Product Features:
Online measurement of AC current below 60kV (operate with insulated rod above 600V).
Features
1. The unique U-shaped opening structure realizes unobstructed measurement, which is particularly convenient for on-site measurement.
2. Suitable for high current test, range: 0.00A~9999A
3. It adopts wireless transmission mode, and the transmission distance is 100m.
Data retention function, data storage function.
BLUE JAY DC current panel meters with a DC signal conditioner board combine high accuracy with high read rate and a wide range of isolated output options for computer interface and control. Accuracy is 99.99% of full scale ±1 counts DC ammeter operation provides four full-scale current ranges 5.00A with 25mA resolution. The 5.000 A range measures can connect current shunt to expand the measure range.. All current and ranges are factory calibrated, without recalibrating the meter. External current shunts are fully supported. Scaling is 75 mV - 5A, more than 5A will set transformer ratio from the front panel of the meter. The scalable readout is four full digits up to 9,999 counts. Shunt is remotely located for direct sensing. This allows the current carrying wires to take a more direct path to the batteries and alleviates the need to route them through the meter case.
Digital Voltage/Current Meter Dual Input & Display (96x48mm): Measuring dual channels (isolated) Voltage 0 100mV 600V and Current 0~199.99 10A for DC AC TRMS mixable. Mathematic function available for Addition Subtraction Multiplication Division high or low selector in 2 channels input in option. 4 relay can be multi-cross programmed individual to be a Hi Lo Hi Latch Lo Latch Go energized with Start Delay Hysteresis Energized & De-energized Delay functions, or to be a remote control. Analogue multi-cross selection output and RS 485 communication port in option
Especially developed for indication and supervision of the single-phase circuit, replaces an analogical ammeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of single-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the three-phase circuit, replaces an analogical ammeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of three-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the single-phase circuit, replaces an analogical ammeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of single-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the single-phase circuit, replaces an analogical ammeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of single-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the three-phase circuit, replaces an analogical ammeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of three-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the single-phase circuit, replaces an analogical ammeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of single-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password. Specifications Current inputs (TRMS) Communication (Option) CT primary 10 000 A Link RS485 CT secondary 1 and 5 A Type 2 ... 3 wires half duplex Sampling Rate 2 per sec Protocol Modbus RTU mode Resolution 0.001 to 1, depending on the range MODBUS speed 4800/9600bauds Burden < 0.5VA, < 0.2VA in 20A Analog Outputs (Option) Auxiliary power supply Number of outputs 1 channel AC voltage DC/AC 85~265 ± 30 % Type Isolated Frequency 50 / 60 Hz Range 0 / 4 ... 20 mA or 0-5V Consumption < 10 VA Maximum current 30 mA Front panel Alarm Outputs (Option) Display Type Red LED Super Bright Display Number of relays 1 channel Maximum Display 9999 Counts Type Passive nodes Polarity Indication "-" is indicated for negative input(option) Weight Case / Housing Material Approximate 250~400g Installation Panel mounting Environment Terminal Block Thermoplastic with Tin Plated Brass Terminal Calibration 27°C ± 5°C Dielectric Strength Operation 0 to 50°C, RH < 70% 2.5 kV at 50Hz for 1 min Storage -10 to 60°C, RH < 70%
Clamp on AC current measurement up to 200 A. The CMP-200 digital clamp meter is designed for clamp measurements of AC leakage current. Clamp on AC Current CMP-200 Features high resolution (0,1 mA), three measuring ranges: 200 mA, 2 A, 200 A. display LCD 3�½ digit (max 1999), white LED backlight, sinternal diameter clamp approx. 30 mm (1,2â?³), DATA HOLD function, for holding measured values. MAX function, AUTO-OFF function, double molded casing. Available on back-order