we have brand new envirude 300 hp motors in stock
Structure Size : 90 - 355 Rated Power : 0.37 / 1.66 30/37 kW Pole Number : 16 / 4-12 / 4-16 / 6-8 / 4-6 / 4-12 / 6-16 / 2-4 / 2 Protection Class : IP55 (up to 280 types), IP65 (315 types and above) (Contact us for higher protection classes.) Voltage : 380 V (Contact us for different voltages.) Frequency : 50 Hz (Contact us for different frequencies and speed control devices.) Build Type : B3 (Contact us for different structure types.) Mechanical Structure : Body and covers are cast iron, legs are ductile iron Cooling Type : IC 411 (Contact us for different cooling types and for forced cooling.) Insulation Class : F / H (Contact us for different insulation classes.) Working Regime : S1 (Contact us for S2..S10 operating regimes.) Ambient temperature : 40 C (Contact us for higher ambient temperatures.) Motor Protection : Thermistor and motor protection relay for over 250 types (Applicable to smaller types.)
Structure Size : 58-63-74-81-93 / MR65-MR71-MR-80/112 Rated Power : 1.1-7.5 kW Pole Number : 2 - 4 Protection Class : IP55 Voltage : 380 V Frequency : 50 Hz Build Type : B3 Mechanical Structure : Aluminum or Iron Body Cooling Type : IC 411 Insulation Class : F Working Regime : S1, S6- 40% Ambient temperature : 40 C Motor Protection -
Company Info. ( IATF 16949: 2016 Certified ) Subject Engine Valves Dear Sirs Were the first ( the oldest & most experienced ) Engine Valve manufacturer in Turkey. We produce Engine Valve since 1957. ( we have 60 years of experience in this field ) We can supply all your valve needs if you send us your inquiries. We produce Engine VALVES for : MAN, Mercedes Benz, Volvo, Scania, DAF, Steyr, KHD( Deutz ), MWM, Ford, Perkins, Renault, MTU, Alsthom, Volkswagen, Audi, Skoda, BMW, Fiat ( Iveco ) Lister, Dorman, Blackstone, LADA Caterpillar, Cummins, Guascor, GM, Waukesha, Wartsila, Jenbacher Nissan , Toyota, Isuzu , Mitsubishi ,Komatsu, Kia , Hyundai , JCB , Hino Foton, Faw, Fraza, Amico, Howo, etc. A short introduction film ( 338 ) showing our valve production & factory can be seen at Pls send us your inquiries for Eng. Valves, so we can submit our best offer immediately.
Truck & Bus engine parts
Engine Valve
Engine Valve
Engine Valve
Engine Valve
Engine Valve
Engine Valve
Engine Valve
Engine Valve
Engine Valve
Heavy duty truck & bus engine parts
Engine parts
We have been supplying engine, transmission, starter, alternator, transfer case, drive shaft, differential, before and after the bridge, shock absorber, brake disc, brake pump, the direction of the machine, door, poles, lamps and lanterns, rearview mirror, instrument and so on. We promises our clients : all goods from our company, can past loading test.
Surface: as your requirement Material: stainless steel aluminum brass iron zinc alloy steel carbon steel Any other material and dimension depends on customers demand. Usage: machinery furniture toy woodboard wall Manufacturing process: lath machining, cnc machining, linear cutting, stamping machining Euipment: lathe machine, cnc machine, punching machine, stamping machine Testing equipment: projector Tolerance: 0.05mm
FP 250 Engine Engine Model : 1206A- E70TTAG2 Stand By kVA: 250 Stand By kW : 200 Prime kVA: 227 Prime kW : 182 Rated Current : 327 Engine heavy duty diesel engine 12V starter and charge alternator Replaceable air, fuel and oil filters Mechanical governor control Tropical type radiator Flexible fuel hose Oil drain valve and extension hose Industrial type silencer and steel compensator Maintenance-free starter battery Water jacket heater 1500 rpm engine speed Alternat IP 21-23 Protection Standard H Insulation Class 50 Hz Frequency 4 pole brushless synchronous type alternator Automatic Voltage Regulator (AVR) 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis Convenient design for easy lifting and carrying High standard sound proof canopy design Modular design with easily removable nuts - bolts Lockable doors Transparent window for watching Control Panel Electrostatic powder painted, providing protection against harsh weather conditions Emergency STOP button Fuel tank inside the chassis Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Engine Model 1206A- E70TTAG2 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 15.08:1 Bore 105 Strok 135 Displacement Lt 7,01 Air Intake Turbocharged aftercooled Speed (RPM) 1500 Oil Capacity Lt 16,5 Standby Power kw / Hp 226 / 303 Prime Power Hp 204 / 273 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 25 Fuel Consumption (lt / h) Lt Full Load 50,6 Lt %75 LOAD 37,9 Lt %50 LOAD 25,2 Frequency Hz Power kVA 200 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 2550 Weight (Open) Kg 2120 Width (Silent) Mm 1300 Length (Silent) Mm 3900 Height (Silent) Mm 1980 Fuel Tank Capacity Lt 450 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 220 Engine: Engine Model : 1106A-70TAG4 Stand By kVA: 220 Stand By kW : 176 Prime kVA: 200 Prime kW : 160 Rated Current : 288 Engine heavy duty diesel engine 12V starter and charge alternator Replaceable air, fuel and oil filters Mechanical governor control Tropical type radiator Flexible fuel hose Oil drain valve and extension hose Industrial type silencer and steel compensator Maintenance-free starter battery Water jacket heater 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Engine Model 1106A-70TAG4 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 16:01 Bore 105 Strok 135 Displacement Lt 7,01 Air Intake Turbocharged and air charge cooled Speed (RPM) 1500 Oil Capacity Lt 18 Standby Power kw / Hp 196.3 / 265 Prime Power Hp 178.9 / 242 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 22 Fuel Consumption (lt / h) Lt Full Load 45,8 Lt %75 LOAD 34,7 Lt %50 LOAD 23,1 Frequency Hz Power kVA 200 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 DIMENSIONS Weight (Silent) Kg 2270 Weight (Open) Kg 1940 Width (Silent) Mm 1200 Length (Silent) Mm 3500 Height (Silent) Mm 1850 Fuel Tank Capacity Lt 360 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.