Elevator light curtain Centre-opening type Model: SFT-620 Number of diodes: 17 Maximum beams(distance>400m): 96 beams Size: 9mm(thickness)*24.5mm(width)*2000mm(height). One cylinder tube includes: 1 pc power supply control unit /2 pcs cables /1 pc transmitter / 1 pc receiver /1 pc use manual / 1 set mounting accessories. Each set packed in a cylinder tube and 100 sets to a wooden case.
ARN-TS2D is a MEMS based single/dual axis inclinometer module that boasts a low price tag. It is most appropriate for mechanical industry, transportation, heavy vehicle, construction and survey applications. This device returns highly accurate angular data in static conditions and can be a part of lab instrumentation, platform stabilization equipment and oem alignment measuring instruments. Single axis module returns roll and dual axis returns roll and pitch information. 1. Measurement range: 60deg (Pitch), 180deg (Roll) 2. Accuracy in static conditions: 0.1 degrees 3. Size: < 78 mm x 56 mm x 36 mm 4. Weight: < 200 grams. 5. Output rate: 1 to 50 hz configurable 6. Power supply: - +8 to +12 vdc 7. Interface: RS232, RS485 serial digital.
Cylindrical inductive proximity sensor: 1, diameter form m4 to m30. Max and min lengths available. 2, cable and connector type optional, rectangle inductive proximity sensor: 1, from size 7*7mm to 210*210mm 2, steady performance due to professional ic design 3, short-circuit, reverse polarity protection 4, widely application such as limit and counter function Plastic bay and box
Plastic column inductive proximtiy sensor 1, easy to adjust due to long-rang sensing distance 2, short-circuit, reverse polarity and surge protection. 3, strong power supply: dc:10...30v, ac: 20...250v 4, ip67(iec) Plastic bay and box
V-lok neonatal nibp cuff, single tube, latex bladde
DS-100A adult finger clip spo2 sensor. It can be compatible with All nellcor types,N40,N100,N200,N290/5,N390,N3000,N6000
Humidity measuring range: 1%rh~ 99 %rh Supply voltage vs: 10 v Time constant (33 to 80 % rh, still air @ 63%) ta: 3.5 s Deviation to typical response curve (10% to 90%) rh) :+/-2 %rh
A) voltage supply: 5 vdc B) humidity measuring range: 0~100 %rh C) response time (at 63% of signal) 33%rh to 75%rh(3): 5 s D) suitable for small bulk assembly E) reliability not affected by repeated condensations F) full interchangeability. Better than +/-3%rh and +/-0.15oc G) demonstrated reliability and long term stability H) typical 1 to 3.6 volt dc output for 0 to 100% rh at 5 v dc supply I) humidity calibrated within +/- 3% rh @ 55% rh J) temperature measurement through ntc 10 kª+ +/- 1% direct output K) ratiometric to voltage supply within the specified range
GE-ohmeda Adult finger Clip Spo2 Sensor, 3m
Input voltage: 12v Work voltage: 8-18v Outpt voltage: 1-5v Response time:
Mass air flow meter 5wk9605 Suit for: bmw Oem no.: 13 62 1 432 356 Main technical parameters: Input voltage: 12v Work voltage: 8-18v Outpt voltage: 1-5v Response time:
Performance characteristics Nominal range: 10 ppm Maximum overload: 20 ppm Sensitivity range: 0.70a 0.15ª8a/ppm Zero signal @ 20 oc: < a0.2 ª8a Baseline drift :0 to 0.6 ppm equivalent (-20 oc to 50 oc) Resolution: 0.1 ppm Response time (t90): 35 sec Linearity: linear Long term output drift:
Details as follows : Rotational-speed range : 20 . 7000 rpm Permanent ambient temperature in the cable area : -40 to + 120C Permanent ambient temperature in the coil area : -40 to + 150C Winding resistance at 20 C 860 : 10 % Inductance at 1 kHz 370mH : 15 % Degree of protection : IP67 Output voltage : 0.200V
Electrical : Output: Analogue or digital Typical Linearity: 2.5% (absolute) 1.0% (independent linearity) Typical Travel: 15mm electrical* / 18mm mechanical* (*application dependent, adaptable to larger or smaller travel requirements) Nominal Index Voltage : Programmable Electrical Limit Maximum : 20 VDC Supply Voltage : 4.5 - 5.5 VDC Typical Current Draw : 12 mA (dependent on program conditions) Maximum Response Time : 600 S Durability : Typical Vibration: 200 hrs.; 3 planes; 20 - 2000 Hz; 40G RMS;-40C -160C. Typical Thermal Shock: 500 cycles, -40C and 160C; 15 sec. transition; 30 min. soak at each temperature Typical Temperature Range: -40C > 160C
Parameter specification : 1 switching capability 10 w (max) 2 switching voltage 100 vdc (max) 3 switching current 0.5 amps (max) 4 contact resistance 1 ohms max 5 dielectric : between terminals 200vdc for 1minute between body & terminal 500vdc for 1minute body & cable insulation 500vdc for 1minute 6 must operating distance 7- 14 mm with tvsc magnet tvsc-mfax-01 7 must release distance 10-25 mm with tvsc magnet tvsc-mfax-01 8 operating temperature 80 deg c max 9 surface temperature 5 deg c max @ ambient 10 ambient temperature -20 to +50 deg c x denotes for high temperature (50 deg c ) 11 IP rating ip 67. 12 sensor dimension 35x19x10 mm 13 Cable 2 core cable with shield 14 Approvals : CE & Atex.
1.Wide operating temperature range: -40 to +300íµ 2.Dielectric strength: 1, 500v ac for one second 3.Short thermal response time in water, high stability in moisture 4.Suitable for use in high-temperature and moisture environments 5.High accuracy, small dimensions, different tolerancr available , cost-effective 6.Ul approval , rohs compliant 7.Climatic category:iec60068-1 8.Resistance tolerance ú¦ía1%í½ía10% 9.Insulation resistance: í²100mª+ 10.Dissipation constant:min. 3mw/íµú¿still airú¬ 11.Thermal time constant : 8 seconds max (still air) 12.Thermal time constant : 2 seconds max (stirred liquid) 13.Moisture resistance:(40íµ 95% rh)1000 hours R valueú¦10k-5000k B valueú¦3435, 3950, 3977, 3899, , 4050, 4020 etc. Precisionú¦+/-1%--+/-10%
1.Wide operating temperature range: -20 to +300íµ 2.Dielectric strength: 1, 500v ac for one second 3.Short thermal response time in water, high stability in moisture 4.Suitable for use in high-temperature and moisture environments 5.High accuracy, small dimensions, different tolerancr available , cost-effective 6.Ul approval , rohs compliant 7.Customized specifications are welcome 8.Climatic category:iec60068-1 9.Max power:at 25íµ=50mw 10.Resistance tolerance ú¦ía1%í½ía10% 11.Insulation resistance: í²100mª+ 12.Dissipation constant:min. 3mw/íµú¿still airú¬ 13.Thermal time constant : 30 seconds max (still air) 14.Moisture resistance:(40íµ 95% rh)1000 hours
1.Wide operating temperature range: -40 to +250íµ 2.Dielectric strength: 1, 500v ac for one second 3.Short thermal response time in water, high stability in moisture 4.Suitable for use in low and high-temperature and moisture environments 5.High accuracy, different tolerancr available , cost-effective 6.Ul approval , rohs compliant 7.Customized specifications are welcome 8.Climatic category:iec60068-1 9.Resistance tolerance ú¦ía1%í½ía10% 10.Insulation resistance: í²100mª+ 11.Dissipation constant:min. 3mw/íµú¿in airú¬ 12.Thermal time constant :20seconds max ( in water ) 13.Moisture resistance:(40íµ 95% rh)1000 hours
1.Fast response , high sensitive. 2.Glass sealing, able to stand for low temperature 3.Coaxial structure makes it easy to install and can stand for high temperature R value :10k--5000k B value :3950, 3899, 4020, 4050, 4200, etc. Precisionú¦+/-1%--+/-10%.
1.Wide operating temperature range: -20 to +300íµ 2.Dielectric strength: 1, 500v ac for one second 3.Short thermal response time in water, high stability in moisture 4.Suitable for use in high-temperature and moisture environments 5.High accuracy, different tolerancr available , cost-effective 6.Ul approval , rohs compliant 7.Customized specifications are welcome 8.Climatic category:iec60068-1 9.Max power:at 25íµ=350mw 10.Resistance tolerance ú¦ía1%í½ía10% 11.Insulation resistance: í²100mª+ 12.Dissipation constant: min.3mw/íµú¿still airú¬ 13.Thermal time constant : 15 seconds max (still air) 14.Moisture resistance:(40íµ 95% rh)1000 hours