FUJI developed the first infrared gas analyzer in Japan to use mass-flow sensors. Since then, we have supplied customers with various types of gas analyzers to support environmental preservation and control efforts. These efforts include measurements of atmospheric pollution and detection of low density of SOx and NOx, generated by incinerating facilities and boilers. FUJI's gas analyzers are widely used to monitor the atmosphere to help maintain a cleaner natural environment.
Sng And Lpg Gas Systems Lead Ingot..
Features and Benefits: Ø Low profile aluminum body-light weight, easier to handle, provides an attractive, image enhancing appearance. Ø Full hand insulator-protects both nozzle and vehicle, and insulates user's hands. Ø Hold-open rack is available for full service application-the one hand control means easy setting to flow rate for customer convenience. Ø Easily replaced spout-simply remove the spout retaining screw. Replacement provides and entirely new outlet check valve. Kits are available from TDW. Ø Suitable for diesel, kerosene, gasoline and gasoline with ethanol blends. Ø 100% Factory Tested. Material Body Aluminum Lever and lever guard Duratuff Main stem Extra hard stainless steel Seals Buna-N, Viton Technical Specifical Working Pressure 0.2 Mpa Auto Shut-off sensibility 0.1 second Thread NPT/BSPT Spout Outlet Diameter 15/16", 13/16" Inlet Size 3/4" Flow Rate 18-60 L/m(15/16"), 15-40 L/m(13/16") Net Weight 1.15 KG Color Options Red, Green, Blue, Yellow, Orange, Black Order Specifications Item No. Inlet Thread Spout O.D. TDW-11A01 3/4" NPT 13/16" TDW-11A02 3/4" NPT 15/16" TDW-11A03 3/4" NPT 13/16" TDW-11A04 3/4" NPT 15/16" Each Fuel Nozzle with Plastic Bag, Then with Box
Nternational quality system certification. Spec. Open length: 100mm-600mm 600mm-1200mm 1200mm-3000mm Pressure: 30n-500n 500-1000n 1000n-4000n Dia: 12/4 15/6 18/8 22/10 25/12 28/14 28/16 40/20 2)fast delivery time. 38cm*14cm*27cm Can be customized
Auto exhaust analyser Used as a pollution under control machine for petrol and diesel vehicles
1) Introduction: Gasboardâ??5020 can be used for measurement of the concentration of automobile emission gas CO ,CO2 ,HC ,O2 and NO (optional), based on NDIR technology. This analyzer is designed with portable and smaller physical dimensions. The general application is for automobile emission check station or car repair garage. 3) Features: .Proprietary Infrared(NDIR) gas sensor .Can measure gas concentration of CO ,HC ,CO2 ,O2 ,NO (optional) simultaneously .With 320*240 LCD real time display .Air/fuel ratio calculation and display automatically. .Auto-zero calibration with air .Oil temperature and RPM interface. .Plug in Printer optional. .RS-232 interface and optional software.
Auto parts cylinder heads.
Car gas conversion kits.
Auto oil pressure sensor, auto voltage regulator.
LPG auto gas systems.
Hid kit.
Oxygen gas plant, nitrogen gas plant, industrial gas plant, acetylene plant & industrial gas plant machineries and spares.
Refrigerant gas.
Unleaded Automotive Gasoline..
Diesel vehicle exhaust gas analyzer (can also be used in gasoline vehicle), belong to customized products, non standard. Increase the reverse blowing system and filtering, purifying device. Can be used for the detection and analysis of diesel oil as fuel of vehicle exhaust emissions group points. ã??Main technical parametersã?? exhaust gas analyzer measuring range COï¼?0ï½?10.0 10-2(%) CO2ï¼?0ï½?20.0 10-2(%) HCï¼?0ï½?9999 10-6(ppm) O2ï¼?0ï½?25.0 10-2(%) NOï¼?0ï½?5000 10-6(ppm) oil temperatureï¼?18ï½?150 speedï¼?100ï½?20000rpm resolving power COï¼?0.01% CO2ï¼?0.1% HCï¼?1ppmO2ï¼?0.01% NOï¼?1ppm oil temperatureï¼?0.1 speedï¼?1rpm Repetitive error â?¤±2% Zero drift COï¼?±0.06 10-2(%)/4h CO2ï¼?±0.5 10-2(%)/4h HCï¼?±30 10-6(ppm)/4h O2ï¼?±0.5 10-2(%)/4h NOï¼?±30 10-6(ppm)/4h Distance drift No more than shown value error allowed (4 hours) Indication error COï¼?±5%ï¼?absolute errorï¼?±0.03 10-2 ï¼? CO2ï¼?±5%ï¼?absolute errorï¼?±0.5 10-2ï¼? HCï¼?±5%ï¼?absolute errorï¼?±10 10-6 ï¼?±5%ï¼?absolute errorï¼?4001ï½?10000ppmï¼? O2ï¼?±5%ï¼?absolute errorï¼?±0.1 10-2ï¼? NOï¼?±4%ï¼?absolute errorï¼?±25 10-6ï¼? environment condition oil temperatureï¼?±2ï¼?relative errorï¼? speedï¼?±1.0%ï¼?relative errorï¼? temperatureï¼?0ï½?40 humidityï¼?â?¤80% atmospheric pressureï¼?60ï½?105KPa Power Supplyï¼?AC 220V±10%ï¼?50Hz±1Hz(Automobile power supply inverter) Preheating time 10min Weight Measurement unitï¼?10Kg vice machineï¼?3Kg Volume Measurement unitï¼?610 * 500 * 330mm Auxiliary machine:500 * 350 * 330mm Sampling method Exhaust gas: direct sampling, sampling tube length 5m, sampling probe length 900mm; Temperature: the temperature measuring head into the engine lubrication oil scale hole, insert the oil rod and the length of the same length, rubber stopper blocked, to prevent oil jet and wire length: 5m; Speed: the tachometer speed clip in high pressure flexible gasoline engine, can determine the speed of a gasoline engine. Display mode LCD large screen liquid crystal display major function 1)Meet GB18285-2005 national standard requirements, measurement of motor vehicle gasoline engine emissions of HC, CO, CO2, O2 and NO concentrations,Of HC, Co, CO2, the advanced NDIR regardless of light and infrared analysis technology (imported from movement detection equipment to meet the requirements of national standard OIMLR99 0 level precision, high precision, strong stability) and of O2 and no by the new electrochemical analysis technology for detection. 2)With idle speed, double idle test function; 3)Auto calculation shows that the excess air coefficient isï¼? 4)Equipped with RS-232C digital serial communication interface, convenient networkingï¼? 5)Matching speed and temperature measurement functionï¼?
In order to guarantee gas dispenser quality, our company has established an experiment center for testing and detection of overall performance of gas dispensers. This center can comprehensively simulate actual operation of gas stations and completely detect over ten functions like gas tightness, pressure protection, quantifiable gas filling, gas filling in order, segmental measurement correction for gas filling, break-away protection, solenoid valve reliability, mass flow meter accuracy, repeatability, and zero correction. Place of origin :sichuan, china (mainland) Brand name :hantu Model number :jqj-c-ii Condition: new After-sales service provided: engineers available to service machinery overseas
Orotech¡¯s product is very durable in h/w, moreover outstanding accuracy and stability in the measurement, And also nox measurement upgradable and temporary pause to measurement(hold function) too. Size : 0.40 x0.53 x 0.35 Weight : 12.0 kg/box Dimensions : 0.074 cbm/box
Kq500 fixed gas detector is a kind of wall-mounted type detector that can be used continuously in operation environment to detect the concentration of combustion gas, oxygen, and toxic gas. The detector detects gas concentration in natural diffusion way. Kq500 intelligent gas detector transforms the gas density in the operating site into standard electric current signal(4-20ma). Main features: L it can detect more kinds of gas. High precision L fixed explosion-proof shell; it¡¯s safe and reliable L standard 4-20ma electric current output, compatible with existing alarm control unit or dsc (distributed control system). L imported sensor, high sensitivity, rapid response, stable and reliable Operation is simple; easy installation and maintenance Box
Kq500d intelligent gas detector is a kind of wall-mounted type detector that can be used continuously in operation environment to detect the concentration of combustion gas, oxygen, and toxic gas. The detector detects gas concentration in natural diffusion way. Kq500d intelligent gas detector transforms the gas density in the operating site into standard electric current signal(4-20ma). With led display, detector's sensor can be changed and reused as soon as it is connected to electricity. Main features: standard 4-20ma electric current output, compatible with existing alarm control unit or dsc (distributed control system). led site display that is suitable for factory (optional lcd display) L standard three buttons: so an individual can operate the detector in site. L automatic identify and display the sensor failures, and output the corresponded current signal at the same time. L the key operation needs to input password to prevent wrong operation. L simple calibration function; reducing measuring error L two levels' light alarm, relay output (connected with audible and visual alarm outside or start the exhaust system) Box
Available in both portable and fix type for all type gases, eg oxygen/lpg/organic vapour/explosive/toxic gases. -gives alarm -indicate measured gas value in digital display - multichannel gas detector with compact datalogger. Product dependent