Field Failure Relay (FFR) For D.C. Drives and Instrumentation The Field Failure Relay, when used in series with the field circuit, ensures that no power is supplied to the Armature unless Field circuit is complete. Field Failure Relay, also known as Field Loss Relay protects the D.C. Shunt motor or main circuit under open field conditions. Welcome to Insel Rectifiers: Your Premier Destination for Field Failure Relays At Insel Rectifiers, we take immense pride in being recognized as the forefront manufacturer and supplier of Field Failure Relays. Our commitment revolves around providing cutting-edge solutions that guarantee the reliability and efficiency of your systems. With a trusted legacy in the industry, we excel in the art of meticulously crafting precision-engineered Field Failure Relays and Field Loss Relays. Our dedication sets the benchmark for quality and innovation, ensuring your systems operate seamlessly and meet the highest standards of performance. Precision in Field Failure Relay Manufacturing At Insel Rectifiers, we take pride in our meticulous approach to manufacturing Field Failure Relays. These relays play a critical role in safeguarding your systems against unforeseen failures, and our commitment to precision engineering ensures that each relay meets the highest industry standards. As a distinguished Field Failure Relay manufacturer, we understand the importance of reliability in your operations. Efficient Solutions for Field Loss Relays Insel Rectifiers is your go-to source for efficient Field Loss Relay solutions. Our relay products are designed to detect and respond to field failures promptly, minimizing downtime and ensuring the seamless operation of your systems. As your dedicated Field Loss Relay supplier, we prioritize innovation to deliver cutting-edge solutions tailored to meet the unique needs of your applications. Innovative Technology, Trusted Supplier Insel Rectifiers is not just a manufacturer; we are your trusted partner in reliable relay solutions. Our commitment to innovation is reflected in the advanced technology embedded in our Field Failure Relays. As a leading Field Loss Relay supplier, we understand the importance of providing products that not only meet but exceed customer expectations. Why Choose Insel Rectifiers? Quality Assurance: Rigorous testing procedures ensure the reliability and durability of our Field Failure Relays. Innovation: We continually invest in research and development to bring you the latest advancements in relay technology. Customer Satisfaction: At Insel Rectifiers, your satisfaction is our priority. Our dedicated support team is ready to assist you with any inquiries or technical assistance.
Industrial electrical wires and cables, ups systems and ancillary, junction boxes, mccb, relays and various other electrical products and equipment..We believe in quality, cost effectiveness and timely service. we try to understand and do the best as per the client requirements.
ALSTOM GBCDG61EG040SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Relay Technical specification Relay model no CDG61EG040SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Aux.Contacts With Flag 3M S/R Output contacts 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 1.3 secs Current setting - E/F 0.5 to 2 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 5 to 20 amps High set conts.With flag CAG 13 / 2M S/R Name plate RFG9125 903 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
GBCDG61EG046SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no - CDG61EG046SGCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting O/C- 2.5 to 10 amps Contacts / Output contacts 3M S/R / 2M S/R C.T.Secondary - 5 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs Current setting - E/F - 1 to 4 amps High set - O/C Setting- 25 to 100 amps High set - E/F Setting- 10 to 40 amps High set - CAG 13 Name plate - RFG9126 904 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.27-1
Gbcdg61eg101zmch Idmt 3 O/c or 2o/c& 1 E/f Relay With Hi Model No : Cdg61eg101zm(M) Cdg61/cag17(Mrk-iii) Application - 3 O/c Burden / D.m.t - 3 Va / 3 Sec. C.t. Secondary - 5 Amp C.t. Case Size - 3d Horz. Contacts (S/r or H/r) - 2 N/o S/r Flag - Yes Frequency - 50 Hz High Set Type - Cag17 Highset Contacts - 2m S/r Highset O/c Setting - 12.5 - 100 Amps. Mounting - Flush O/c Setting - 2.5 - 10 Amps. Name Plate - Rfg9126 774 Outline Diagram - Mfj 014 Wiring Diagram - Madz821.31
Gbcdg61eg101znch Idmt 3 O/c or 2o/c& 1 E/f Relay With Hi Model No : Cdg61eg101zn(M) Cdg61/cag17(Mrk-iii) Application - 3 O/c Burden / D.m.t - 3 Va / 3 Sec. C.t. Secondary - 5 Amp C.t. Case Size - 3d Horz. Contacts (S/r or H/r) - 2 N/o 2 N/c H/r Flag - Yes Frequency - 50 Hz High Set Type - Cag17 Highset Contacts - 2m S/r Highset O/c Setting - 12.5 - 100 Amps. Mounting - Flush O/c or O/v Setting - 2.5 - 10 Amps. Name Plate Rfg9126 774 Outline Diagram Mfj 014 Wiring Diagram Madz821.32
GBCDG61EG101ZSCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI TECHNICAL SPECIFICATION Model No - CDG61EG101ZSCH CDG61/CAG17(MRK-III) Application - 2 O/C + 1 E/F Case Size - 3D Horz C.T. Secondary - 5 Amps O/C Setting - 2.5 - 10 Amps. Frequency / Tap - 50 HZ / Std Burden / D.M.T - 3 Va / 3 Sec Contacts - 2 N/O 2 N/C H/R E/F Setting - 0.5 - 2 Amps. Flag - Yes High Set Type / Contacts - CAG17 / 2 N/O S/R HighSet E/F Setting - 5 - 40 Amps HighSet O/C Setting - 12.5 - 100 Amps. Mounting - Flush Name Plate - RFG9126 903 Outline Diagram - MFJ 014 Wiring Diagram - MADZ821.32
GBCDG61EG102ZMCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Model No : CDG61EG102ZMCH CDG61/CAG17(MRK-III) APPLICATION - 3 O/C BURDEN - 3 VA C.T. SECONDARY - 1 AMP CT. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O S/R D.M.T - 3 SEC. FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET O/C SETTING - 2.5 - 20 Amps. MOUNTING - FLUSH O/C SETTING - 0.5 - 2 Amps. Name Plate RFG9126 771 Outline drawing MFJ 014 Wiring Diagram MADZ821.31
GBCDG61EG042SHCH IDMT 2 O/C & 1 E/F RELAY WITH HIGH SET Technical specification Relay model no- CDG61EG042SHCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 0.5 to 2 amps Contacts - 2M2B H/R 2M S/R Output contacts - 2M2B H/R 2M S/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs Current setting - E/F - 0.2 to 0.8 amps High set - O/C Setting- 4 to 16 amps High set - E/F Setting - 1 to 4 amps High set - CAG 13 Name plate - RFG9126 902 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.29-1
GBCDG61EG044SHCH IDMT 3 O/C RELAY WITH HIGH SET CAG 13 Technical specification Relay model no - CDG61EG044SHCH Relay type - CDG 61 Case size - 3D H 30T Application - 3 O/C Current setting - 0.5 to 2 amps Contacts / Output contacts - 2 N/O 2 N/C H/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs High set - O/C Setting - 4 to 16 amps High set - CAG 13 High set contacts - 2 N/O S/R Name plate - RFG9126 771 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.29-1
GBCDG61EG054SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG054SGCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 0.5 to 2 amps Contacts - 3 N/O S/R Output contacts - 2 N/O S/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden / Operating time - 3 VA / 1.3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C setting 4 to 16 amps High set - E/F setting 2 to 8 amps High set CAG 13 Name plate RFG9125 902 Outline drawing MFJ 014 Wiring diagram - MADZ 821.27-1
GBCDG61EG057SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG057SGCH Relay type - CDG 61 Case size - 3D HOR. Application - 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R C.T.Secondary 1 amps Frequency 50 Hz Burden / Operating time 3 VA / 3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C setting 4 to 16 amps High set - E/F setting 1 to 4 amps High set CAG 13 Name plate RFG9126 902 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
GBCDG61EG058SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG058SGCH Relay type CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 2.5 to 10 amps Contacts - 3 N/O S/R Output contacts - 2 N/O S/R C.T.Secondary - 5 amps Frequency - 50 Hz Burden / Taps - 3 VA / Std Operating time - 1.3 Secs Current setting - E/F - 0.5 to 2 amps High set - O/C Setting - 25 to 100 amps High set - E/F Setting - 10 to 40 amps High set / High set cont. - CAG 13 / 2 N/O S/R Name plate - RFG9125 903 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.27-1
GBCDG61EG101ZRCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical Specification Model No - CDG61EG101ZRCH Relay Type - CDG61/CAG17(MRK-III) Application - 2 O/C + 1 E/F Case Size - 3D Horz C.T. Secondary - 5 Amp C.T. O/C Setting - 2.5 - 10 Amps. E/F Setting - 0.5 - 2 Amps Contacts - 2 N/O S/R Flag - Yes Frequency - 50 Hz Burden / D.M.T - 3 Va / 3 Sec High Set Type / Conts. - CAG17 / 2 N/O S/R Highset O/C Setting - 12.5 - 100 Amps. HighSet E/F Setting - 5 - 40 Amps Mounting - Flush Name Plate - RFG9126 903 Outline Diagram - MFJ 014 Wiring Diagram - MADZ821.31
ALSTOM GBCDG61EG041SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG041SGCH Relay type CDG 61 Case size 3D H 30T Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Contacts / Output contacts 3M S/R / 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 3 secs Current setting - E/F 0.5 to 2 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 5 to 20 amps High set CAG 13 Name plate RFG9126 903 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ZJJ DC insulation monitoring relay monitorsthe insulation of the DC bus, and it sendsalarm signal when the bus-to-groundinsulation drops to a certain value,also it ispanel mounted type,and the relay has a high-sensitivity grounding resistance monitoringand display circuit, it is great significance forthe safe operation of the DC system. Monitoring of the DC circuit bus barinsulation resistance RF to LCD screen display resistance value. Bridge balance method for resistancemeasurement. Adjustable response value ranges of 0-100k�©. Smaller short-circuit grounding current forsafe operation.
AFR arc flash protective relay is a costeffective solution that reduces arc-fault damage by detecting the light from an arc flash and rapidly tripping in low-voltage (LV) and medium-voltage (MV) electrical networks. three remote light sensors can be connected to one relay. It used to limits damages to equipment, improve safety, avoid and protect personnel injuries. It's also can be used as a stand-alone arc protection relay or applied in more complex switchgear layouts.
Three phase 100A Latching relay TP41-10: -Three phase 100A switching capability ; -Multi layer blades, lower temperature rise ; -Conform to fault making capacity and short circuit current; -carrying capacity of requirement of IEC62066-31( UC3) and IEC61810-1. -It can be applied in three phase 100A electricity meter.
Single phase 80A Latching relay TP41-26: -Single phase 80A switching capability ; -Multi layer blades, low temperature rise ; -Environment protection ( Comply with ROHS) -It can be applied in single phase or three phase 60A Electricity meters.
Deyang YOYIK strong technical force, with CNC lathes, machining centers, 1.6M vertical lathe, 2.5M vertical lathe, 3.2M vertical lathe, 4M vertical lathe, CNC boring machine, gantry planing, gantry milling, 80mm Bending Machine and other sophisticated equipment, Strong welding capacity. Deyang YOYIK also long-term supply of power plants, steel accessories are as follows: YOYIK provides multiple types of spare parts and equipments for power plant : #DF-Relay WDZ-5271-DF Displacement Sensor(LVDT) TDZ-1E-32oil station globe check valve J15C-1.6P Oil filter fluid transfer pump YW100-250 solenoid directional valve 4WE10Y-3X/CG24N9K4 axial piston variable pump PVH098R01AJ30A250000002 O ring HY.SO.0048.V mechanical seal for pump 125-80-250 RTD temperature probe WZP2-231 pressure hose SMS-15/N1/4-915mm-C screw pump diagram HSNH440-46NZ Electric Valve 3 wire thermocouple TC03A2-KY-2B/S15 transfer pump vane F3-SV20 Temperature sensor, Pt100 WZPK2-338S Filter element SDSGLQ-68T-40 Filter element SRA-14413-T pressure hose S110-AC-FB-0150 furnace thermocouple WRNK2-231-R1/4\K pipe panel 7500mm globe throttle check valve KJC25-2.5P temperature thermocouple TE-104 three screw pump ACF090N41RBP sealing ring HB4-56J8-177 CV Disc rotary vane vacuum pump F3V201S8S1C11 oil change pump 50AY35*12 thermocouple range TE-203 coupling RE.0444R1B 0.06 EG heater thermocouple WRNK2-0901T �?5 Oil filter element outlet end of EH oil pump flange coupling 125LY-23-8 pressure hose S100-AC-AC-0080 vacuum oil pump 125LY-35-4B REGULATING VALVE DISC Thermocouple Control WRNK2-346 Relay WDZ-5271 vane vacuum pump F3-V10-IS6S-1C-20 Globe valve J61Y-320 high pressure oil pump 50SDZLJ-50 chemical centrifugal pump DFB100-65-260-03 servo valve 72559A oil station globe check valve J50C-1.6P Network Switch EKI-2528ceramic thermocouple WRNK2-331 Electrical Epoxy Insulating paint 188 Heating rod ZJ-20-3 vacuum pump 264v P-2037 thermocouple replacement TC03A2-KY-2B/S19 centrifugal pump YCZ50-250 ELECTRICAL LINEAR VARIABLE DIFFERENTIAL TRANSFORMER 1000TD Accumulator Spare parts NXQ-A-40/31.5-L-Y rtd thermocouple WRN2-239 0-600â?? screw pump manufacturer ACF080K41RBP vane pump parts F3V10-1S6S-1C20 thermocouple protection tube WRNK2-221 piston pump hydraulic PVH131Q1C.RSF.10.C25 vacuum pumps P-1758 thermocouple wzpk 230 pt100 WRNK2-391 pressure switch 1RN-EE45-M4-C1Abalanced vane pump F3-20V5A-1C22R thermistor TE-204 thermocouple k type WRNKB-446S/TG thermocouple thermometer TE-404 furnace thermocouple TC03A2-KY-2B/S3 hydraulic piston pump 80AY50*6 Relay WDZ-5271 DFYL-2022-3-17-ZYR