Impulse voltage generator is mainly used for impulse voltage test of power equipment such as lightning impulse voltage full wave lightning impulse voltage truncation wave and operating impulse voltage wave to test insulation performance.Impulse voltage generator a power supply device that imitates impulse voltages such as lightning and operating overvoltages.It is mainly used in insulation shock withstand voltage and dielectric shock breakdown and discharge tests. Scope of application: standard lightning shock lightning cut-off wave for transformers reactors mutual transformers and other high voltage electrical appliances high voltage thyristor valve SVC(HVDC) power cables all kinds of high voltage insulators bushing operation shock and all kinds of non-standard shock wave impulse voltage test required by users.Various test waveforms (standard and non-standard waveforms user-generated waveforms) can be generated by a single set of equipment.Field of application: lightning protection and lightning test for quality inspection measurement inspection and supervision organizations power equipment manufacturers railway communications aerospace and aerospace vehicles military research units universities and meteorological departments. 900kV/67.6 kJ Lightning Impulse Voltage Generator Complete Test Equipment for Transformer Reactor Cable
Three Phase AC Voltage Regulator - BRAND - VIJAYANTA, INDIA 1. Study of Three Phase AC Voltage Regulator, Model: TPACâ??408A
Warranty: 12 months Certification: ce Place of Origin: Guangdong, China Brand Name: rawsuns Model Number: Six in one integrated control system insulation grade: H grade IP Grade: IP67 rated capacity: 60kw Maximum capacity: 120kw overvoltage protection: 720V Under-voltage protection: 380V Rated Voltage: 540VDC maximum input voltage: 700VDC Application: 4.5 tons commercial vehicles, light passenger cars
Product Introduction TKJF fit for many products it has high sensitivity high S/N a large screen which has clear testing wave displaying high frequency ellipse scan (the power is less than 1VA). auxiliary zero marking system. The discharge meter has pointer/digital display and linearity /digital function. The amplifier has large dynamic range 9 kinds of frequency band combinations. TKJF is a powerful tool for developing new high voltage electric products and improving the quality of the products. It is also an efficient testing device to judge the work condition of equipments on the work field. This device is used together with model JZF-9 or JZF-10 calibrator. product features Product Characteristics Working Principle When measured piece Cx has partial discharge under testing voltage the circuit will have pulse current which get by the input unit. The pulse signal is amplified by front amplifier and the frequency band is chose by filter amplifier then been amplified to needed amplitude by the main amplifier. The pulse signal will be displayed on oscillograph screen. The pulse value is also sent to the pulse peak meter and displayed immediately. The time window unit chooses a working period of the pulse peak meter during each cycle of testing voltage and it increases the brightness of the relevant displaying area in this time. In this way it can avoid the disturbing of fixed phase. Input discharge volume to the measured piece Cx through JZF series PD external calibrator adjust the fine adjusting knob till the displayed value is equal to the discharge volume the discharge can be read directly and conveniently on the meter without counting. The testing voltmeter will have an over zero mark signal of testing voltage through the voltmeter resistance R and the zero mark pulse will be displayed on oscillograph screen. The testing voltage can be displayed on KV meter.
Product Introduction The product combines modern advanced digital variable frequency technology and microcomputer control together therefore it can realize the full automatic voltage boost step down measurement and protection as well as the manual intervention in the process of automatic voltage boost. The full electronic design ensures the small size and light weight. The big LCD screen ensures the clear and visual display and can display the output wave form. Product Characteristics VLF (Very Low Frequency) Testers are suitable for testing power cables transformers switchgear rotating machinery and other electrical apparatus. 1. Data of current voltage wave form can be directly sampled at high voltage side so the data is real and accurate. 2. Overvoltage protection: If the output exceeds the set limit of voltage the instrument will shut-down to protect itself the actuation time is less than 20ms. 3. Overcurrent protection: It is high-low voltage dual protection in the design the accurate shut-down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current the instrument will take shut-down protection the actuation time are both less than 20ms. 4. A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protect
Designed for the requirements of the equipment it is widely used in the AC withstand voltage test of the 35-220kV class string-type voltage transformer of the power system to evaluate the main transformer from the insulation strength and also to the winding of the motor and the small transformer. Induction test; can also be used as a short-time 150Hz power supply. 1 the company's Triple frequency transformer is simple to operate reliable performance 2 can well meet the needs of transformers transformers withstand voltage
Insulation Resin Impregnated Paper/ Synthetic Rated Voltage 24kV 245 kV Rated Current Up to 6300 A Standards IEC-60137:2017 Connection Draw lead/Draw rod/Stem type Housing Silicon/Hollow Composite
Rated Voltage 24kV 170 kV Rated Current Up to 4000 A Standards IEC-60137:2017/ANSI/IEEE Connection Draw lead/Draw rod/Stem type Housing Porcelain/Composite
1. 5 LED digitally display output by actual value or by percentage 2. AC/DC current output range: 0~100 uA ~500uA ~2mA~5mA~20mA ~50mA ~200mA ~500mA ~2A~5A~20A~30A(optional)~50A(optional) 3. AC/DC voltage output range: 0~200mV~1V~2V~5V~10V~20V~50V~100V~200V~500V~1000V 4. Three AC frequencies for option: 50Hz 60 Hz 400 Hz 5. Auto protection or manual resetting function for over load 6. Over load rang is 10% for each level of voltage current 7. Clip-on transformer testing: matching with our product of standard coil measuring range AC 0~750A ( above 1000A for part of meters) DC 0~1000A error: ±0.3%
1. Built-in digital multiple function standard meter with Integrated structure of meter and power source electrical parameters can be read via software 2. adopts DDS technology CPLD and RAM embedded system featured with high stability of signal source output small fineness low distortion 3. RAM system large color LCD display massive information can be seen directly through screen 4. use PWM digital power amplifier with above 90% efficiency and 300KHz carrier frequency to have advantages of low distortion little heating high efficiency 5. Perfect protection function: voltage short circuit alarm open circuit and over load alarm 6. Built-in OCXO for 50KHz high precision impulse output which can be used to calibrate energy meter clock also can test day error/hour segment error when matching with meter calibration software (optional) 7. With 485 communication interface can do various communications test for universal meters
1. Design with touch panel and mask button massive information to see and simple to use 2. built-in standard energy meter for digital closed loop feedback U I �¦ F W VAR VA PF all for reference 3. Perfect over circuit over voltage. short circuit open circuit over heat over load protection 4. Three phase rated current rated voltage can be preset by users 5. Multiple choose of voltage current phase testing point 6. Capable of measuring single phase three phase active power energy meters and reactive power energy meters 7. Large memory for data storage and searching data is very convenient 8. With R232 communication interface for PC control and software upgrade
Single Phase Variable Inductive Load - MODEL - VIJAYANTA, INDIA 1. Single Phase Variable Inductive Load, Capacity : 8 Amp, Capacity : 10, Amp
VARIOUS DC POWER SUPPLIES AS UNDER : Brand Vijayanta , India 1. Solid State Power Supply - 0 - 300 Volt at 1, Amp. Model : S 277 2. Multi-Output Power Supply - 0- 30, Volts at 2, Amps. , 0 to +/-15 Volt at 1,Amp., 4 to 6 Volts at 5, Amps. Model : LV 35 - 3 3. Multi-Output Power Supply - 0 -30, Volts at 2, Amps. , 0 to 15 Volt at 1Amp. 4 Volt to 6 Volts at 2, Amps. Model : LV 35 - 2 4. Dual Power Supply - Dual tracking or 2 independent outputs of 0 to 30 Volts at 0 to 2 Amps. 4 Digital Meters for V & A measurements of both outputs. Model : LV 30 B/2 5. Solid State Power Supply, - 0 30 Volt at 1, Amp. Model ; LV 30/1 6. Solid State Power Supply, - Output : 0- 5, Volt at 0- 10, Amp. Model : LV 05 7. E.H.T. Power Supply - Output : 0- 1500 Volts at 1, mAmp. Model : HV- 20 8. Regulated Power Supply - +/- 12, Volt and +/- 5 Volt at 500, mAmp. Model : D 12 9. 3 Phase S.C. R. Based D.C. Power supply (Rectifier type) - Note : Also available in 30A, 60A ,200A on request Model : TPRU-100 10. 1 Phase S.C. R. Based D.C. Power supply (Rectifier type) - Note : Also available in 15A, 25A ,50A Model : SPRU-100 If you still any enquiry please feel free and contact us.
Single-port Ethernet power supply equipment, which is suitable for indoor use, can work normally from 100VAC to 240VAC input voltage. The power supply and network terminal equipment are connected by over five types of cables. It has an Ethernet data port and an output port after data and power combination. This device can provide POE power supply applications in line with IEEE802.3af/at international standards for all Ethernet devices, such as routers, switches, wireless AP, network telephones, industrial network terminals, network cameras, etc. It can also provide efficient engineering in places where power supply cannot be provided remotely or where power supply by Ethernet network lines can be used to improve system reliability and simplify equipment installation.
Product Name: Energy Storage Power Supply Model No.: JL-PS300 Capacity: 11.1V / 30AH / 300Wh Cell Type: 18650 Lithium Ion Battery Material: ABS + PC Time of charging: AC input @ 6.5H; solar input @ 3 sunny days Time of shelving: 1 year ( Pls make sure 60% up power in battery before shelving ) Product Size: 290x198x144mm Weight: 5kg
Product Name: Energy Storage Power Supply Model No.: JL-PS100 Capacity: 12000mAh/10.8V 130Wh Cell Type:18650 Lithium Ion Battery Material: ABS + PC Input: DC:12.6V/2AMax (By wall socket) 12.6V-24V/2A (solar panel) Output: DC:9V-12.6V/2A, AC: 220V/50HZ (Modified sine wave), USB-A: 5V/2.0A Product Size: 204x90x160.7mm Weight: 1.5kg Flashlight/5W Mode: High Light/Soft Light Flashlight/1.5W Mode: High Light/Soft Light
VLF (Very Low Frequency) Testers are suitable for testing power cables transformers switchgear rotating machinery and other electrical apparatus. 1. Data of current voltage wave form can be directly sampled at high voltage side so the data is real and accurate. 2. Overvoltage protection: If the output exceeds the set limit of voltage the instrument will shut-down to protect itself the actuation time is less than 20ms. 3. Overcurrent protection: It is high-low voltage dual protection in the design the accurate shut-down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current the instrument will take shut-down protection the actuation time are both less than 20ms. 4. A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protect
Product Introduction Dc Hipot Test Equipment for the power supply department, for example: DC HV withstand and leakage current test in power cables, the conductance current and 1mA reference voltage of magnetic blow out arrester and zinc oxide arrester test.ZGF DC Hipot Test Equipment supplies 60kV to 400kV from 60kV to 400kV is DC high voltage power supply equipment.It has functions of switch on protection under 0 voltage,over voltage and over current protection.They are high stability and reliability. ZGF is easy to operate , small in size and light in weight. product features Product Characteristics 1 Series dc high voltage generators have small ripple coefficient stable and reliable voltage output no noise and good reliability 2 with overvoltage overcurrent zero voltage start and fault protection voltage protection value can be set display intuitive 3 voltage current using digital display and power supply has a reading easy to monitor the output status 4 with 0.75 times voltage conversion easy to test zinc oxide arrester 5 the product structure is compact small size easy to carry
product brief introduction Product Introduction The Test Transformer(ac dc hipot tester) calls the booster it is the basic test equipment used by the power station supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products electrical equipments and insulated materials testing the insulated level of products discovering the insulated objection of quizzee scaling the capacity burdened voltage. AC HV Testing Transformer Classification: There are four kinds of high voltage testing transformer according to the medium points: 1. Oil-immersed high voltage transformer test: large capacity, cheap, convenient maintenance, mainstream products. 2. Inflatable high voltage test transformer : interrupter resistance, and light weight. 3. Dry type high voltage testing transformer: light weight, light volume, can run backward, price expensive. 4. Series type high voltage testing transformer: small volume, low voltage, light weight, easy to transport and install. warning 1. Test transformer should be applied into use with control unit as for how to use control unit please see Operation Manual of Control unit. 2. Screening wire should be applied into the direct current test to avoid straying leakage. After test discharge rod is applied to release the restored electricity. 3. The end of high frequency voltage filtering capacitance should be connected with the ground wire together with crust of control unit to connect with the earth wire. 4. The whole test should follow the regulation in high frequency voltage test site should pay more attention to the safety of equipment and body.
1 Fiber Port 1 UTP Port 10/100M 1550nm Tx/1310nm Rx 20km 19 SC Interface Commercial Temperature External Power Supply 220V AC