Spo2 sensors.
Gas sensors - complete line of instrumentation, including portables, single- and multi-point stationary instruments, stand-alone sensor transmitters, and instruments with data logging., ist's patented solid-state sensor, electrochemical sensor, infrared sensor, photoionization detector, catalytic bead sensor.
Smoke, gas, humidity & temperature and, UV sensors.
Ultra sensitive wind velocity sensor.
Pressure Control Sensors.
Abs Sensor.
Temperature sensors.
Sensors.
Sensors.
Gas Sensor, Automotive Sensor.
Sensors.
Control sensors.
Pressure sensors, gas sensors, liquid level sensors, humidity sensors, air flow sensors.
Engine Oil Level Sensor For " Porsche " Part Number : 95860616011
Left/Right Wheel ABS Speed Sensor For " Land Rover & Jaguar " Part Number : LR033457
Brake Booster Diaphragm Position Sensor For " Mercedes-Benz " Part Number : A0015401517
Engine Oil Pressure Switch For " Audi & Volkswagen " Part Number : 038919081M
DTZ-400G Series Surface Temperature Calibration System is primarily used to calibrate surface sensors of various sizes and types, such as thermistors, film sensors, surface resistance thermometers, ribbon sensors, surface thermocouples, and more. The product consists of a controller and a heater. It is easy to operate, intuitive to display, and can be heated simply by setting the temperature.The temperature rises rapidly and the multi-stage PID temperature control is accurate. The effective use range is up to 130mm in diameter and has a communication interface to communicate with the computer. This product can be used as an infrared camera calibration source if it is slightly changed. Product Features 1.The calibration temperature can reach 400 The temperature rises and the temperature drops quickly. DTZ-400 surface temperature calibration system has a good temperature rise and fall, from room temperature to 400, only 30 minutes, from 400 to room temperature, with a rapid cooling device only 50 minutes, greatly improving work efficiency . 2.Calibration plate diameter up to 130 mm, meeting most surface temperature sensor calibration needs 130mm and is sufficient for calibrating surface sensors of various sizes and types, such as thermistors, film sensors, surface resistance thermometers, ribbon sensors, surface mount thermocouples, etc. 3.External reference platinum resistance thermometer to reduce calibration uncertainty In order to achieve the ultimate in calibration accuracy, the design engineer deliberately reserved a thermometer socket at the bottom of the aluminum surface. platinum resistance thermometer with a diameter of 5 mm can be inserted as a standard for comparison and calibration, which greatly improves the calibration accuracy. 4.Excellent uniformity of temperature and surface finish on the calibration plane Surface sensors are often difficult to calibrate because it is difficult to find a flat, uniform source of surface temperature.The DTZ-400 Surface Temperature Calibration System utilizes aluminum as the surface and has a high finish that ensures that the calibrated sensor is in good contact with the surface temperature calibrator, reducing calibration uncertainty. The DTZ-400 uses a special heating material and a constant temperature structure to make the surface temperature more uniform. 5.Temperature control is accurate, stable, and overshoot temperature is small The device provides a variety of parameter options for the user to choose, including setting the PID parameters of the high,medium and low temperature segments, the inflection point between different temperatures, and the alarm temperature. 6.Portable and easy to use The weight of the whole machine is only 3.5kg, which is small and portable.
TADT portable humidity generator is a portable and high-precision temperature and humidity calibration instrument, which can meet the needs of measurement and calibration of conventional temperature and humidity measuring instruments such as temperature and humidity sensors, temperature and humidity transmitters, small temperature and humidity meters, etc. Functional characteristics * Test chamber space up to (3~5) times that of similar products, providing more efficient test conditions * The test chamber can accommodate various types of in-put cold-mirror-viewer probes for comparison and calibration * Composite sensor jack design, suitable for various diameter temperature and humidity sensors and transmitters * Transparent window and lighting design of measuring room to facilitate reading of various small temperature and humidity meters * Can be calibrated simultaneously (10~15) with small temperature and humidity probes * Calibrate (3-5) block size digital temperature and humidity meter simultaneously * The test chamber provides temperature uniformity within 0.1 in a full range of 5~50 * Design of external drying cylinder, desiccant replacement can be operated on-line, convenient and simple * Design of double-zone drying cylinder, supporting both molecular sieve and discolored silica gel * Visual display of liquid level and dryer state is beneficial to state monitoring during work * Provide 4 channel external (0~1) Vã??(0~5) V and (4~20) mA standard signal inputs * The instrument has built-in humidity conversion software to facilitate users to convert relative humidity, temperature and dew point temperature * Support temperature and humidity curve display, easy for users to view temperature and humidity state trend * 7-inch color LCD touchscreen
Specifications: Construction: open structure Using method: transmitter/receiver Center frequency: 23 +/- 1.0khz Sound pressure level: 115 db min. Sensitivity: -67 db min. Capacitance: 2500pf +/- 20% at 1khz Allowable input voltage: 80 vp-p Directivity: 50 +/- 15 degree Detectable range: 0.2 ~ 15m Resolution: 10mm Housing material: aluminum Carton lined with foam tray