Overview: The RT6303B Multi-function Three Phase Energy Meter Test Instrument adopts internationally advanced new-generation digital power source technology, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The Multi-function three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis, digital frequency modulation, digital amplitude modulation, digital phase-shifting, pulse width modulation and so on to bring you such important features as high reliability and good load characteristics. Its more humane and intelligent meter calibration software makes it possible for an ordinary, heavy and boring calibration to be carried out more easily and efficiently. Technical Parameters: 1. Accuracy class: 0.1/0.05 2. Reference standard energy meter: Three phase wide-measurement range standard energy meter, Accuracy class:0.1/0.05 3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range, adjustable phase by phase 4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase 5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase 6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz 7. Output waveform distortion: Both voltage and current
The AEC1112- Computerized Universal Testing Machine with a maximum load capacity of up to 10, 20, 40, 60, 80, 100 and 200 Ton with the provision of testing various samples of metals and its different alloys for the testing in tensile mode for round and flat specimens as per the national and International standard like ASTM, DIN, ISO, EU and IS standards etc. capacity of up to 10, 20, 40, 60, 80, 100 and 200 Ton.
This easy to use gauge helps you to be certain that air and moisture have been removed from the system. 1.Unique patented thermal conductivity sensor automatically compensates for temperature. 2.Replaceable , cleanable, plug-in sensor handles 450psi positive pressure. 3.Displays 8 different units of vacuum(microns, Torr, Bar, Psi, Kpa, Kg/cm2, mmHg, inHg) 4.Displays down to the equivalent of 10 microns of vacuum 5.12¡¯ coiled sensor cord stretches to 24¡¯ for easy reach, connectivity, and readable of display 6.Operating temperature range: 0¡æ to 50¡æ(32¨H to 122¨H) 7.Low battery indicator 8.Automatic shut-off after 15 minutes 9.Weight:12Oz.(340g) with battery.
Application:used for measuring thickness and corrosion of pressure vessels,chemical equipment,boilers,oil storage tanks,etc.in industries of petroleum,shipbuilding,power station,and machine manufacturing. Model: CM8825FN In built probe(s) Operating principle: magnetic induction/eddy current (F/NF) Measuring range:0-1250um/0-50mil Resolution; 0.1/1 Accuracy: í+1-3%n or í+2.5um Min. measuring area: 6mm Min. sample thickness: 0.3mm Battery indicator: low battery indicator Metric/ imperial: convertible Power supply: 4x1.5V AAA(UM-4)battery Auto power off Operating conditions:0-+45íµ(32¿H-104¿H),í_90%RH Dimensions: 126x65x27mm weight: 81g(not including battery) Optional accessories: other range 0-200um to 15000um RS-232C cable & software: 1.USB adaptor for RS-232C 2.Bluetooth interface.
It could test the surface field of permanent materials and working magnetic field of dc motor, amplifier, magnetic separator and permanent de-ironing separator. It also could be used in the measurement of remnant magnetism of mechanical processing, magnetic polarity, remnant demagnetizing field of products, to control the magnetic condition of Electroplating staffs and test the motor magnetism, leakage of electromagnetic field and ac space field. Main features 1. Small and light, easy to take, could meet all kind of on-site test requirements. 2. Power down automatically when no operation over 40 seconds.Lower voltage indicate.Super low power consumption design.It could be used more than 80 hours continuously. 3. Dc or ac peak hold 4. Dc and ac magnetic field, two range 0-200mt, 0-2000mt. 5. Dc field polarity judgement function. 6. One-click quick automatic zero adjustment. 7. Users can select the transverse and Longitudinal probes accordingly. Power 9v laminated cell inside Display 3.5 digits lcd Test range 0~~200mt, 0~~2000 mt Basic error: ~{!@~}1% Resolution Dc~{!a~}1 range: 0.00~~200.00mt, resolution: 0.01mt Dc~{!a~}10 range: 0.00~~2000.00mt, resolution: 0.01mt Ac~{!a~}1 range: 0.00~~200.00mt, resolution: 0.01mt Ac~{!a~}10 range: 0.00~~2000.00mt, resolution: 0.01mt Ac magnetic field frequency range below 400hz Temperature error -0.06%/~{!c~}c Operation environment Temperature : -10~{!c~}c~~40~{!c~}c, humidity: 35~~75% Probe interface 5 pin socket 0.5 kg . Plastic package l 150 x w 70 x h 25 mm
Manual operation to microprocessor operated testers from 0-60kV, 0-80kV, 0-90kV and 0-100kV.
SFY-60A SFY infrared moisture meter Product attributes 1.Small in size and light in weight 2.Rapid and accurate in detection 3.Easy to operate 4.Red numeral tube used in the displaying instrument 5.Widely used 6.Available to computer and printer connection Our Products SFY infrared moisture meter is a new,rapid moisture detecting instrument based on thermal gravimetric theory While sample products are weighed by infrared moisture meter,the meter is Infrared Heating Unit and Water Evaporating Channel dry the sample products rapidly.During the process,moisture meter continuously measure and display the moisture content lost by the samples.The final numerical value is fixed and showed after the dry process is over.Compared with the traditional oven heating approach,nfrared heating has the advantage of achieving the maximum heating power within the minimum time span.Samples are dried under high temperature,which quickens the detecting time generally,a sample is moisture value is detected within several minutes.It is accurate in detection and easy to operate.Its displaying part is a red numeral tube with clear displaying results.The moisture meter can respectively display enumerated date of moisture,sample is initial and terminal data,detecting time span and temperature is initial and terminal data.Furthermore,the equipment is easily available for connection with computer and printer.Hence,SFY infrared moisture meter can be applied widely in most products which requires rapid moisture detection,ncluding medicine,cereals,seeds,tobacco,chemical,tea,food,meat textile and etc as well as in laboratory and manufacturing process in fields like agriculture and forestry,paper making.plastic or rubber making,textile and etc. Product is technical target: Weighing capacity:Generally:0~60g Specifically0~100g Minimum reading:0.002g Moisture readable: 0.01% .
We are offering eut monitoring system that includes eut monitoring, analysis and data recording. These eut monitoring systems analyzes data during the test for interference or failure conditions, and records test data for retrieval after the test is complete. It is designed as a stand-alone system to communicate with the main test system using our eut monitoring and test software. The eut (equipment under test) monitoring system combines the following: Monitoring instrumentation Video and audio equipment Software to provide eut signal monitoring (analog and digital) Eut stimulation Monitoring for visual or audio interference during testing The monitoring is enabled only after the test level is established with the main test system, since the EUT Monitoring System is fully synchronized with test system. These are appreciated because all parameters captured by the EUT Monitoring System during testing ensures to accurately recreate interference or failure points to resolve compatibility issues monitored. These systems are configured specifically to cater the test needs and can be configured for specialized requirements such as audio breakthrough required by mobile radio standards and ABS/TCS testing needed in automotive test standards. Our entire range of standard as well as customized seamless interface with main test system completes the control of the EUT Monitoring System from the control room console. System Components: EUT stimulation and monitoring instruments selected to cover applicable specifications and meet your price/performance requirements Video monitoring system using shielded color cameras to visually monitor equipment under test An audio monitoring system can supply as a stand-alone solution or built into the video camera system A system controller with application software that offers power to control monitoring equipment These are used to process and store data, graphics, and results of series measurements System cabling and switching to connect the control room with the chamber Shielded room allow test engineers complete control of the EUT monitoring system from the desktop Fiber optic links for analog and digital signal monitoring. We are offering Radiated Conducted EMS that is used for EMS Testing Many electronic products. The subassemblies must meet immunity testing requirements depending on the product's target marketplace. These are designed specifically to meet the requirements of specific environmental use and internal manufacturer's requirements. It also needs an engineer to control instrumentation from a variety of vendors and perform detailed test procedures for numerous specifications. These are known for integrating test instrumentation, system controls, positioning devices, and software to perform automated, semi-automated, and manual immunity measurements in an anechoic chamber, shielded room, or test cell. The range of test specifications is carefully evaluated to develop an integrated test environment covering the basic, generic, product family and product specific standards. The entire recommendation is based on proven system installations, in-house research and development, and extensive experience with dozens of test instrument suppliers. It result in a seamless interface the test system and the test environment. We are offering a range of Radiated Conducted EMI that is designed and manufactured to use in an anechoic chamber, shielded room, OATS, or test cell to perform automated, semi-automated, and manual emissions measurements. These systems are integrated with test instrumentation, system controls, positioning devices and software. This helps to test specific products or subsystems for electromagnetic emissions according to international, R&D and manufacturer-specific standards. Designed especially to meet customerÆs requirements, these receive the exact system solution. This is offered without unnecessary components and costs associated with off-the-shelf, "one size fits all" test systems. Further, we also offer turnkey solution for our Radiated Conducted EMI, which includes system designing and installation with dozens of test instrument supplies. The turnkey EMI Test System designed by us assist to meet product testing requirements. A typical system includes: EMI test instrumentation selected to cover applicable frequencies and meet your price/performance requirements. Antennas/LISNs/Clamps selected to match both test standards and test facility capabilities. Measurement Accessories such as switching and positioning devices that simplify control and increase efficiency. An EMI Main Control Console with instruments and system controls strategically placed to provide test engineers easy access to all functions, and a comfortable, ergonomically-correct work environment. A System Controller with Application Software that offers state-of-the-art power to perform emissions tests from pre-scan to final measurements and to control multiple EMI analyzers and receivers. Proven Solutions: Our test system developments are based on the systems in Europe, North America, and Asia. Each new system incorporates the latest technologies instead of an off-the-shelf approach to design and to explicitly cover the standards. It provides accurate, repeatable measurements and minimizes demands on your limited resources. We are offering Observation System that is appreciated by the clients for conforming to various international quality standards. These are known as Specific Absorption Rate Test Systems (SRC), which include SAR Measurements, System Components, Measurement System, Probes & Measurement Accessories and Position Controller & Positioning Robot. The detail description of Specific Absorption Rate Test Systems is as follows: The SAR System: It is used to measure electromagnetic fields and calculated SAR over a customer-specified frequency range. All tests are conducted in a shielded test room. SAR Measurements: SAR testing works with the thermal effects of human exposure to RF electromagnetic fields. It corresponds to the relative amount of RF energy absorbed of a device close to the body. The test is conducted to verify that the RF energy emitted by a device is within permissible limits for public exposure as defined by test standards. The SAR Measurement System is comprised of the following subsystems: Measurement System: It is an easy to use, flexible package optimized for dosimetric evaluation of radio products. The whole package includes Data Acquisition Electronics and system control computer. Probes and Measurement Accessories: Various broadband probes and support accessories are available based on test requirements. It includes probes to measure current distribution on radio products in free space, to measure fields inside fluids simulating body tissue and to test radiated emissions from mobile radio equipment. Position Controller and Positioning Robot: The automated robot positions the probe inside the tissue-simulating liquid over a precisely defined volume. The robot is controlled by a multiprocessor positioning device. Air tieght packing with container, steel packing, wooden packing
Application: for fuel cell stack and the MEA testing and simple analysis Input channels: 8CH, signal: 0 - 5V Output channels: 4CH, signal: 0 - 5V Sample input voltage: 0 - 50V Sample input current: 0 - 100A System error: í_ 0.4% F.S. Minimum recording interval time: 0.05 s Time accuracy: í_ 0.1% Environment requirement: 0 - 40 íµ Environment humidity:
12PSB-HTD Main function: 1. Oil supply quantity and equality in every cylinder of oil injection pump 2. Oil supply point and space angle of oil injection pump 3. Check and adjust timing machine performance 4. Test and adjust dispensing pump performance 5. Test and adjust pressure compensator 6. Measure oil back quantity of dispensing pump 7. Test electromagnetic valve performance of dispensing pump 8. Test inner pressure of dispensing pump under all kinds of rotate speed 9. Test advance angle of automatic advance machine (selective) 10. Test leakproofness performance oil injection pump 11. Connect draw oil supply pipe to examine input oil pump (ve pump) 12. High precision test journey (selective) Dimension:2300x820x1800 Wood packing
The following is the feature of the meter shell: Overall dimensions:281x180x98 Installation dimensions:255 x90.5 1, Bottom case is made of ABS-V0, or ABS-PC(UL94) 2, Upper cover(front cover) is made of PC-V0 3, Lower cover and window is made of PC-V0(UL94) 4, Nameplate is made of 0.5mm Aluminium or PC-V0 or ABS-V0(UL94) 5, Terminal housing is made of bakelite 6, Terminals is made of brass for 1.5-6A,10-40A,20-80A,or on request 7, Signal terminals No. - 2pcs-6pcs are available on request 8, short or long terminal housing cover is available 9, RS232 optical port available on front cover Standard export carton package
Ultrasonic flow meter Ultrasonic flow meter has high accuracy , better reliable , high quality and low price .It widely used in measuring water , sea water , sewage and revelation examination, maintenance , papermaking , petroleum and chemical industry .It has five main types , hand-held ultrasonic flow meter , wall-mounted , portable ultrasonic flow meter , pannel-mount and flameproof flow meter .The transducers include the clamp-on , insert transducer , pipe style transducer . The advanced circuit design , the integration of the latest semiconductors , the user-friendly software interface both in english and chinese languages and small íºcsized pcd board , all these features combine to make the tr-100 series ultrasonic flow meter the best and the biggest seller on the chinese market .And it will gain more and more recognition on the international flow meter market .
Electronic single-phase power meter Reference voltage 220v Voltage reference un-1 .2 0.7ub Current specifications 5-30a Reference frequency 50hz Grading accuracy + level Starting current 0.005ib = 0.025a Voltage power lines Communication transmission distance no Environmental conditions -25f¬f+70f¬ Relative humidity -_85% Automatic relay depth Data transmission speed Center frequency Dimensions
Reference voltage 220v Voltage reference 0.7 u un .2 b -1 Current specifications 10-40a Reference frequency 50hz Grading accuracy ++ level Starting current 0.4% ib Voltage power lines 0.8w Communication transmission distance 5m Environmental conditions -25f¬f+70f¬ Relative humidity -_85% Automatic relay depth Data transmission speed Center frequency Dimensions
Motoriduttori tubolari Tube diameter 35mm, 45mm, 59mm, 92mm Lift torque from 3n.M to 300nm
1. 5 LED digitally display output by actual value or by percentage 2. AC/DC current output range: 0~100 uA ~500uA ~2mA~5mA~20mA ~50mA ~200mA ~500mA ~2A~5A~20A~30A(optional)~50A(optional) 3. AC/DC voltage output range: 0~200mV~1V~2V~5V~10V~20V~50V~100V~200V~500V~1000V 4. Three AC frequency for option: 50Hz 60 Hz 400 Hz 5. Auto protection or manual resetting function for over load 6. Over load rang is 10% for each level of voltage current 7. Clip-on transformer testing: matching with our product of standard coil measuring range AC 0~750A ( above 1000A for part of meters) DC 0~1000A error: ±0.3%
1. Design with touch panel and mask button massive information to see and simple to use 2. built-in standard energy meter for digital closed loop feedback U I F W VAR VA PF all for reference 3. Perfect over circuit over voltage. short circuit open circuit over heat over load protection 4. Three phase rated current rated voltage can be preset by users 5. Multiple choose of voltage current phase testing point 6. Capable of measuring single phase three phase active power energy meters and reactive power energy meters 7. Large memory for data storage and searching data is very convenient 8. With R232 communication interface for PC control and software upgrade
TKDL-II live cable identification instrument is used to identify A particular cable in the power cable setting migration maintenance and fault treatment to identify A cable in the cable. It has the characteristics of accurate fast simple operation and wide application. It is an indispensable testing instrument in cable construction and maintenance. The electric/uncharged cable recognition device USES single-chip microcomputer technology to encode and power the transmitting signal at the transmitting end which drives the large calibre calipers to coupling the signal to the live cable. The single chip in the receiver decodes and phase the received phase encoding signal. The target cable is identified from a large bundle of other cables based on the uniqueness of the signal phase characteristics on the target cable. It is a light compact compact lithium battery powered portable instrument. Suitable for all kinds of high and low voltage power cables. 1. Charged identification and un-charged identification function combined not only for identification and judgment of cable outage but also for the identification and judgment of live cables the operation is extremely simple very easy to use. 2. The instrument lithium battery-powered you can work continuously for 3 to 5 hours suitable for field use of passive field.
1.Description Chase friction testing machine is used to evaluate the frictional characteristics of material in braking system in accordance with the SAE J661,GB 5763-2018 and GB/T 17469-2012. Chase machine is suitable for small bench test of M1, M2, N1, O1 and O2 vehicles brake linings. This machine is widely used for product formulation R&D, Quality control and Certification etc. 2.Principle A constant pressure is applied to the sample,which will be pressed against the inner surface of the friction drum which rotates at a certain speed, so a friction force will be generated along the tangent direction of the contact surface. The friction coefficient of the tested sample can be determined by measuring the pressure and friction force. During the test, the Chase friction tester controls the temperature change at any time according to the requirements. The drum outer ring is used to assist the heating tube heating and the back suction cooling, so that the temperature change at the sample is stable and the temperature measurement accuracy is higher. 3.Features (1)Loading by Pneumatic servo with high precision control. (2)Temperature of friction drum is adjustable to adapt to different test requirements and different climatic condition. (3)Rubbing speed can be set freely between 0 and 1000 RPM. (4)The maximum load is up to 2000N. (5)This machine is controlled by PC. Speed, loads, temperature and test time can be preset by software. Test results are saved in computer. 4.Standards SAE J661, SAE J866, GB 5763-2018, GB/T 17469-2012, 5.Specifications Speed 0 to 1000 RPM Load 0 to 2000 N Temperature 0-600 (1112) Heating power 6KW Friction drum Ф277mm Power AC 380V Weight Approximate 2100kg
1. Size of concrete specimens for compression strength test Concrete cubic specimen: 150X150X150mm, 100X100X100mm, 200X200X200mm Cylindrical concrete specimen: diameter 150X300mm, diameter 100X200mm, diameter 200X400mm 2. Brief introduction of concrete compressive strength test procedure 1) Placing the concrete specimen---place the test specimen on the lower bearing block. Carefully align the axis of the specimen with the center of thrust of the spherically seated block. 2) Apply the load continuously and without shock until the specimen fails and record the maximum load carried by the concrete specimen during the test. Note the type of failure and the appearance of the concrete. 3.Relative test method GB/T 50081 standard for test method of mechanical properties on ordinary concrete ASTM C39 standard test method for compressive strength of cylindrical concrete ASTM E74 practice of calibration of force-measuring instruments for verifying the force indication of testing machine 4. Specifications for concrete compressive strength testing machine Max. capacity: 3000KN( lower or higher capacity can make to order) Grade of testing machine: grade 1 Distance between upper and lower compression platen: 320mm Stroke of piston:50mm Size of upper and lower compression platen:375X375mm Weight :about 900kg