Transformers,Distribution and Power Transformer,Varivolt Safety Transformers Diesel Generators Industrial Panels Stabilizers Energy Saver Industrial Panels
Warning lamp, transformer, voltage regulator, fire series.Warning lamp, transformer, voltage regulator, fire series
Medium voltage power distribution transformer.Produce
Crgo core for distribution transformer from 11kva to 5000kva..
Led lighting, led converter, led converter transformer, kitchen wired, ic chip.Manufacturing
TRANSFORMER : ALL TYPE : Dry Type/Air Cooled, Oil Cooled, Water. BRAND: SCHNEIDER ELECTRIC AND ALL OTHER BRAND AVAILABLE. we are trader of Distribution Transformer and supply all over world. We have 20 Years Experiance Technical team for Desining and Winding of Diffrent types of Transformer. We have 15 Years Experiance Technical Team for Testing of Transformers. We can supply transformer up to 33kV and up to 5000kVA.
GE TRANSFORMER PROTECTION RELAY MODEL :- MUITILIN T60-N11-AKH-F8L-H6N-M8L-P6P U6P-W6;
'ALSTOM' Protection Relay MODEL NO:- P64392AE6M0060M;
GE TRANSFORMER PROTECTION RELAY The T60 Transformer Protection System is part of the Universal Relay (UR) series of products. It is a microprocessor-based relay for protection of small, medium, and large three-phase power transformers. The relay can be configured for a maximum of six three-phase current inputs and six ground current inputs, and can satisfy applications with transformer windings connected between two breakers, such as in a ring bus or in breaker-and-a-half configurations. The T60 performs magnitude and phase shift compensation internally, eliminating requirements for external CT connections and auxiliary CTs.
ALSTOM GBCDG61EG020SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG020SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3M S/R Output contacts 2M S/R C.T.Secondary 1 amps Frequency 50 Hz Burden 3 VA Operating time 3 secs Current setting - E/F 0.1 to 0.4 amps High set - O/C Setting 4 to 16 amps High set - E/F Setting 1 to 4 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9126 901 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
GBCDG61EG031SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG031SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Contacts 3M S/R Output contacts 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 1.3 secs Current setting - E/F 1 to 4 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 10 to 40 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9125 904 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG038SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG038SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Aux.conts.with flag. 3M S/R Output contacts 2M S/R C.T.Secondary 1 amps Frequency 50 Hz Burden 3 VA Operating time 1.3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C Setting 4 to 16 amps High set - E/F Setting 2 to 8 amps High set & conts with flag CAG 13 / 2M S/R Name plate RFG9125 902 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG039SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG039SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Aux.conts.with flag. 3M S/R Output contacts 2M S/R C.T.Secondary 1 amps Frequency 50 Hz Burden 3 VA Operating time 1.3 secs Current setting - E/F 0.1 to 0.4 amps High set - O/C Setting 4 to 16 amps High set - E/F Setting 2 to 8 amps High set & conts with flag CAG 13 / 2M S/R Name plate RFG9125 901 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
Altrazeal® is a patented powder dressing specially engineered to cover and protect the wound and to provide an ideal moist wound healing environment that supports cellular function and tissue repair. Its non-resorbable, sterile granules aggregate when hydrated with saline to form a moist, flexible, oxygen permeable film that fits and seals the wound. The skin-like barrier serves many functions that promote healthy granulation tissue growth: 1. seals and protects the entire wound surface 2. allows oxygen transportation 3. manages exudate through vapor transpiration 4. prevents penetration of exogenous bacteria Altrazeal® enables extended wear time, allowing the wound to heal without disturbing the wound bed with frequent dressing changes.
Spectrolab M
Spectrolab M
Material & Structure : Bottle will be of robust construction and is made out of SS (304&316 Grade)such that no damage occurs during frequent transportation of samples from site to laboratory. Application &Advantage: Oil Sampling bottles are mandatory as per IS-9434-1992 standard to collect the oil sample only in Stainless Steel Bottle under positive pressure to ensure the proper and correct results of DGA.
It is used as an addictive of sulphur in Iron and steel smelting to improve the cutting performance. Origin - India and China For price, specification and other details please contact us.
TRANSFORMER : ALL TYPE : Dry Type/Air Cooled, Oil Cooled, Water. We can supply small transformer from 33kV and up to 54000kVA or more. For more details please contact us.
We can supply solar transformers ideally suited for large MW scale solar PV plants. Bullet Points - . Inverter duty Solar transformers, suitable for solar load profile . Multi-winding (2 to 6 windings), oil-filled or dry type. . 2MVA to 12.5MVA, LV Side: 0.35kV to 0.69kV, HV Side 3.3kV to 33kV . Low-loss, with Aluminum or Copper winding. . Electrostatic shield between LV and MV Winding. For more details please contact us.