INSTA XPLOR COVID-19 Ag is a rapid chromatographic immunoassay for the qualitative detection of antigens specific to SARS-CoV-2 in swab samples collected from a human nasopharynx.
Fast results within 15~30 mins
Easy to useSpecimen : Nasopharyngeal swab
All necessary reagents provided & no equipment needed
Usada Barak was placed as supportive theraphy for handling the asymtomatic patient of covid-19 in health-care quarantine facilities of Bali Provincial government.
Our covid-19 antigen saliva test already got Germany BFARM number, hope to cooerate with your esteemed company, and very soon we will be in PEI list, hope to cooperate with your esteemed company, and we got very good feedback from many clients, promise you high quality.
Covid Antigen Ag saliva rapid test card,
Sensitivity: 97.1%
Specificity: 99%
Agreement: 99.57%
1. Before sampling, mark relevant sample information on the label of sampling tube.
2. According to different sampling requirements, use sampling swab to sample in corresponding parts. The specific sampling methods are as follows:
a) Nasal swab: gently insert the swab head into the nasopalatine part of the nasal meatus, stay for a while, and then slowly rotate to exit. The other swab swabs the other nostril, immerses the swab head in the sampling solution, and discards the tail. (suitable for sampling with this product)
b) Pharyngeal swab: wipe bilateral pharyngeal tonsils and posterior pharyngeal wall with swab. Similarly, immerse the swab head in the sampling solution and discard the tail. (suitable for sampling with this product)
3. Quickly put the swab into the sampling tube (including virus transport fluid).
4. Break the sampling swab at the broken place and tighten the tube cover.
5. Freshly collected clinical specimens should be transported to the laboratory within 96 hours at 4 - normal temperature, and those that cannot be transported to the laboratory within 96 hours should be stored at - 70 â?? or below. The samples should be extracted as soon as possible after being sent to the laboratory. The samples that can be extracted within 24 hours can be stored at 4. If not, they should be stored at - 70 or below
SCREEN TEST COVID-19 A rapid test for the qualitative detection of IgG and IgM antibodies to 2019-nCov, Sars-CoV-2 in human Fingerstick Whole Blood specimens. For professional in vitro diagnostic use only. The Sars-CoV-2, 2019-nCOV IgG/IgM Rapid Test Cassette is a lateral flow chromatographic immunoassay for the qualitative detection of IgG and IgM antibodies to 2019-nCovâ?¦
country of origin : Italy
Quality certificates : CE Certificate
GenePro SARS-CoV-2 Test kit is developed to enable high throughput analysis and flexibility in test numbers for a single run. It allows qualitative detection of Orf-1ab gene / E gene simultaneously. Orf-1ab gene has specific sequence from SARS-CoV-2 and E gene is common sequence within coronaviruses. The validity of RT-PCR reaction is confirmed by using RNA templete (SARS-CoV-2) as positive control.
The sampling swab uses advanced jet implanted nylon fuzz technology. Compared with conventional fiber swabs, the sample is easily penetrated, diluted, and trapped in the fiber. The nylon flocking swab has outstanding sample collection and release capability, and the release rate can reach 90%, which is much higher than that of the conventional fiber swab.
Light red media formation contains antibiotics that can effectively inhibit the reproduction of bacteria and fungi.
The iNSTAXTRACT RNA Extraction kit uses mini spin column technology for isolation and purification of COVID-19 viral total RNA from swab samples in viral transport medium, cell-free fluids such as serum, plasma, body fluid, and cell culture supernatants.
SALIENT FEATURES
-Gives good results even with low viral load samples
-Fast and simple with less preparation time
-Open system compatible with any brand of commercial RT-PCR/q-PCR kit
-Intact viral RNA and high yield
Product Details:
Usage/Application Hospital
shelf life 18 months
SD BIOLINE Syphilis 3.0 test is a solid phase immunochromatographic assay for the qualitative detection of antibodies of all isotypes (IgG, IgM, IgA) against Treponema pallidum (TP).
Specimen: Serum, Plasma, Whole Blood
Sample Volume: 10MuL Serum / Plasma and 20MuL Whole blood
Recombinant TP, 15kDa, 17kDa antigens used as captures and detectors
Product Details:
Usage/Application Hospital
Results 15 min
SD BIOLINE TB Ag MPT64 Rapid is a rapid immune chromatographic identification test for the M. tuberculosis complex. M. tuberculosis has been known to secrete more than 33 different proteins. One of the predominant proteins, MPT64 was found in the culture fluid of only strains of the M. tuberculosis complex.
Rapid discrimination between the M. tuberculosis complex and MOTT bacilli
Identification of the M. tuberculosis complex in combination with culture systems
Sample: Colony, Condensation fluid(Solid cultures) or Liquid cultures
Product Details:
Usage/Application Hospital
Tests Kit Filarial antigen
Results 10 min
The BinaxNOW Filariasis is an in vitro immunodiagnostic test used to detect Wuchereria bancrofti antigen in whole blood, serum, or plasma. The test employs an antibody specific for W. bancrofti.
Accurate: Lymphatic filariasis does not always result in clinical symptoms so the most accurate way to diagnosis is using a blood test.
Simple: The BinaxNOW Filariasis card test does not require laboratory facilities.
Convenient: The test uses finger-prick blood taken at any time of the day without regard to nocturnicity of parasite. Traditionally testing was restricted to the hours of 10 pm and 2 am when the parasite appeared in the patientâ??s blood.
Flexible: The test detects filarial antigen in whole blood, serum or plasma.
Product Details:
Usage/Application Hospital
Results 15-30 min
Specimen Whole Blood Test
Storage Room Temperature
shelf life 24 months
The Alere SD BIOLINE Malaria Ag P.f/Pan test is a rapid, qualitative and differential test for the detection of histidine-rich protein II (HRP-II) antigen of Plasmodium falciparum and common Plasmodium lactate dehydrogenase (pLDH) of Plasmodium species in human whole blood.
Optimal screening test for P.falciparum and other Plasmodium species
Ordering Information
Cat No. Description Type Pack size
Product Details:
Usage/Application Hospital
Time To Result 15 Min
Method Rapid
Shelf Life 24
Temperature 1-40C
The SD BIOLINE Malaria Ag P.f/Pv test is a rapid, qualitative and differential test for the detection of histidine-rich protein II (HRP-II) antigen of Plasmodium falciparum and Plasmodium lactate dehydrogenase (pLDH) of Plasmodium vivax in human whole blood.
Specomen: Whole blood
Time to result: 15 -30 minutes
Storage: 1-40 degree C for 24 months
Performance: Sensitivity: Pf-99.7%, Pv-95.5%
Specificity: 99.5 %
Optimal screening test for Plasmodium falciparum and Plasmodium vivax
Ordering Information
Cat No. Description Type Pack size
05FK80I40 SD Malaria Device 40 Tests
3637 Diagnostic Kits Suppliers