Stand-combustible Gas Detector BJ-92-1A-11 Combustible Gas Detector Detection of gas: 1A: natural gas BJ-92-1A-11 Combustible Gas Detector Output: * DC12V pulse output * AC220V contact output * AC220V pulse output * AC220V Output * Relay contact (normally open output), with the controller BJ-92-1A-11 Combustible Gas Detector Technical Parameters * Detection of gas: natural gas * Detection method: FIGARO semiconductor gas sensor * Alarm concentration: Gas explosion limit below 25% * Power supply: AC220V 15% * Power consumption: 3W or less * Temperature: -10 ~ 55'C
Point Combustible Gas Detector BJ-86-3A Combustible Gas Detector Detection of gas: Liquefied natural gas Other BJ-86-3A Combustible Gas Detector Technical Parameters * Detection of gas: Liquefied natural gas * Detection method: FIGARO semiconductor gas sensor * Power sourceâ??: DC24V ± 15%â?? * Power consumption: 2.5W or less * Alarm: red light, the alarm sound over 70dB * Temperature: -10 ~ 55'C
MF5600 Series Detachable Display Gas Flow Meters General description MF5600 series mass flow meters are specially designed for applications where the display isoften required to be placed separated away from the flow channel or meter body, such as theoxygen metering system in a hospital. These meters are opted with the standard industrialuser interfaces (RS485 and 4 ~ 20mA), and user defined alarm functions for better monitoringor control over the network. The off-the-shelf products (MF5612 and MF5619) are for gasflow measurement of 0 ~ 300 SLPM and 0 ~ 800 SLPM, respectively. MF5600 Series Detachable Display Gas Flow Meters Features and Applications - Detachable display that can be placed away from the flow channel via a specially designed cable - Standard 4 ~ 20 mA or RS485 for remote data communication - Hygienic stainless steel body ready for oxygen metering - Extended rangeability for accurate flow monitoring and control - Intrinsic safe enclosure MF5600 Series Detachable Display Gas Flow Meters Specifications * Flow Range: - MF5612: 0.3 ~ 200, 300 SLPM - MF5619: 0.8 ~ 600, 800 SLPM * Turn-down Ratio: 30:1 * Accuracy: ±(1.5+0.5 FS)% * Repeatability: ±0.5% * Max. Pressure: 1.0 MPa * Operating Tenperature: -10 ~ +55'C * Output: 4~20 mA; RS485; Pules
Stand-combustible Gas Detector BJ-62-1A Combustible Gas Detector Detection of gas: liquefied natural gas BJ-62-1A Combustible Gas Detector Output: * DC12V pulse output can be driven shut-off valve * No output BJ-62-1A Combustible Gas Detector Technical Parameters * Detection of gas: liquefied natural gas * Detection methodâ??: FIGARO semiconductor gas sensorâ?? * Alarm concentrationâ??: 25% of the lower flammable limit or lessâ?? * Power supply: AC220V ± 15% * Power consumption: 3W or less * Temperature: -10 ~ 55'C
Point Combustible Gas Detector BJ-86-3A Combustible Gas Detector Detection of gas: Liquefied natural gas Other BJ-86-3A Combustible Gas Detector Technical Parameters * Detection of gas: Liquefied natural gas * Detection method: FIGARO semiconductor gas sensor * Power sourceâ??: DC24V 15% * Power consumption: 2.5W or less * Alarm: red light, the alarm sound over 70dB * Temperature: -10 ~ 55'C
TSP-16 Series Indoor Air Quality Monitor --- Designed for hotels, houses and other public places to detect the indoor air quality * Experienced in designing IAQ product for 12 years, long term exportation to Europe and America, powerful performance guaranteed * Real-time detecting indoor PM2.5/PM10, CO2, TVOC, Temperature and relative humidity * Built-in self-owned patent measurements of temperature and humidity compensation technology * Suitable for hotels, residential projectsto analyze indoor air quality, and to control ventilation systems, etc. * Wall mounting, provide Modbus RS485 and WIFI optional * Basic function of indoor air detector TSP-16 Series IAQ Monitor Features * IAQ detector designed for civilian use with affordable price * 24 hours online real-time IAQ detector * Real-time output PM2.5/PM10, CO2, TVOC and humidity data * Using special pattern to ensure the measurement value does not effected by the surrounding * Modbus RS485 interface and WIFI available,suitable for networks in existing and modern buildings * OLED displays real-time data (optional) * Indicators with three different colors to show range of IAQ density * Wall mounting, 24VAC/VDC power supply * With over 12 years' experience in designing IAQ products and long-term exportation to Europe and America, we provide a dozen of different types of IAQ * Products for different applications * RJ45 Ethernet interface product customizable TSP-16 Series Indoor Air Quality Monitor Main Application * Smart Home Systems *Residential projects * Hotels, class rooms, offices and other public places where need IAQ monitoring with civil level *Air quality monitoring in other public places TSP-16 Series Indoor Air Quality Monitor Specifications * Detection Parameters: PM2.5/PM10, CO2, TVOC, temperature & humidity * PM2.5 Measuring Range: 0~1000μg/m3 * PM10 Measuring Range: 0~1000μg/m3 * Temperature Measuring Range: 0'C ~ 50'C * Humidity Measuring Range: 0~99%RH * CO2 Measuring Range: 400~2,000ppm * Measuring Range: 0~ 4.0mgâ??m3 * Operating Temperature: 0~50'C * Operating Humidity: 0~99%RH * Power supply: 24VAC±10%, or 12~36VDC
We are the reputed supplier and importer of hga-03 headspace gas analyzer in india - contact us now to get quick quote for hga-03 headspace gas analyzer in india by labthink
We are the reputed supplier and importer of HGA-02 Headspace Gas Analyzer in India - Contact us now to Get Quick quote for HGA-02 Headspace Gas Analyzer in India by Labthink
We are the reputed supplier and importer of classic 650 headspace gas analyzer in india - contact us now to get quick quote for classic 650 headspace gas analyzer in india by labthink.
BR-V is a real-time air quality monitoring instrument used to detect air quality of indoor environment. It use high-precision sensor and translate the pollutant concentration in the air directly into intuitive data to provide air quality monitoring information and effective protection for your family health.
Vasthi Instruments are global leaders in manufacturing of so2 analyzer,gas analyzers, gas detectors,Ozone Analyzers, online calibrator for calibration,dew point analyzer,particulate monitors,Continuous Ambient air quality monitoring system, stack gas analyzers and have been supplying instruments to customers worldwide,
Vasthi instruments are global leaders in manufacturing of so2 analyzer, gas analyzers, gas detectors, ozone analyzers, online calibrator for calibration, dew point analyzer, particulate monitors, stack gas analyzers
Vasthi model vt-90-o2, oxygen gas transmitter deficiency sensors are non-intrusive â??smart oxy meterâ?� sensors designed to detect and monitor o2 in air over the range of 0-25%.
Vasthi model vt-90-o2, oxygen gas transmitter deficiency sensors are non-intrusive â??smart oxy meterâ?� sensors designed to detect and monitor o2 in air over the range of 0-25%.
The Model SGM 1000 for H2S Monitor is an online mains operated Micro controller based system with alarm, zero facility and span for measuring concentration of H2S gas in line. Its sensor (detector) senses the gas concentration and transmits a proportionate signal to the digital monitor.
1) Over 54.000 engines well protected by VISATRON 2) Automatic opacity adaptation to engine in normal operation - False Alaram -free Sysytem even under frequent changes in engine load and rpm. 3) Extremely low maintenance cost - designed for engine lifetime. 4) Active dirt protection of optics by clean air- only available from SCHALLER AUTOMATION 5) Designed for vibration beyond classification rules. 6) Class approval of 11 Classification Societies.
Industrial gas detector devices.
Gas detectors for home, industrial and portable use.Distribution for gas detectors
Gas analyzer, engine analyzer, lux meter, opacity meter, speed radar and other automotive diagnostic equipments.After sales service
Gas meter and accessories.