DUMB-48/50H wall-mounted power system
Power source DZY-48 50B supporting monitoring module
Dynamic power DZY 48/50HI communication power
hydraulic power supply DZY-48/50D1
VAPEL Switching Power Supply Model GIE4805S
Vaper Epw50-27A 24V 27V Switching Power Supply
Ericsson BTS / PDU - Power Distribution Unit PDU0201
HUAWEI ETP48150 is an AC/DC embedded power system, configure 15A/30A high rectifier modules, and provides 150A rated current output.
Supply Original HUAWEI DC 48V 150A Embedded Power System ETP48150-X3N1
Huawei Etp48200 Embedded Power Unit System
Embedded Type Telecom Power System 48V DC ETP48300-C6D2
riginal HUAWEI Embedded Power System ETP48300-C9A3
Huawei ETP4830 A1 Power is a -48v embedded communication power supply system
HUAWEI ETP4890-A2 embedded DC power system
Original Huawei ETP4890, Et4890-B3a2 Embedded Power Supply System
Emerson Psc4875/25 Embedded Power Supply
NetSure 211 C46 Embedded Power Supply System
[ CHARACTERISTICS ] Accurate heat consumed under heat load is measureable * Display of various information : Heating energy / cooling energy Instantaneous heat and accumulated quantity, temperature , instantaneous flow rate, accumulated flow rate, etc. â?¢ Easy data transfer function through MODBUS RS 485 [ SPECIFICATIONS ] * Display - DC Type : Touch Screen Color Graphic LCD - AC Type : 2 X 20 Characteristic LCD with El Backlight or VFD * Temperature - Operating temperature: 0 ~ 60 â??â?? - Storage temperature: 25 ~ 70 * Power : 85 ~ 264 V AC / 12 V DC * Case dimension : (W) 150 mm X (H) 180 mm X (D) 50 mm * Input - Frequency Range: 0 Hz to 5 kHz / K factor Range: 0.0001 to 50,000.000 (Pulse / Units) - RTD Signal Type: Open Collector, Voltage or Current Pulse * Output - Analog Function: 4 ~ 20 mA calorific output / accuracy: 0.1% - Pulse Output #1 (Energy Total) Output: Open Collector transistor will sink 50 mA max - Pulse Output #2 (Flow Total) Pulse width: 5 ms , 10 ms , 100 ms , 200 ms * Communication - Kinds RS 485 MODBUS - Baud Rate 1200 ~ 19,200 BPS - ID code 4 Multi Point communication, specific address programmable * Display unit - Energy kWh, J , cal , BTU - Volume m3, L * Data logging - Logging interval : Day, hour and second can be set - Logging information : Volume Total, Volume Rate, Energy Total, Energy Rate, Temperature, Date & Time - Internal memory 12 months (Logging interval: 1 minute storage, 1 year storage) For more details on quality Korean flowmeters, please feel free to visit
[ CHARACTERISTICS ] Various inputs such as flow meters and pressure gauges. Real time communication through Modbus, BlueTooth , etc. 2G Data logging â?¢ Convert MODBUS or RS232 input to HART Item [ SPECIFICATIONS ] * Display 3.5 inch (320 x 240) Touch Screen Color Graphic LCD * Power : 90 ~ 240 V AC (Free Volt) * Output : RS 232 ASC DATA, HART Communication, RS485 MODBUS, 4~20 mA Output(24bit) of Flow Rate, MODBUS TCP/IP Ethernet(LAN), BlueTooth Wireless, 2 GB Memory, Memory Data Download USB Memory, Total Pulse Output(TTL), DC 24 V Power (0.6 A) * Input : RS 232 ASC DATA, HART Communication RS 485 MODBUS Communication 4 ~ 20 mA * Protection class : IP 65 * Piping pressure input 24 V DC pressure gauge drive and display * Size : (W) 150 mm X (H) 180 mm X (D) 50 mm
Product Features: Online measurement of AC current below 60kV (operate with insulated rod above 600V). Features 1. The unique U-shaped opening structure realizes unobstructed measurement, which is particularly convenient for on-site measurement. 2. Suitable for high current test, range: 0.00A~9999A 3. It adopts wireless transmission mode, and the transmission distance is 100m. Data retention function, data storage function.