Rbcm coriolis masas consisted of a pair of bended tubes. The principle is to detect coriolis force forced a pair of tubes from inner mass flow by fluid. Rbcm coriolis mass flow meters offer direct mass flow, volume flow, density, and temperature measurement of liquids and slurries ¡ª without the need for additional equipment, manual calculations, or estimations. Features Measurement medium: liquid, gas, solid, or two phases and three phases mixed fluid No moving parts, high reliability and durability Measurement of mass flow, density, temperature and volume flow Free of dead spots Temperatures up to +350 Work pressure º(0~32) mpa main technical parameters
DIN-rail KWH energy meter is a new-style single phase two wire static active energy meter, it adopts special large scale integrated circuit and international advanced technology of digital and SMT techniques and so on. Its general goal is high reliability, higher accuracy, higher reliability, light and compact, it is carried out in every step of designing, producing, testing, aging and calibration. It's easy to realize the modern managing function. It is CE approved. Rated Voltage: 110V, 230V, 400V Rated Current: 1.5(6)a, 5(30)a, 10(40)a, 20(80)a, 10(100)a Accuracy: 1.0, 2.0 Stardand: Iec/En62053 Approval: CE.
.1 Description DEM8900-1/DEM8900-2/DEM8900-3 (short form for DEM8900) is designed by adopting the updated microprocessor and digital signal processing technology, which can be applied for monitoring the electrical system. DEM8900 can measure and analyze the real time electrical parameters, such as I,kWh,kvarh., Meanwhile, DEM8900 has functions of multi-tariff,RS485 communication ( MODBUS protocol),analog output, remote input and electrical pulse output. All our instruments fulfill all important requirements and regulations concerning electromagnetic compatibility and safety isolation (IEC61000, IEC1010 standard and EN61010 standard). The devices have been developed, manufactured, and tested in accordance with Quality Assurance System ISO 9001. 1.2 Measured parameters Note 1. DEM8900-1 measure current, active energy, active power (optional, with analog output) 2. DEM8900-2 measure current, reactive energy, reactive power (optional, with analog output) 3. DEM8900-3 measure Current, active energy, reactive energy, active/reactive power (optional, with analog output) 1.3 EMC and Safety standard IEC61000-4-2 (GB/T17626.2) IEC61000-4-8 (GB/T17626.8) IEC61000-4-4 (GB/T17626.4) IEC61010-1 (GB/T4793.1). Exterior Size:91*91*72mm 0.5KGS.
Detailed product description 1. Power meter measures voltage, current, power, power factor, kwh, kvarh 2. Rs485/ modbus 3. Power quality analysis 4. Di/do PMAC735 power meter features: 1. Suit for lv/ hv voltage system 2. Compact design with all real-time measurement 3. Consist of basic unit and optional modules 4. 10 years back-up of integrated energy data 5. Large lcd, high brightness, auto-scrolling 6. High accuracy, v or i is 0.2%, kwh is class 1 7. Ct and pt programmable 8. Pluggable terminals, easy to install 9. Panel size: 96 x 96mm 10. Password protect PMAC735 power meter basic function: Provide one rs485 communication, measures and display real-time parameters: 1. Voltage¡ªua, ub, uc, uab, ubc, uca, 2. Current¡ªia, ib, ic, in 3. Active power ¨c pa, pb, pc, p 4. Reactive power ¨cqa, qb, qc, q 5. Apparent power¡ªsa, sb, sc, s 6. Power factor¡ªpfa, pfb, pfc, pf 7. Frequency 8. Active energy¡ªkwh (4 quadrant) 9. Reactive energy¨c kvarh (4 quadrant) 10. Demand and max. Record for i, p, q, s 11. Unbalance rate for u, i 12. Max./ min. Value Pmac735 power meter di/ do modules: 1. 4 status input + 4 relay output 2. 8 status input + 2 relay output 3. 8 status input + 2 pulse output 4. Profibus communication module Pmac735 power meter optional function: 1. Up to 31st harmonic analysis, k factor, thd 2. Soe (event log) 3. One 4~20ma analog output. Pilot's packing; neutral packing; customized packing.
1.Product Profile QAM8300-1M power quality analyzer is an integrated monitoring, analyzing and controlling device that offers electrical parameter metering, harmonics metering and analysis, waveform sampling, measurement of Voltage swell, dip, interrupt, Voltage unbalanced ratio, fault record, event record, data record. QAM8300-1M can monitor and detect if the power quality fulfills IEC and EN standard. With its powerful I/O functions with exterior device, QAM8300-1M can perform harmonic control, PF adjustment, and demand monitoring functions. QAM8300-1M fulfils all the important requirements of IEC 61000-4-30 Class A standard. QAM8300-1M can work with our power quality monitoring and management software to provide energy management solutions for enterprises. With its strong networking capability, QAM8300-1M can display and record all the data records on the interactive trend chart. A data report can be formed periodically. The report can be used for fault analysis, statistics, real time monitoring purpose. QAM8300-1M fulfills IEC61000-4-30 A: 2003,IEC61000-4-15:2003,IEC61000-4-7:2002,EN50160,2004 etc standards. 2.Measurement Accuracy U, I: 0.1% U, I peak value, peak factor, flicker: 0.5% 3 phase Voltage unbalanced ratio: 0.2% 3 phase Current unbalanced ratio: 0.5% Frequency: 0 .002Hz Power factor: 0 .002 Power: 0.2% Energy: Active energy 0.2% IEC60687:1992(GB/T17883-1999) Reactive energy 0.2% IEC61268(1995) (GB/T17882-1999) Harmonics: IEC61000-4-30 class A Interharmonics: IEC 61000-4-30 class A Harmonic distortion rate: 2.5% 3.EMC and safety test EN61326-1 EN61000-4-2/3/4/5/12 IEC/EN61010-2001.
MPM8000 is a powerful multifunction power meter with modular design, which can be applied for monitoring and controlling of the electrical system. MPM8000 can measure and analyze real time data, such as U, I, P, Q, S, COS¦µ, F, kWh, kVAr, etc. MPM8000 has the following functions: RS-485 communication port, 2 energy pulse output (include active energy and reactive energy), Max/min data record, and SOE event record. MPM8000 can extend functions by choosing the external optional modules: harmonic analysis, 8 remote signals on/off mode, programmable 4 analog outputs (0~5V or 4~20mA optional), data storage, Profibus Com. protocol, Ethernet communication functions. The multi-tariff function allows the user to measure energy in any interval (the min. interval is 30min.), which can read the sum, sharp, peak, valley, flat energy data in 30 days, and measure 2nd to 63rd harmonics in statistics. All our instruments fulfill all important requirements and regulations concerning electromagnetic compatibility and safety isolation (IEC61000, IEC1010 standard and EN61010 standard). The devices have been developed, manufactured and tested in accordance with Quality Assurance System ISO 9001. EMC and safety standard IEC61000-4-2 (GB/T17626.2) IEC61000-4-8 (GB/T17626.8) IEC61000-4-4 (GB/T17626.4) IEC61010-1 (GB/T4793.1). Exterior Size:91*91*72mm. 0.5Kgs.
Profile: MPM8000 is a powerful multifunction power meter with modular design, which can be applied for monitoring and controlling of the electrical system. MPM8000 can measure and analyze real time data, such as U, I, P, Q, S,COS, F, kWh, kVAr, etc. MPM8000 has the following functions: RS-485 communication port, 2 energy pulse output (include active energy and reactive energy), Max/min data record, and SOE event record. MPM8000 can extend functions by choosing the external optional modules: harmonic analysis, 8 remote signals on/off mode, programmable 4 analog outputs (0~5V or 4~20mA optional), data storage, Profibus Com. protocol, Ethernet communication functions. The multi-tariff function allows the user to measure energy in any interval (the min. interval is 30min.), which can read the sum, sharp, peak, valley, flat energy data in 30 days, and measure 2nd to 63rd harmonics in statistics. EMC and safety standard IEC61000-4-2 (GB/T17626.2) IEC61000-4-8 (GB/T17626.8) IEC61000-4-4 (GB/T17626.4) IEC61010-1 (GB/T4793.1) Measured Scope: The meter MPM8000 can be applied in single phase, 3-Ph 3Wire, 3-Ph 4Wire system. It can be applied vastly in the field of secondary measurement in high Voltage, low Voltage system, or transmission of measured data. Measured accuracy Parameters Display Direction Accuracy Voltage 0~9999.9kV Class 0.2 scope:5%~100%V Current 0~9999.9kA Class 0.2 scope: 5%~100%A Zero sequence Current Class 0.5 Power factor -1~+1 Directional Class 1 Frequency 45~65Hz ¡À0.01Hz Active Power -9999~9999MW Directional Class 0.5 Reactive Power -9999~9999MVAr Directional Class 0.5 Apparent Power 0~9999MVA Class 0.5 Active Demand -9999~9999MW Class 1.0 Reactive Demand -9999~9999MVAr Class 1.0 Active Energy 0~9999999.99Mwh Directional Class 1.0 Reactive Energy 0~9999999.99MVArh Directional Class 2.0 Phase Angle 0.0¡ã~359.9¡ã Directional Class 2.0 Current total harmonic % 0~100% Class 2.0 Voltage total harmonic % 0~100% Class 2.0. 1unit/carton, 36 unit/big carton.
The energy monitor is used to change the energy usage habits of households and save energy & money for family, and also do something for environment protection. Features: 1) with wireles tranmitting, receiver display the current power information, the money you are spending on power. 2) history power charge you had spent for monthly and annal. Up to 2 years information can be preserved. 3) check from a single location if appliances before leaving your home. Be safe every time you leave your home. 4) an audible alarm for excessive electricity usage 5) power supply: 2pcs aa for receiver; 2pcs aaa for transmitter (not include) 6) wireless transmitting range: up to 30m in room. 7) display currencies: ú, $ & euros 8) day/week/month usage view and daily/weekly/monthly average view 9) clock/date display 10)accessories: 1 receiver, 1 transmitter with, 1 dc adaptor, 1 clip on sensor, 1 instruction manual. Carton packing Szie:51*45*31cm 20pcs/ctn 0.6kg/piece
CDY series impulse test systems can be used to generate impulse voltages simulating lightning strokes and switching surges. The stage energy is 2.5 kJ~1620kJ. Max. Charging voltage is 100~7200kV. Applications covered include testing according to IEC, ANSI/IEEE as well as other national standards. The basic system can be upgraded in various ways for special tests and for greater ease of operation. A number of additional circuits and components allow optimizing the impulse test system for tests on different kinds of high voltage test objects. The generator is due to its unique, modular, patented structure perfectly suited for transportation and easy on-site erection. Also the internal inductance is the lowest ever built. We can also provide the professional solutions and equipments for: withstanding voltage testing, c & tan-delta (power factor) testing, partial discharge (PD) testing and impulse voltage testing.
Three Phase Din -Rail KWh Meter (DTS353-M) Executive Standard: IEC62052-11 2003; IEC62053-21 2003 DIN-rail standard: "SO"43864. Function and characteristic: Single measurement accurately. Technical data: Rated current: 3*1.5(6)A 3*10(40)A 3*20(80)A 3*10(100)A Rated voltage: 3*220/380V, 3*230/400V Display mode; Counter 6+1 = 999999.9kWh Impulse contant: 800imp/kWh 1000imp/kWh Connetion mode: CT type; Direct type; Power: Less than 2W, 10VA Normal temperature: -10~45degree Ultra temperature: -20~55degree. Size: 122*100*65mm.
Current : 99t1-a sq48-a Voltage : 99t1-v sq48-v Frequency : 99t1-hz sq48-hz Power : 99t1-kw sq48-kw Power factor : 99t1-cos sq48-cos
Function Measuring Range Accuracy DC Voltage 600V +/-1.0% AC Voltage 450V +/-1.2% AC Current 20-200-400A +/-2.0% Resistance 200KOHM +/-1.0% Diode Test YES Data hold YES Buzzer YES Power Supply (AAA)1.5*2 Max. Display 1999 Dimensions 150*63*28mm Weight 160g Standard Accessories Test Leads, Manual.
Model J0408 DC Voltmeter is suitable for students to measure the voltage in a DC circuit in laboratory. Measuring Range: -1~0~3V -5~0~15V Accuracy: 2.5%f.s. Sensitivity:1mA Dimensions: 138*100*97mm
Function Measuring Range Accuracy DC Voltage 200mV-500V +/-(0.5%+2dgt) AC Voltage 200V-500V +/-(1.2%+10dgt) DC Current 200uA-10A +/-(1%+2dgt) Resistance 200-20MOHM +/-(0.8%+2dgt) Battery Test 1.5V/9V/12V +/-(2.5%+2dgt) Diode Test YES Data Hold YES Low Battery Indication YES Back Light YES Input Impedance 10MOHM LCD Size 48*16mm Power Supply 9V Battery (6F22) Max. Display 1999 Dimensions 130*73.5*35mm Product Net Weight 156g Standard Accessories Test Leads, Battery, Manual
Range:-50_1200 degree celsius Accuracy: +/-3% Low Battery Indication: YES Overload Protection: YES Power Supply: 6F22,9V Max. Display:1999 Dimensions: 105*70*20mm Standard Accessories: Test Leads, Battery, Manual, Thermocouple wire
Sensitivity: (25 cents (USD)) 60mm; (Iron pipe-tube) 120mm Operating current:
Model 5050T/1010T Resistance Meter The Model 5050T/1010T is applicable for measuring insulating resistance of electronic motor cable, voltage transformers, domestic electronic facilities etc. Model Measuring range 5050T 0~500 1010T 0~1000 Dimensions 205*120*145mm
Pressure reducing station Prs for steam, naturalgas, lpg , hydrogen
Analog panel meter Din 96, 90 degree, class:+/-1.5% 96*96mm
1.Can be operated in measurement of output power with nw, uw, mw, dB and dBm readings function 2.Optional RS232 Remote Control Interface 3.0.01dBmu precision 4.Can be used for absolute power measurement and relative measurement of link loss. 5.Compact design, portable, light weight, energy-saving 6.Battery for power supply 7.Large LCD display screen, helpful to your eyes. Weight:450g Dimensions 14.0í-7.8í-3.8cm