Features and Benefits:
Ø Low profile aluminum body-light weight, easier to handle, provides an attractive, image enhancing appearance.
Ø Full hand insulator-protects both nozzle and vehicle, and insulates user's hands.
Ø Hold-open rack is available for full service application-the one hand control means easy setting to flow rate for customer convenience.
Ø Easily replaced spout-simply remove the spout retaining screw. Replacement provides and entirely new outlet check valve. Kits are available from TDW.
Ø Suitable for diesel, kerosene, gasoline and gasoline with ethanol blends.
Ø 100% Factory Tested.
Material
Body Aluminum
Lever and lever guard Duratuff
Main stem Extra hard stainless steel
Seals Buna-N, Viton
Technical Specifical
Working Pressure 0.2 Mpa
Auto Shut-off sensibility 0.1 second
Thread NPT/BSPT
Spout Outlet Diameter 15/16", 13/16"
Inlet Size 3/4"
Flow Rate 18-60 L/m(15/16"), 15-40 L/m(13/16")
Net Weight 1.15 KG
Color Options
Red, Green, Blue, Yellow, Orange, Black
1) Introduction:
Gasboardâ??5020 can be used for measurement of the concentration of automobile emission gas CO ,CO2 ,HC ,O2 and NO (optional), based on NDIR technology. This analyzer is designed with portable and smaller physical dimensions. The general application is for automobile emission check station or car repair garage.
3) Features:
.Proprietary Infrared(NDIR) gas sensor
.Can measure gas concentration of CO ,HC ,CO2 ,O2 ,NO (optional) simultaneously
.With 320*240 LCD real time display
.Air/fuel ratio calculation and display automatically.
.Auto-zero calibration with air
.Oil temperature and RPM interface.
.Plug in Printer optional.
.RS-232 interface and optional software.
Diesel vehicle exhaust gas analyzer (can also be used in gasoline vehicle), belong to customized products, non standard. Increase the reverse blowing system and filtering, purifying device. Can be used for the detection and analysis of diesel oil as fuel of vehicle exhaust emissions group points.
ã??Main technical parametersã??
exhaust gas analyzer
measuring range COï¼?0ï½?10.0 10-2(%) CO2ï¼?0ï½?20.0 10-2(%) HCï¼?0ï½?9999 10-6(ppm)
O2ï¼?0ï½?25.0 10-2(%) NOï¼?0ï½?5000 10-6(ppm)
oil temperatureï¼?18ï½?150 speedï¼?100ï½?20000rpm
resolving power COï¼?0.01% CO2ï¼?0.1% HCï¼?1ppmO2ï¼?0.01% NOï¼?1ppm
oil temperatureï¼?0.1 speedï¼?1rpm
Repetitive error â?¤±2%
Zero drift COï¼?±0.06 10-2(%)/4h CO2ï¼?±0.5 10-2(%)/4h HCï¼?±30 10-6(ppm)/4h
O2ï¼?±0.5 10-2(%)/4h NOï¼?±30 10-6(ppm)/4h
Distance drift No more than shown value error allowed (4 hours)
Indication error COï¼?±5%ï¼?absolute errorï¼?±0.03 10-2 ï¼?
CO2ï¼?±5%ï¼?absolute errorï¼?±0.5 10-2ï¼?
HCï¼?±5%ï¼?absolute errorï¼?±10 10-6 ï¼?±5%ï¼?absolute errorï¼?4001ï½?10000ppmï¼?
O2ï¼?±5%ï¼?absolute errorï¼?±0.1 10-2ï¼?
NOï¼?±4%ï¼?absolute errorï¼?±25 10-6ï¼?
environment condition oil temperatureï¼?±2ï¼?relative errorï¼? speedï¼?±1.0%ï¼?relative errorï¼?
temperatureï¼?0ï½?40 humidityï¼?â?¤80% atmospheric pressureï¼?60ï½?105KPa
Power Supplyï¼?AC 220V±10%ï¼?50Hz±1Hz(Automobile power supply inverter)
Preheating time 10min
Weight Measurement unitï¼?10Kg vice machineï¼?3Kg
Volume Measurement unitï¼?610 * 500 * 330mm
Auxiliary machine:500 * 350 * 330mm
Sampling method Exhaust gas: direct sampling, sampling tube length 5m, sampling probe length 900mm;
Temperature: the temperature measuring head into the engine lubrication oil scale hole, insert the oil rod and the length of the same length, rubber stopper blocked, to prevent oil jet and wire length: 5m;
Speed: the tachometer speed clip in high pressure flexible gasoline engine, can determine the speed of a gasoline engine.
Display mode LCD large screen liquid crystal display
major function 1)Meet GB18285-2005 national standard requirements, measurement of motor vehicle gasoline engine emissions of HC, CO, CO2, O2 and NO concentrations,Of HC, Co, CO2, the advanced NDIR regardless of light and infrared analysis technology (imported from movement detection equipment to meet the requirements of national standard OIMLR99 0 level precision, high precision, strong stability) and of O2 and no by the new electrochemical analysis technology for detection.
2)With idle speed, double idle test function;
3)Auto calculation shows that the excess air coefficient isï¼?
4)Equipped with RS-232C digital serial communication interface, convenient networkingï¼?
5)Matching speed and temperature measurement functionï¼?
In order to guarantee gas dispenser quality, our company has established an experiment center for testing and detection of overall performance of gas dispensers. This center can comprehensively simulate actual operation of gas stations and completely detect over ten functions like gas tightness, pressure protection, quantifiable gas filling, gas filling in order, segmental measurement correction for gas filling, break-away protection, solenoid valve reliability, mass flow meter accuracy, repeatability, and zero correction.
Place of origin :sichuan, china (mainland)
Brand name :hantu
Model number :jqj-c-ii
Condition: new
After-sales service provided: engineers available to service machinery overseas
Kq500 fixed gas detector is a kind of wall-mounted type detector that can be used continuously in operation environment to detect the concentration of combustion gas, oxygen, and toxic gas. The detector detects gas concentration in natural diffusion way.
Kq500 intelligent gas detector transforms the gas density in the operating site into standard electric current signal(4-20ma).
Main features:
L it can detect more kinds of gas. High precision
L fixed explosion-proof shell; it¡¯s safe and reliable
L standard 4-20ma electric current output, compatible with existing alarm control unit or dsc (distributed control system).
L imported sensor, high sensitivity, rapid response, stable and reliable
Operation is simple; easy installation and maintenance
Kq500d intelligent gas detector is a kind of wall-mounted type detector that can be used continuously in operation environment to detect the concentration of combustion gas, oxygen, and toxic gas. The detector detects gas concentration in natural diffusion way.
Kq500d intelligent gas detector transforms the gas density in the operating site into standard electric current signal(4-20ma). With led display, detector's sensor can be changed and reused as soon as it is connected to electricity.
Main features:
standard 4-20ma electric current output, compatible with existing alarm control unit or dsc (distributed control system).
led site display that is suitable for factory (optional lcd display)
L standard three buttons: so an individual can operate the detector in site.
L automatic identify and display the sensor failures, and output the corresponded current signal at the same time.
L the key operation needs to input password to prevent wrong operation.
L simple calibration function; reducing measuring error
L two levels' light alarm, relay output (connected with audible and visual alarm outside or start the exhaust system)
Gw series wireless transcription intelligent gas meter is high-tech integrative product. This series meter uses advanced wireless transmission technology. Through microelectronic control circuits, it converts the pulse signals of traditional mechanical meter into electrical signals. Then the metering data is transmitted to background platform through gprs network automatically, or it can be collected by a hand-held wireless unit from outside of the houses and after that downloaded to a computer through USB port.
GW series wireless transcription intelligent gas meter is high-tech integrative product. This series meter uses advanced wireless transmission technology. Through microelectronic control circuits, it converts the pulse signals of traditional mechanical meter into electrical signals. Then the metering data is transmitted to background platform through GPRS network automatically, or it can be collected by a hand-held wireless unit from outside of the houses and after that downloaded to a computer through USB port.
Equipped with our companys code controller, base meters are bought abroad to realize the prepaid and control functions, thus to achieve the automatic control of different functions of this new type of gas meter.
Range of application:
This product can be applied to the measurement of gas, natural gas, liquefied petroleum gas and other non-corrosive gases in the city.
Main features:
Automatic prepaid function: charging before using of it, water meter residual capacity= the original gas + newly purchased gas auto-control function: switching the gas path automatically according to the payments and gas situation.
Real time computation function: measuring on the real time and display the stock value, closing gas source automatically when the purchased gas is used up.
Power-down memory function: solid state recorder is internally installed and the data will be permanently preserved.
Status display function: displaying the amount of newly charged gas, the remaining stock and cumulative use, as well as low-voltage state etc.
Prompting function: warning when the remaining gas is used to the set value or other functions are out of work.
Overdrawing function: able to set a certain overdraft gas according to the user needs
Automatic alarm function: when the voltage is lower than certain point, alarm system will be operated and the battery must be replaced within 72 hours, otherwise, it will automatically shut down the gas resources.
Anti-gas-larceny function: shut down the gas supply automatically when there are theft of gas or illegal operations
Technical parameter:
Base meter operation criteria¦gb/t6869 q/ofd.001-2007 jjg577-2005
Current working voltage¦3.00v
Cuiescent current¦<=12va
Data hold¦>=8 years
Life span of valve¦switching frequency more than 5000 times
Accuracy degree¦level b
Four anti-function¦anti-attack, waterproof, anti-smoke, anti-knocking
Product Introduction
Chromatographic analysis technology is a kind of separation and analysis technology of multi-component mixture. It mainly makes use of the difference of boiling point polarity and absorption add coefficient of each component in the sample in the chromatographic column so that each component can be separated in the chromatographic column and detect the separated components by detection apparatus so as to conduct qualitative and quantitative analysis of multi-component mixture.
Because this method has a high separation efficiency fast analysis less sample consumption etc therefore has been widely used in petrochemical biochemical medicine and health food of the health and quarantine inspection of environmental protection industry in the medical clinical departments by gas chromatography in the field of solve the industrial production of intermediates and pollution detection of industrial products quality inspection scientific research production control and other issues.
Chromatographic instrumentIt is a kind of high cost performance multi-function economical and practical precision instrument which adopts three-column and three-gas circuit operating system. The basic type is equipped with hydrogen flame ionization detection (FID) and thermal conductivity detection deviceï¼?TCDï¼?.
Chromatographic instrumentUsing microcomputer and integrated circuit control English and Chinese interface high degree of self-motion and good reliability operating parameters keyboard setting instrument with power failure protection file storage and call function instrumentLarge screen liquid crystal displayï¼?The detection apparatus and its control assembly unit adopt plug and play control modesimplicity of operator for the instrument to conduct constant temperature and program temperature rise operation column room is equipped with flexible rear door self-motiontemperature control system the column box has excellent performance high precision temperature control quick rise and drop speed and flexible air temperature operation process Reliable easy to expand suitable for a variety of detection and sample combinations.
The detector adopts the unitized combination design which is easy to install and maintain. The chromatograph can be configured with a variety of detectors (TCD FID ECD FPD and NPD). According to the user's analysis needs the chromatograph can be configured with up to four detectors at the same time.
The chromatograph's injection system can be equipped with a variety of injection devices such as filling column head injection glass lining rapid injection and capillary column divided/undivided injection with diaphragm cleaning function.
TKQC type SF6 gas recovery device is an integrated recovery device. The device is composed of a recovery system a vacuum pumping system a cleaning system a storage system and a condensing system.
Features:
Adopt advanced principles and technology advanced design complete function reasonable structure simple operation.
Two-stage rotary vane vacuum pump the vacuum speed is fast and equiped with anti oil return device.
Automatically confirm and adjust the three phase power supply for electrical system.
Using the newest patented technology SF6 special instrument and valves more reliable than similar products.
The device adopts air cooling movable type and can be used without external water source.
Chromatographic analysis technology is a kind of separation and analysis technology of multi-component mixture. It mainly makes use of the difference of boiling point polarity and absorption add coefficient of each component in the sample in the chromatographic column so that each component can be separated in the chromatographic column and detect the separated components by detection apparatus so as to conduct qualitative and quantitative analysis of multi-component mixture.
Because this method has a high separation efficiency fast analysis less sample consumption etc therefore has been widely used in petrochemical biochemical medicine and health food of the health and quarantine inspection of environmental protection industry in the medical clinical departments by gas chromatography in the field of solve the industrial production of intermediates and pollution detection of industrial products quality inspection scientific research production control and other issues.
Chromatographic instrumentIt is a kind of high cost performance multi-function economical and practical precision instrument which adopts three-column and three-gas circuit operating system. The basic type is equipped with hydrogen flame ionization detection (FID) and thermal conductivity detection device TCD.
Chromatographic instrument using microcomputer and integrated circuit control English and Chinese interface high degree of self-motion and good reliability operating parameters keyboard setting instrument with power failure protection file storage and call function instrument large screen liquid crystal display. The detection apparatus and its control assembly unit adopt plug and play control model simplicity of operator for the instrument to conduct constant temperature and program temperature rise operation column room is equipped with flexible rear door self-motion temperature control system the column box has excellent performance high precision temperature control quick rise and drop speed and flexible air temperature operation process Reliable easy to expand suitable for a variety of detection and sample combinations.
The detector adopts the unitized combination design which is easy to install and maintain. The chromatography can be configured with a variety of detectors (TCD FID ECD FPD and NPD). According to the user's analysis needs the chromatograph can be configured with up to four detectors at the same time.
The chromatograph's injection system can be equipped with a variety of injection devices such as filling column head injection glass lining rapid injection and capillary column divided/undivided injection with diaphragm cleaning function.
BJ-92-1A-11 Combustible Gas Detector Detection of gas:
1A: natural gas
BJ-92-1A-11 Combustible Gas Detector Output:
* DC12V pulse output
* AC220V contact output
* AC220V pulse output
* AC220V Output
* Relay contact (normally open output), with the controller
BJ-92-1A-11 Combustible Gas Detector Technical Parameters
* Detection of gas: natural gas
* Detection method: FIGARO semiconductor gas sensor
* Alarm concentration: Gas explosion limit below 25%
* Power supply: AC220V 15%
* Power consumption: 3W or less
* Temperature: -10 ~ 55'C
BJ-86-3A Combustible Gas Detector Detection of gas:
Liquefied natural gas
Other
BJ-86-3A Combustible Gas Detector Technical Parameters
* Detection of gas: Liquefied natural gas
* Detection method: FIGARO semiconductor gas sensor
* Power sourceâ??: DC24V ± 15%â??
* Power consumption: 2.5W or less
* Alarm: red light, the alarm sound over 70dB
* Temperature: -10 ~ 55'C
MF5600 Series Detachable Display Gas Flow Meters General description
MF5600 series mass flow meters are specially designed for applications where the display isoften required to be placed separated away from the flow channel or meter body, such as theoxygen metering system in a hospital. These meters are opted with the standard industrialuser interfaces (RS485 and 4 ~ 20mA), and user defined alarm functions for better monitoringor control over the network. The off-the-shelf products (MF5612 and MF5619) are for gasflow measurement of 0 ~ 300 SLPM and 0 ~ 800 SLPM, respectively.
MF5600 Series Detachable Display Gas Flow Meters Features and Applications
- Detachable display that can be placed away from the flow channel via a specially designed cable
- Standard 4 ~ 20 mA or RS485 for remote data communication
- Hygienic stainless steel body ready for oxygen metering
- Extended rangeability for accurate flow monitoring and control
- Intrinsic safe enclosure