (m.vr.1 & m.vr.2) which can be used in the chillers as required. Safety controls installed on all units include high and low pressure cut-outs, compressor oil level control safety cut-out, water anti freeze thermostat, water flow switch and evaporator entering water thermostat and compressor operation time logger. The above mentioned are all chosen from the most recognized controls manufactures in the air conditioning industry. Compressors are by Bitzer which happens to be one of the best and most reliable brands. Raw materials such as copper tubes, fittings and valves are supplied by well-respected manufactures. Electrical safety measures such as three phase controller and circuit breakers, are available on all units. A fault detection system for the whole unit is available upon request. Microprocessor based PLC controller is also available as needed. TI UNIT screw chillers are also available upon request for industrial applications in both Air Cooled and Water Cooled types; Suitable accessories make the chillers operable in all seasons according to the application requirements without any problems.
Car shampoo, tyre gel, car polish, air freshners, cleaning liquids, radiator coolant, car accessories.We will deliver our products to the end customer