Ophthalmic lasik instruments & speculums (reusable titanium & disposable stainless steel): I. Lasik instruments (1). Lasik speculums, elevators & smoothers, markers & fixation rings (2). Lasik forceps (3). Lasik cannulas Ii. Speculums (adjustable & wire) Each packed in box & sterile blister or pouch packing
Feature It is a ventilation device for infant with novel structure and good performance, and chooses opening ventilation mode with high frequency and little tidle volume, so the airway pressure is low.If you want to know more. A. The tidal air can letout with constant pressure, constant current or accurately adjustable flow. B. Opening ventilation, opening intubation makes it not need casing bag, little resistance as expiration is suited for the ventilation management of infant. C. Evident effectiveness of treating ards can be shown with inserting small tube and jetting oxygen through nasal vestibule, which is secure and doesn't cause pressure wound easily. D. Peep and humidifier volume can be adjusted accurately. E. Alarm system with sound and light when no oxygen, poor of electric quantity or low airway positive pressure. F. Heated humidifier can be used for good effectiveness of humidifying. G. Accumulator jar, it can be used while being charged and can last for more than four hours. Specifications Frequency10+150 breaths/min I/e ratio1:1, 1:1.5+ 1:3 and inverse ratio Pressure atomizer rate>=6ml/h Process ventilationt=10min, Proi:f(150):f(35)=7:3 Proii:f(35):f(150)=7:3 Storage battery4ah, automatic charge when 12v Sigh:3breaths/min Alarm:alarm when battery voltage is lower than 11v, alarm lasts 6 seconds if no oxygen, alarm with audible signals and flashing light when the airway pressure is over 0.8kpa Cpap0+0.5kpa Peep0+0.20kpa Oxygen concentration adjustable:21%-90% Jetting volume rangeo+600ml/time Ventilation mode:hfjv(high frequency jet ventilation);cpap(continuous positive airway pressure);hfjv+peep(positive end-expiratory pressure), hfjv+sigh(sigh), process ventilation i and process ventilation ii. Standard packaging.
Feature It is widely used for clinical salvaging and revival also is a dedicated device used for respiration salvaging on emergency ambulance. A. An opening system is designed to avoid leakage of airway, when ventilating, the intubations may have no casing bag. Little tube may be used for ventilation when resistance of expiration is small, so that mucose won't be hurt easily. B. Airway is open during ventilation, suction and ventilation can be done synchronously, so good effectiveness of oxygen combination can be shown without inspiration and expiration synchronizing. C. Lower airway pressure is good to increase blood discharge and decrease encephal pressure. D. Suction device, its driving negative pressure is adjustable. E. Accumulator jar, it can be used continuously for not less than four hours after being charged. F. The system disposes completely with laryngoscope, inlet intubation, catheter of tracheotomy, nasal prongs tube, and air tube etc. Specifications Frequency: 10 150 breaths/min I/e ratio1:1, 1:1.51:3 and inverse ratio Sigh:6breaths/min, Cpapf1.5kpaff Suction negative pressure:-0.050mpa Driving pressure 00.15mpa Constant volume ventilation: t=10min, i/e=1:1.5 Adults:f(100):f(20)=7:3, tidal volume=550ml/time, driving pressure=0.06mpa Children:f(100):f(20)=7:3, tidal volume=350ml/time, driving pressure=0.04mpa Storage battery:4ah, automatic charge when 12v Most jetting volume:f1400ml/time Oxygen concentration adjustable:40%-90% Alarm: alarm when battery pressure is lower than 11v; alarm when the oxygen pressure is lower than 0.01mpa; alarm with sound and light when no gas Ventilation mode:hfjv(high frequency jet ventilation);cpap(continuous positive airway pressure), hfjv+sigh;constant volume ventilation. Standard packing.
Feature A. The device adopts impulse jet oxygen feeding technique with great flow rate of oxygen feeding in a shot while, when feeding oxygen, it adopts change mode major in reflux and many kinds of gas flow mechanism such as convection, laminar flow, sheet flow and so on concurrently, which is good to increase partial pressure of oxygen rapidly, at the same time fluctuation of thorax caused by increasing oxygen flow into airway is good to let out co2. B. Jet oxygen feeding is supported by pressure when inspiration and secure certain peep effect when feeding oxygen, so as to reach good effectiveness of oxygen feeding. C. Accumulator jar, it can be used while being charged and can last for four hours after having been charged. D. Alarm system with sound and light when lack of electric quantity or airway pressure. E. 300cg chooses digital display of import pressure sensor. F. 300cg has three kinds of airway limited pressure alarm for adult, child and infant. G. The device disposes pressure humidifier which has good humidigying effectiveness. Specifications Power supply:ac220v+22v 50hz+1hz I/e ratio1:1, 1:1.5+ 1:3 and 3:1 Driving pressure 0+0.15mpa Sigh:6breaths/min, i/e=1:4 Pressure regulator limit:0.30mpa Cpapnot less than 1kpa Oxygen concentration adjustable:40%-90% Process ventilationt=10min, infinite recursion Proi:f(150):f(35)=7:3 Proii:f(35):f(150)=7:3 Alarm:alarm with light and sound for no gas or no power or airway pressure is over Inner battery:4ah 12v Ventilation mode:hfjv(high frequency jet ventilation);cpap(continuous positive airway pressure), hfjv+sigh(sigh); process ventilation i and process ventilation ii, manual control mode. Standard packing
A. When the ventilation technique with open high frequency and low humidify volume is adopted, the airway pressure is low with little effect of oxygen compound is good and the oxygen partial pressure can be increased rapidly. While the one with regular frequency and great humidify volume is adopted, CO2 can be ejected easily. B. Convenient connecting, it can be connected through the nasal and endotracheal tube. C. The ventilation mode with high frequency and low humidify volume will not easily produce pressure hurt. D. The effect of oxygen dispersion is so good that the tested beastie can stand for a long time. E. Adjustable oxygen concentration, the ventilation mode with continuous oxygen stream and good humidifying effect can ensure beastie to respire independently. F. Be fit for manual ventilation test for monkey, rabbit, dog etc. G. Configured with multiform ventilation conduit for beastles or connected with gas source, in addition. Specifications·ª Frequency:8f+150 breaths/min I/E ratio·ª1:1f+1:3 and inverse ratio Driving Pressure ·ª0f+0.08MPa Gas source: High-pressure oxygen source or air compredsor. The input pressure is not more than 0.16MPa High-pressure gas source:0.16MPa Output Limit of reductor: not less than 0.16MPa Ventilation Mode:HFJV(High Frequency Jet Ventilation);CPAP(Continuous positive airway pressure),Manual Control Mode.
Tita-prosthesis piston type loop It is used for stapedioplasty surgery. It is connected between long process of incus (or malleus ù stapedioplasty) and oval window. It consists loop(flat band) and piston. Material : titanium medical gr 2 ( astm f 67 ) Shaft diameter û 0.4 mm Loop shaft diameter û 0.2 mm L (functional length) û 3.50 mm to 7.00 mm.
Ophthalmic forceps (reusable titanium & disposable stainless steel): (1). Tying forceps (2). Toothed forceps (3). Nucleus removal forceps (4). Corneal suturing double fixation forceps (5). Notched forceps (6). Corneal suturing double fixation forceps (notched) (7). Capsulorhexis forceps (8). Iol forceps (9). Prechopper forceps (10). Nucleus (bisector/trisector) vectis forceps (11). Conjunctiva forceps (12). Chalazion forceps (13). Miscellaneous forceps (14). Jewelers forceps Each packed in box & sterile blister or pouch packing.
Ophthalmic needle holders (reusable titanium & disposable stainless steel): (1). Round handle needle holders (2). Flat handle needle holders Each packed in box & sterile blister or pouch packing.
Ophthalmic scissors (reusable titanium & disposable stainless steel): (1). Conjunctiva scissors (2). Corneal scissors (3). Iris scissors (4). Stitch scissors (5). Tenotomy scissors (6). Utility scissors (7). Capsulotomy & vannas scissors Each packed in box & sterile blister or pouch packing.
Scissors/ Tc Surgical Instruments Operating Scissors Size: 13 cm
Manicure Sets
Impression Trays Dental Instruments
Gynecology - Surgical Instruments Cusco Vaginal Speculum
Both glass and PET tubes of all types, 13x75mm, 13*100mm, 16x100mm. 100pcs/rack, 1200pcs or 600pcs/ctn.
Advance technology of truecut biopsy needle perfect for cheap biopsy for renal biopsy
Fully automatic biopsy gun , Specility in Liver biopsy Renal biopsy Prostate biopsy
Semi automatic biopsy needle for renal prostate and liver biopsy
Use in radiology department
Plastic blood bag for single use is mainly composed of collecting bag, transfer bag and relevant anticoagulant. Single blood bag is used for collection, preservation and transfusion, composed of plastic blood bag with anticoagulant, collecting tube, blood-taking needle and outlet port. Multi blood bag is mainly used for collecting whole blood and for separation, preservation and transfusion, composed of collecting bag and several transfer bags. 1.Single Blood Bag S-250: 100pcs/carton G.W.:14KGS N.W.: 12kgs. 2.Single Blood Bag S-450:100pcs/carton G.W.:15KGS N.W.: 13kgs. 3. Double Blood Bag D-450: 50pcs/carton G.W.:15kgs N.W.: 13kgs.
Specification: #10-25 for CS,SS. Packing: 100pcs/box, 50boxes/carton, G.W.: 8KGS N.W.: 7KGS.