We manufacture highly efficient and accurate resin cast potential transformers. These resin cast potential transformers are used in ac circuits, for the purpose of measuring large voltages. Their main function is to reduce the supply voltage to a small value so that it can be easily measured with standard low range ac instruments of moderate size and capacity. There are many advantages of using resin cast potential transformers for range extension of ac meters. We also offer resin cast potential transformers of dual purpose metering & protection that are also commonly used.
toroidal transformer from 20va to 25KVA IN carton
24v 12v Power Toroidal Transformer (Click here for Customized Design And Interactive Design Service) Single-phase toroidal transformers, power range from 20VA to 5000VA. Designed and tested according to EN61558. Suitable for installation in electronically equipment. Designed as a safety isolating transformer with separate insulated windings and prepared for class II equipment. Short circuit and overload protected with thermal fuse on primary side. Up to 50% less weight than a similar conventional transformer. Low magnetisation currents and no-load losses. Applications: Suitable as safety isolating transformer in constructions where low weight, flexible dimensions and optimum conditions between dimensions are preferable. Technical specifications Input voltage: Customized Frequency: 50-60Hz Output voltage: Customized According to: EN61558 Test/insulating voltage: 4kV AC RMS Construction class: II In carton
++++Standard Features 1 Product Range:15kVA-10000kVA, up to 44kV 2 System voltage: max. 36 kVA 200 BIL 3 Coolers: corrugated wall or radiator 4 Oil preservation: hermetically sealed or conservator/free breathing 5 Tap changer: off-circuit or on-load 6 Cooling medium: mineral oil, Midel 7 Steel type core clamping system 8 High voltage (HV) multilayer winding 9 Low voltage (LV) foil winding or layer winding 10 Winding materials aluminium or copper 11 temperature class transformers 12 Low noise solution 13 Efficient transformers with reduced losses 14 Liquid-filled 15Used in special conditions 16Sophisticated facilities 17 Usage of wooden case 18 3D package for drawings 19 Special test like Zero Sequence Impendence test 20 Cooling: ONAN, ONAN/ONAF, KFAF, KFW ++++Service condition a) Suitable for indoor or outdoor application b)Air temperature: Maximum temperature: +40¡æ; Minimum temperature:-30¡æ c) Humidity: Monthly average humidity 95%; Daily average humidity 90% . d) Altitude above sea level: Maximum installation altitude: 2000m. e)Max wind speed:35M/s f) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc. g) No frequent violent shake 128¡¨¢73¡¨¢129cm,1020kg
Current transformer.
Instrument transformer.
Transformer up to 33 kv & 10 mva ratings Depending on customers requirement
We can provide all type of current transformer and voltage transformer for outdoor type and indoor type, zero sequence ct.
Transformer
Core: wound by high quality cold grain silicon, annealed by advanced vacuum annealing furnaces to improve electronic data, any dimension from customer are available Wire: copper and aluminum are available weld aluminum enamel wire well to save your cost 15 to 35%, based on our know-how technology Thermal protector: cutoff and switch are both available Applications: Electronic meter and apparatus Cable tv and digital network Electronic control Medical equipment New electric power supply Decorative illumination system Monitoring and control equipment Installation: horizontal (non-conventional-type base plate), sunk, side type and bridge Label info: certificate logo, basic electronic data, manufacturer's information also can be printed according to customer's request bar code is available based on customer's request Capacity: 5va to 5kva Phase: single Input voltage: ac power with voltages of various countries Output voltage: ac or customized Frequency: 50 to 60hz Power factor: 0.9 to 0.98 Efficiency: 75 to 98% Voltage regulation: 12 to 3% Output no-load loss: 0.5 to 10.0w Temperature-rise: ¡¨¹85¡ãc Insulation class: b: 130¡ãc e: 120¡ãc Testing items: no-load test (no-load current, voltage and loss) load test (load voltage, temperature-rise) inductive voltage test dc resistance test safety test
Power range:1000va-6000va Phase:single/three phase Input/output:customized Insulation class:class e, b, f, h (optional) Isolation:3.75kv(hi-pot) Operating frequency:50/60hz Approval:ul.Ce.Rohs.Cqc According to the request by our customers
Power range:1000va-6000va 4.Low noise 5.Low loss 6.Light weight 7.High reliability 8.Flexible connection 9.Good insulation 10.Small size 11.Easy mounting 12. Approval:ul/ce/rohs/cqc
Specification: 2.Low inrush current 3.Low temperature rise 4.Low noise 5.Low loss 6.Light weight 7.High reliability 8.Flexible connection 9.Good insulation 10.Small size 11.Easy mounting 12. Approval:ul/ce/rohs/cqc
3.Low temperature rise 4.Low noise 5.Low loss 6.Light weight 7.High reliability 8.Flexible connection 9.Good insulation 10.Small size 11.Easy mounting 12. Approval:ul/ce/rohs/cqc
We are one of the leading manufacturer of all types cts of any ratio. We manufacture both outdoor and indoor types. We manufacture both resin cast & oil cooled cts As per mutual discussion
With high efficiency, low inrush current and low noise characteristics which are popular in the market. We also make reactor inductor for inverter of solar power with low loss and low noise. Power range 1000va to 30kva Phase single/three phase Input/output customized Insulation class ul class b, f, h, n (optional Isolation 4kv hi-pot
With high efficiency low inrush current and low temperature rise characteristics which are popular in the market. The transformer efficiency is up to 98%. Power range:1000va to 30kva Phase: single/three phase Input/output:customized Insulation class:ul class B, F, H, N Isolation:4KV
Sikes offers a complete line of industrial control transformers, which provide stepped-down voltages to machine tool control devices. It¡¡¥s specifically designed to meet high inrush industrial applications where electromagnetic components such as relay, solenoids and magnetic motor starters are used. Technical parameters Insulation class: h Environment exists without gas, steam, chemical deposition, dust or dirt that will affect transformer¡¡¥s insulation seriously, explosive or corrosive medium is not allowed. Standard: iec726:1982 dry power transformer , gb6450-86(equivalent to iec726:1982) Standard carton or wooden case based on the custom made product.
Isolation transformer is used for low-voltage distribution system, isolate load from power, reject stray common mode and dc voltages, ground loop potentials, electromagnetic interference (emi) and radio frequency interference (rfi) from Dielectric strength: l-l, l-g 4000vac/50hz/60s. Free of arcing breakage I se is less than 65db (to be measured at the point 1 meter away from the reactor horizontally) . Protection class: ip00 or as customer required. Insulation class: h Environment exists without gas, steam, chemical deposition, dust or dirt that will affect transformer¡¡¥s insulation seriously, explosive or corrosive medium is not allowed. Standard: iec726:1982 dry power transformer , gb6450-86(equivalent to iec726:1982) Standard carton or wooden case to the custom made transformer
Common mode choke is an important component in switching power supply, frequency inverter and ups. The choking High magnetic permeability Good frequency performance, initial permeability µ 0 can be adjusted according to insertion loss in different frequency ranges, which varies from 30000~100000 Very high initial permeability, an effective suppression of emi spike noise. Huge ranges of permeability adjustment Outstanding anti out-of balance current capacity Good temperature stability Paper ctn