Note ** Product Property - A precise thermometer controlling the temperature in accordance with a user's setting by detecting the precise temperature within by ±0.5 F error of measure measurement - It can be also used Temperature Controller when you put in heat pump under the main body - Product that is currently exported to American Aquarium company. - It can be used every countries handling sea water tank ** Precaution - When you use this, you have to connect a stabilizer. like earth leakage breaker - When blackout comes or installing product, you have to check set-up temperature - only for cooling, Operating time of compressor is about 3 minutes. Wait a minute please until it operates. - Main body of product should be installed at dry area - Main body of product should be avoided from water - Do not use close to magnetic field - LO on Display : Short at temperature sensor - Temperature is under 0 C - HI on Display : - Short at temperature sensor - Temperature is under 50 C Data - Length of Sensor : 4M - Usable Power : AC 220V / 60Hz , AC 110V / 50,60Hz - Range of temperature : 0C - 50C (Cooling ; 0 C - 20 C . Heating ; 14 C - 34 C) - Accuracy : Within ± 0.5C - Maximum Current Capacity : For Cooling : 20A. For Heating : 10A
Tidy arrangement by clip for fixing air hose. Biological filter system Adjust the height of pipe by use. Micro bubble generator: special generator makes oxygen solubility high and low noise. Elasticity of the sponge restoration is excellent and can use a long time. Biological filter system: proper density and hole of sponge are optimal biological environment for bacteria to glow.
? tidy arrangement by clip for fixing air hose. ? Biological filter system ? adjust the height of pipe by use. ? Micro bubble generator: special generator makes oxygen solubility high and low noise.
Note * Product Property - Machine that can lean a 10mx10m tank in 20 minutes - Portable and minimized product (under20kg) - Outstanding perrormance to clean a tank's pond, water fountain & floor * Way to Use - Adjust water level to clean under 30cm~40cm - Grab handle, move cleaner at direction of movement on floor and side of tank - Disconnect power code, dry and keep it after you finish * Precautions - You have to be care about flooding and falling of product when cleaning - Power of water supply pump should be connected into socket of main body. And power of main body should be connected into external socket. - You have to use external socket connected earth leakage breaker Data - Power : Single-Phase 220V, 110V(For domestic) - Cleaner rated output : 180Watt - Water supply pump rated output : 140L/min - Service environment : seawater and fresh water - Maximum usable water level : 30Cm - Earth leakage breaker recommended specification - Voltage : 250VAC - Current : 20A - Sensitivity Current : 15mA Certification Condition * Electricity Safety Certification Complete. * KC Certification Complete * 2015 Patent rutility model registration (Registration Number 20-2015-0003648) Complete * 2016 KC Conformity Assessment Standard Complete The price is possible to negotiate.
Note ** Product Property - Product that can adjust sea water level and salinity constantly by detecting the level of water tank - LED light ensure well display vision - Product that is currently exported to American Aquarium company. - It can be used every countries handling sea water tank ** Way to Use - Install water sensor 1,2 in the water tank. - Connect sensor and pump into main body of water level controller. - At this time, you can select maximum or minimum water level from position of sensor ** Precautions - Main body of product should be installed at dry area. - Main body of product should be avoided from water - Do not use close to magnetic field Certification Condition ** 2011 Patent utility model registration (Registration Number 20-0454001) Complete ** Power - 220V A.C, 60Hz , 110V A.C. 50,60Hz
Aquariums stuffs.Packaging & Shipping
Cordless hair straightener, portable battery packs, mini-aquarium.
Water level controller for aquarium, thermometer for aquarium, water tank cleaner, motor error alarm.
Russia and non russia oil and gas (kazakhstan, qatar, netherlands) oil and gas products such as en590 10ppm, d6, jet fuel a1 & 54, lng, lco, ago, d2, espo, pet coke, sulphur, urea 46 granular/prilled and others. in addtion, nitrile gloves, face mask, covid testing kits, and other ppe products to overseas including the usa & europe & other countries..
Portable wireless oct devices, wireless oct devices, device for ophthalmology, device for dermatology, korean made portable oct scanner.
Affordable Kaon Series Ubiquitous OCT Scanner for Ophthalmology This optical coherence tomography (OCT) scanner is compact, slit lamp base mountable, and quite versatile. Product Specifications: - Center wavelength: 840 nm - Imaging depth: 2.6 mm (in air) - Depth resolution: 9m (in air) - Lateral resolution: ~20m - Scan range: ~9 mm x 9 mm - Power Supply: USB-A and/or Power Adaptor - A-scan rate: 26,000 per second (typical) - Output power: 750W - Dimension: 200 mm(W), 80 mm(D), 150 mm(H) - Pixel resolution: Line (512, 1024), Volume (512 x 128) - Interface: USB 3.0 to external PC
Affordable Kaon Series Ubiquitous OCT Scanner for Ophthalmology This optical coherence tomography (OCT) scanner is compact, slit lamp base mountable, and quite versatile. Product Specifications: - Center wavelength: 840 nm - Imaging depth: 2.6 mm (in air) - Depth resolution: 9m (in air) - Lateral resolution: ~20m - Scan range: ~9 mm x 9 mm - Power Supply: USB-A and/or Power Adaptor - A-scan rate: 26,000 per second (typical) - Output power: 750W - Dimension: 200 mm(W), 80 mm(D), 150 mm(H) - Pixel resolution: Line (512, 1024), Volume (512 x 128) - Interface: USB 3.0 to external PC
Kaon Series Ubiquitous OCT Scanner for Industrial Inspection OCT Testbed with built-in PC for sample analysis. Product Specifications: - Center wavelength: 840 nm - Output power: > 1 mW (high power available upon request) - Imaging depth: 2.6 mm (in air) - Depth resolution: 9 m (in air) - Lateral resolution: < 15 m - A-scan rate: 26,000 per second (typical) - Scan Pattern: Cross, Volume, Raster, Circle (Customization available) - Pixel Resolution: 1024 x 256, 512 x 128 (typical) - Scan Range: 6 mm x 6 mm (changeable by built-in PC) Product Interface & Dimensions: - Data interface: HDMI (monitor not included) - Power Supply: DC Adaptor (included) - Dimension: 240 mm(W) X 100 mm(D) X 260 mm(H) (approx.) - Weight: less than 1 kg
Kaon Series Ubiquitous OCT Scanner for Industrial Inspection OCT Testbed with built-in PC for sample analysis. Product Specifications: - Center wavelength: 840 nm - Output power: > 1 mW (high power available upon request) - Imaging depth: 2.6 mm (in air) - Depth resolution: 9 m (in air) - Lateral resolution: < 15 m - A-scan rate: 26,000 per second (typical) - Scan Pattern: Cross, Volume, Raster, Circle (Customization available) - Pixel Resolution: 1024 x 256, 512 x 128 (typical) - Scan Range: 6 mm x 6 mm (changeable by built-in PC) Product Interface & Dimensions: - Data interface: HDMI (monitor not included) - Power Supply: DC Adaptor (included) - Dimension: 240 mm(W) X 100 mm(D) X 260 mm(H) (approx.) - Weight: less than 1 kg
Handheld Kaon Series Ubiquitous OCT Scanner for Ophthalmology This OCT scanner is optimal for patients in supine position as well as animals Product Specification: - Center wavelength: 840 nm - Imaging depth: 2.6 mm (in air) - Depth resolution: 9 micrometers (in air) - Lateral resolution: ~20 microwatts - Battery Details: Charging time:
Handheld Kaon Series Ubiquitous OCT Scanner for Ophthalmology This OCT scanner is optimal for patients in supine position as well as animals Product Specification: - Center wavelength: 840 nm - Imaging depth: 2.6 mm (in air) - Depth resolution: 9 micrometers (in air) - Lateral resolution: ~20 microwatts - Battery Details: Charging time:
Affordable Kaon Series Ubiquitous OCT Scanner for Ophthalmology This optical coherence tomography (OCT) scanner is compact, slit lamp base mountable, and quite versatile. Product Specifications: - Center wavelength: 840 nm - Imaging depth: 2.6 mm (in air) - Depth resolution: 9m (in air) - Lateral resolution: ~20m - Scan range: ~9 mm x 9 mm - Power Supply: USB-A and/or Power Adaptor - A-scan rate: 26,000 per second (typical) - Output power: 750W - Dimension: 200 mm(W), 80 mm(D), 150 mm(H) - Pixel resolution: Line (512, 1024), Volume (512 x 128) - Interface: USB 3.0 to external PC
Handheld Kaon Series Ubiquitous OCT Scanner for Ophthalmology This OCT scanner is optimal for patients in supine position as well as animals Product Specification: - Center wavelength: 840 nm - Imaging depth: 2.6 mm (in air) - Depth resolution: 9 micrometers (in air) - Lateral resolution: ~20 microwatts - Battery Details: Charging time:
Used mobile phone, used laptop, note book, ipad, pad, consumer electronics, speaker, headset. used cell phone.International trade, wholesale, direct factory connecting, forwarding