Negative Pressure Wound Drainage Machine Intelligence Product Model: MAX400-A1 Product Composition: Host, power cord, liquid collection bottle. The host is mainly composed of vacuum pump, control circuit, pressure sensor, CPU, control panel and display, chassis and built-in lithium battery. Application: Suitable for acute wounds, chronic diabetic wounds and wounds drainage of more exudate after surgery. Product Feature: 1. With ultra-low negative pressure design (-50mmHg to -450mmHg), which is continuously adjustable 2. With super-smart design and multiple operating mode which is more practical 3. With stable performance and long life which can operate more than 10,000 hours continuously. 4. The elaborate designed muffler system controls running noise of the device in a very low range (less than 45 dB), which does not affect the patientâ??s rest. 5. With microcomputer chip controlled, it has high accuracy and user-friendly operation interface. 6. Intelligent memory system can automatically record the parameters and modes in the last setup, free from repeatedly setting after each starting up. 7. LCD digital display makes it convenient for users to adjust and operate. 8. Multiple safe power supply solutions: a. AC and DC power supply is adopted, and the host is a full DC power supply, no danger of electric shock; b. Its build-in spare battery may still endure for four hours after a power failure, while it can last 8 hours in intermittent mode; c. A 12V 5A vehicle DC power supply can also be used to ensure the continuous treatment of patients with negative pressure drainage during transfer or going out. 9. Equipped with overflow alarm device, the unit will automatically stop in service and alarm when the dirty liquid reaches the warning line, to prevent the sewage from entering the host and to avoid secondary pollution and damage. 10. With the function of automatic gas-leak alarm, the unit will then spontaneously stop and alarm when the negative pressure value remains no change within 10 minutes after the operation. 11. Multiple safety protections: air-leak alarm, automatic overheat prevention, overflow prevention, etc. Product Property: Adjusting scope: 10mmHg; Negative pressure range: -50mmHg-450mmHg; Pressure display error: + 0.2%; Suction flow: 1.5L / min-8.0L / min; Noise: not more than 45Db; External power supply: 12V 5A DC switch power supply(medically certified), the host, DC powered, has no risk of electric shock; Operation status: continuous and intermittent Contraindication: Debridement undone or wound with the necrotic eschar; Wound with tumor tissue; Sinus connected with the organs; Wound with great vessels or organs exposed.
After circumcision surgery, appropriate postoperative care will speed healing and prevent post circumcision complications.One of the best ways is using circumcision underwear. After circumcision it is really important to keep the testes clean.With special form and tested design, circumcision underwear protects the operative part from outside and creates space for air circulation. Medison circumcision underwear is comfortable to wear and easy to clean. The circumcision underwear has the following features: Protective cover with non-toxic eva material can meet the demands of the weight and hardness perfectly. Ergonomics standard underwear design and resilient cotton pants body to provide comfortable wearing experiencing. Postoperative wound protection, promote healing; No sticking to fabrics or opening wounds To relieve the pain and no more worrying about external effect to the wound; To reduce the risk of inflammation; Air holes in sponge are made for air circulation; Openable protective cover can be more convenient for using and doctor checking. Specifications: For Child Size S:For child aged 1-4 Size M: For child aged 4-7 Size L: For child 7-11 Size XL: For child 11-14
Bioguard VLabs 4X Test is a sandwich lateral flow immunochromatographic assay, developed and manufactured by Bioguard Corporation, for rapid and qualitative detection of Ehrichia canis antibody/Lyme disease(Borrelia burgdorferi)/Anaplasma antibody/- canine heartworm (Dirofilaria immitis) antigen in dogâ??s blood. The test device has a testing window, coated by an invisible T (test) zone and C (control) zone. When sample is applied into the sample well on the device, the reagent will laterally flow on the surface of the test strip. If there is enough E. canis Ab/Lyme Ab/Anaplasma Ab/CHW Ag in the sample, a visible T band will appear. The C band should always appear after a sample is applied, indicating a valid result. By this means, the device can accurately indicate the presence of E. canis Ab/Lyme Ab/Anaplasma Ab/CHW Ag in the specimen
500units before end of May
Boaray 5000D ventilator High performance ventilator for ICU Powerful and optimal ventilation modes The DualPAP ventilation mode is able to provide the patient with biphasic horizontal pressure (high pressure phase and low pressure phase). With the suitable pressure, this perfect modes not only exercises the patient's breathing muscles, but also reduces the reliance on the ventilator. Freeflow is an advanced closed-loop control technology with square wave pattern and decelerating flow pattern. Under the square wave pattern, the patient is able to breathe spontaneously in the inspiratory phase, while under the decelerating flow pattern, the system is able to adjust the flow rate according to the patient's compliance and resistance changes. It means this advanced mode greatly reducing the use of sedatives and muscle relaxants, and has obvious effects on patients with atelectasis, ARDS, acute pulmonary edema, and asthma. Comprehensive and visible monitoring function With 15 inch color touch screen, the Boaray 5000D is able to show 4 waveforms and 2 loops simultaneously. And it can monitor more than 20 important parameters to help you know the patient status in anytime. Free breathing technology for breathing freely The free breathing technology can release excessive pressure caused by a cough or active exhalation, to ensure patient safety and make breathing more comfortable. Features · Vt range: 20-2000ml; Applicable to adult, pediatric and infant Ventilation modes: VCV, PCV, SIMV(P)+PS, SIMV(V)+PS, SPONT/CPAP, Sigh, PRVC, DualPAP, NPPV, Manual, Standby Weani CO2 and SpO2 monitoring (optional) Synchronized nebulizer and air compressor (optional) Expiratory valve could be taken off for autoclavable disinfection to avoid cross-infection Active exhalation valve with anti-condensation design World leading brands of key components of ventilator ensure high accuracy and stable performance · Advanced proportional solenoid technology realize accurate ventilation control· Multi-safety mechanism and three-priority alarm of visual and audio for different risks
Emergency treat ventilator. A few goods on hand.
Hello, we supply Yuyue YH830 Bi-Level ventilator. Brand: Yuyue YH830 Electric Current Type: 200LMIN Place of Origin: China Voltage: 100-240V universal power supply Working mode: CPAP, S, T, ST mode Breathing frequency: 5-30 times / minute Poster compensation: automatic to 2500 meters Noise level: less than 26 dB Weight: 1.3KG without humidifier Size: 58.5*32.5*21.5cm 80*45*30cm Certification: CE, TUV, SGS For more details, please contact me, thanks.
This antibody detection kit is used for the qualitative detection of new coronavirus (2019-nCoV) in human serum, plasma and whole blood samples in vitro. The antibodies to the new coronavirus include IgM and IgG. Using the antibody detection kits, the IgM / IgG antibodies can be read with the naked eye in 15 minutes and can be detected on the 7th day of the infection or on the 3rd day of the onset of the disease, which can provide a rapid detection method for patients with suspected new coronary pneumonia. A positive IgM antibody indicates a recent infection, while a positive IgG antibody indicates a longer infection or a previous infection. This kit can detect IgG and IgM antibodies at the same time, which can more effectively evaluate suspected cases. It can break through the limitations of existing detection technologies on the site and operation, it also can be used as a supplement or synergy for nucleic acid detection. Advantages: 10 min read test results. Recombinant antigen of eukaryotic cells, 95% effective. Home testing without equipment.
The Diagnostic Kit for SARS-CoV-2 IgM/IgG Antibody (Colloidal Gold) adopts the solid phase colloidal gold immunochromatographic technology for the qualitative determination of IgM/IgG antibodies against SARS-CoV-2
Product name: 75% alcohol wipes Material: Non-woven, nonwoven+75% alcohol+RO pure water Sheet Size: 15*20cm Certificate: CE Size: 15*20CM Package:50 sheets
Aedmmed Shangrila 510s
Nasal swab 5-8 min made in Korea
i have a sales contract with aeonmed for vg70 kindly note the MOQ is 400 units
Emergency and transport ICU grade electronic ventilator Features Vt range: 20-2000ml(VCV);Applicable to adult, pediatric infant(â?¥5Kg) Ventilation modes: A/C(V),A/C(P),SIMV(V)+PS,SIMV(P)+PS,SPONT,PRVC 8.4 inch LCD screen for easy observation Touch screen & Navigation knob for simple operation Simultaneous display of 3 waveforms and 2 loops Synchronized nebulizer(optional) Expiratory valve is autoclavable to avoid cross-infection Active exhalation valve with anti-condensation design World leading brands of key components of ventilator ensure high accuracy and stable performance Advanced proportional solenoid technology to realize accurate ventilation control Multi-safety mechanism and three-priority alarm of visual and audio for different risks
Vt range: 20-2000ml; Applicable to adult, pediatric and infant Ventilation modes: VCV, PCV, SIMV(P)+PS, SIMV(V)+PS, SPONT/CPAP, Sigh, PRVC, DualPAP, NPPV, Manual, Standby Weaning parameter ( RSB, P0.1, NIF) 15 inch TFT touch screen & big front view for easy observation Simultaneous display of 4 waveforms and 2 loops CO2 and SpO2 monitoring (optional) Synchronized nebulizer and air compressor (optional) Expiratory valve could be taken off for autoclavable disinfection to avoid cross-infection Active exhalation valve with anti-condensation design World leading brands of key components of ventilator ensure high accuracy and stable performance Advanced proportional solenoid technology realize accurate ventilation control Multi-safety mechanism and three-priority alarm of visual and audio for different risks
Drager Medical OxyLog Pneumatic Ventilator
Medical Ventilator (Model SH300/PA900B/SH200A/) Ventilation specification Tidal volume l:E Monitoring specification VTI, VTE , MV, MVspn Fspn, Frequency, l:E Ppeak, Pmean ,Pplat, Pmin, PEEP Ã¥·³02 Compliance, Resistance P-T, F-T, V-T, P-V loop, V-F loop 20-2500ml Ventilation mode : VCV, VCV +Sigh, PCV, PRVC, SIMV+VCV, SIMV+PCV, SIMV+PRVC ,SPONT (CPAP/PSV) , BIPAP, APRV NIV/CPAP, NIV/PCV 1:10-10:1 lnspiratorytime: 0.1-12 s Pause time Pressure trigger sensitivity Flow trigger sitivity PEEP/CPAP Psupp Pinsp Phigh Plow 02 suction Ins.Hold Exp.Hold Manual ventilation Waveform Freeze: Yes Nebulization C02(optional) ETC02(optional) Optional Air compressor Humifier Support arm 0-50% (PEEP-20 to OcmH20) 1 - 20LPM 0- 50cmH20 0- 70cmH20 5- 70cmH20 21-100% 0- 70cmH20 1 00% 02 ventilation for 2mins 15s Max 15s Max 0-60 minutes adjustable CE
We have various icu and portable ventilator model . Example: VG 70 , S1100 , S3010ï¼? V6ï¼? 510Sï¼? YH-830ï¼? SH300 and ACM812A .
Package size 1 test/kit, 10 tests/kit, 20 tests/kit, 50tests/kit and 100 tests/kit. Intended use This product is used to qualitative detection of the presence of IgG antibody to SARS-CoV-2 in Human serum, plasma and/or whole blood. The common symptoms are fever, cough, polypnea and anhelation when infected with SARS-CoV-2. In more serious cases, infection may cause pneumonia, severe acute respiratory syndrome, renal failure and even death. Coronavirus can be excreted through respiratory secretions and transmitted by air droplet. Infection may be caused by saliva, sneeze and contact. Principle A Monoclonal Mouse Anti-Human IgG conjugated to colloidal gold and embedded in the sample pad reacts with the IgG antibody to SARS CoV-2 present in whole blood, serum or plasma forming conjugate/ SARS-CoV-2 antibody complex. As the mixture is allowed to migrate along the test strip, the conjugate/ SARS-CoV-2 antibody complex is captured by recombinant SARS-CoV-2 antigen immobilized on a membrane forming a colored test line in the test region.
Format: Cassette Storage: 4-30�ºC Certificates: ISO13485 Specimen: Whole Bood,Serum / Plasma Read time: 10-15 Minutes Weight: 101g Sample rule Option 1: Offering existing samples Option 2: Customized samples based on customers' specifications Sample lead time 3-10days (depends on the style) Result: 15 Minutes Shipping mode 1.Sea shipment 2.Air shipment 3.Door to door parcel Intend to use 1.The New Coronavirus (Sars-CoV-2)Test is a rapid chromatographic immunoassay for the qualitative detection of Antibody(IgG) to coronavirus in human whole blood, serum or plasma specimens. 2.Common signs of coronavirus infection include respiratory symptoms, fever, cough, wheezing and dyspnea. In more severe cases, the infection can lead to pneumonia, severe acute respiratory syndrome, kidney failure and even death. Corona viruses can be excreted through respiratory secretions, transmitted through oral fluids, sneezing, contact, and through the air droplets spread. Positive:1. Two or three distinct lines appear. One line should always appear in the control line region (C), and another one or two apparent colored line(s) should appear in the test line region(s) (T1 and T2). 2. If a line appears on the quality control line, a line appears on the test line T1, and no sline appears on the test line T2, it indicates that IgG antibody is present in the sample and no IgM antibody is present. 3. If a line appears on the quality control line, a line appears on the test line T2, and no sline appears on the test line T1, it indicates that IgM antibody is present in the sample and no IgG antibody is present. Negative: One colored line appears in the control region (C). No Apparent colored lines appear in the test lines regions (T1 and T2). Invalid: Control line(C) fails to appear. Insufficient specimen volume or incorrect procedural technologies are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test device. If the problem persists, discontinue using the test kit immediately and contact your local distributor. Note: The red line in the test line (T) can show different shades of color. However, even a very weak line should be judged as a positive result during the specified observation period, regardless of the color of the line.