TADT portable humidity generator is a portable and high-precision temperature and humidity calibration instrument, which can meet the needs of measurement and calibration of conventional temperature and humidity measuring instruments such as temperature and humidity sensors, temperature and humidity transmitters, small temperature and humidity meters, etc.
Functional characteristics
* Test chamber space up to (3~5) times that of similar products, providing more efficient test conditions
* The test chamber can accommodate various types of in-put cold-mirror-viewer probes for comparison and calibration
* Composite sensor jack design, suitable for various diameter temperature and humidity sensors and transmitters
* Transparent window and lighting design of measuring room to facilitate reading of various small temperature and humidity meters
* Can be calibrated simultaneously (10~15) with small temperature and humidity probes
* Calibrate (3-5) block size digital temperature and humidity meter simultaneously
* The test chamber provides temperature uniformity within 0.1 in a full range of 5~50
* Design of external drying cylinder, desiccant replacement can be operated on-line, convenient and simple
* Design of double-zone drying cylinder, supporting both molecular sieve and discolored silica gel
* Visual display of liquid level and dryer state is beneficial to state monitoring during work
* Provide 4 channel external (0~1) Vã??(0~5) V and (4~20) mA standard signal inputs
* The instrument has built-in humidity conversion software to facilitate users to convert relative humidity, temperature and dew point temperature
* Support temperature and humidity curve display, easy for users to view temperature and humidity state trend
* 7-inch color LCD touchscreen
DTLH low humidity intelligent temperature and humidity standard chamber is a special verification equipment for detecting hair temperature and humidity meter, dry and wet bulb thermometer, digital temperature and humidity meter and other kinds of temperature and humidity sensors. The equipment can automatically adjust the humidity in the temperature and humidity verification box by accurate measurement of temperature and humidity sensor and industrial programmable controller control. High control and testing accuracy, can provide continuous, repetitive humidity measurement, suitable for scientific research and product testing. Advanced technical principles * Humidity control adopts the principle of moisture occurrence by shunt method, which greatly shortens the time required for stability and improves the verification efficiency compared with the principle of humidity occurrence by double temperature method. * Temperature control using liquid bath constant temperature plate heating technology, liquid medium heat radiation, temperature more constant, temperature field more uniform * The unique air circulation design in the measuring chamber ensures no dead angle air flow, and adopts frequency conversion technology to speed the fan to ensure that the internal temperature field is uniform at low speed; Product intelligence * Fusion of measurement technology and Internet of things technology to wifi remote control to make measurement easier * HD touch screen control, multi-touch, greatly improve user experience, * One-click start, automatic control, shorten the training period for metering personnel * Timing switch machine, remote switch machine, save time, improve verification efficiency Excellent quality * The shell adopts thick plate phosphating, passivation, spray molding, anticorrosion, rust prevention, salt spray resistance; * SUS304 for internal bile * High precision sensor, temperature and humidity control with imported high precision * With intelligent image acquisition system, dew point meter and industrial control computer, it can be upgraded to intelligent temperature and humidity meter automatic verification system to realize the automation of verification process, the automatic preservation of records and the automatic generation of reports.
I. Product introduction The DTBH zero-temperature thermostat is a device that can provide a stable and accurate zero-degrees Celsius temperature field for the thermocouple reference end for a long time. It is an ideal substitute for the traditional ice bucket and is very suitable for the verification / calibration of thermocouples. The technical specifications of the equipment are in full compliance with the new regulations "JJF1637-2017 Low-cost Metal Thermocouple Calibration Specification". II. Product technical indicators Model DTBH-01 DTBH-03 Accuracy 0±0.05 0±0.03 resolution 0.001 0.001 stability 0.02/10min
Supplier: Industrial X-Ray machine ( portable X-ray generator, pipeline crawler, Hardness tester, Portable DR image system, industrial CT, XRDXRF,Crystal orientation instrument)
Supplier: Humidity and temperature sensor, transmitter, alarm monitor, flame detector, portable calibrator, hydraulic and pneumatic pressure meter, vibration meter
Buyer: Hose pipe, water membrane, pump
Supplier: Solar panels, solar air conditioner, solar pumps, air conditioner, portable air conditioners, LED lighting, LED street lights, construction equipment, hydraulic tools, generators
Buyer: Solar related products
DTZ-400G Series Surface Temperature Calibration System is primarily used to calibrate surface sensors of various sizes and types, such as thermistors, film sensors, surface resistance thermometers, ribbon sensors, surface thermocouples, and more. The product consists of a controller and a heater. It is easy to operate, intuitive to display, and can be heated simply by setting the temperature.The temperature rises rapidly and the multi-stage PID temperature control is accurate. The effective use range is up to 130mm in diameter and has a communication interface to communicate with the computer. This product can be used as an infrared camera calibration source if it is slightly changed. Product Features 1.The calibration temperature can reach 400 The temperature rises and the temperature drops quickly. DTZ-400 surface temperature calibration system has a good temperature rise and fall, from room temperature to 400, only 30 minutes, from 400 to room temperature, with a rapid cooling device only 50 minutes, greatly improving work efficiency . 2.Calibration plate diameter up to 130 mm, meeting most surface temperature sensor calibration needs 130mm and is sufficient for calibrating surface sensors of various sizes and types, such as thermistors, film sensors, surface resistance thermometers, ribbon sensors, surface mount thermocouples, etc. 3.External reference platinum resistance thermometer to reduce calibration uncertainty In order to achieve the ultimate in calibration accuracy, the design engineer deliberately reserved a thermometer socket at the bottom of the aluminum surface. platinum resistance thermometer with a diameter of 5 mm can be inserted as a standard for comparison and calibration, which greatly improves the calibration accuracy. 4.Excellent uniformity of temperature and surface finish on the calibration plane Surface sensors are often difficult to calibrate because it is difficult to find a flat, uniform source of surface temperature.The DTZ-400 Surface Temperature Calibration System utilizes aluminum as the surface and has a high finish that ensures that the calibrated sensor is in good contact with the surface temperature calibrator, reducing calibration uncertainty. The DTZ-400 uses a special heating material and a constant temperature structure to make the surface temperature more uniform. 5.Temperature control is accurate, stable, and overshoot temperature is small The device provides a variety of parameter options for the user to choose, including setting the PID parameters of the high,medium and low temperature segments, the inflection point between different temperatures, and the alarm temperature. 6.Portable and easy to use The weight of the whole machine is only 3.5kg, which is small and portable.
Parameters: - voltage ranges from 1.4 V up to 750 V, - current ranges from 5 mA up to 100 A with a galvanic insulation of outputs, - frequency ranges from 40 Hz up to 1250 Hz, - power generation from 0 W up to 3 x 75 000 W, - voltage and current accuracy 0.05%, - power and energy accuracy 0.8%, - harmonic course generation, - synchronization with supply frequency, - RS-232C, IEEE488 interfaces, - measurement of DC voltage and current up to 10 V and 20 mA, - setting optional parameters: U, I, P, E, cos, t. INMEL 8033 Calibrator is a three-phase electric power and energy calibrator. It generates voltages of equal rms value on three voltage outputs and currents of equal rms value on three current outputs. The voltage on voltage output and the current on current output are shifted between them by set phase angle. Against to the previous model calibrator type INMEL 33, the new device INMEL 8033 one characterize less voltage, current, power and angle generation error, has also wider frequency range of quantity generate and richer program function set. The most important from program functions is the possibility to generate harmonic course. The main distinctive feature of INMEL 33 from INMEL 8033 is digital method measurement generating and stabilization output signals. Application: Checking ang calibration: - Wattmeters, varmeters, - phase meters, - frequency meters, - AC of voltmeters and ammeters, - power factor and phase angle meters, - measuring transducers, - watt-hour meters in single and three-phase system, - power engineering protections.
Parameters: - simulation and measurement: thermocouple signals J, K, T, R, S, B, U, L, E, N, with auto-compensation of terminal temperature, signals in thermocouple and thermostat system, resistance thermometer signals: Pt 100, Pt 500, Pt 1000, Ni 100, Cu 100, resistance signals from 10 up to 5 , voltages and currents in range: -11 V...+11 V and 22 mA...+ 22 mA - accuracy 0.025% - STEP and RAMP function, - led out 24 V terminals, - RS 232C interface, - available in the option for pressure calibration. The INMEL 60 calibrator is destined to check and control systems, industrial automatic control engineering devices such controllers, recorders, meters, etc. This instrument has the possibility to generate and measure signals from ten thermocouples, five thermometer resistances, four voltage ranges, two current ranges, two resistance ranges. Thermoelectric terminals have an internal temperature measurement and for this reason make possible the generation or measurement of thermoelectric signals with the compensation for the given thermocouple. In this working mode, a real thermocouple is added to thermoelectric measuring terminals, and compensation conductors to thermoelectric generating terminals. The calibrator ensures the simultaneous generation of the signal on output terminals and the measurement of the signal on measuring terminals, thanks to this feature the calibrator is suitable to check transducers. The INMEL 60 calibrator enables to check two-wire transducers. the used graphical display contains a lot of information on a screen with a good readability. The display ground-lighting, which can be switched off, is especially useful in conditions of an insufficient lighting. The internal supply from the battery enables the work not only in laboratory conditions but also on the object. The calibrator can also be used to the maintenance and servicing of industrial measuring instruments, systems and electronic equipment. Application: Checking and calibration: - measuring transducers controlled by a voltage or current signal, a thermoelement or resistance thermometer, - two-wire transducers, - temperature meters, - pressure transducers, - manometers, - measuring and control lines.
Technical parameters: - Voltage ranges from 200 V up to 1000 V, - Current ranges from 200 A up to 20 A, - Frequency ranges from 20 Hz up to 100 kHz, - Resistance from 1 up to 19 M, - Voltage accuracy from 35 ppm, - Current accuracy from 150 ppm, - Ample software, - High output load, - RS 232C , IEEE488 interfaces. The INMEL 7000 calibrator is device with very high precision and simultaneously high load, thanks that it pulls ones weight very well with checking modern type as well older types of meters. It is characterized elastic and open systemic structure. We offer varius version of this calibrator from very simple e.g the DC voltage calibrator up to full configuration : DCV, DCI,ACV,ACI and R. Thanks to ergonomic desc and rich internal software the INMEL 7000 calibrator is very handly. In calibrator INMEL 7000 used modern construction solution, in which used new generation of electronics elements of renowned worldwide companies. Thanks that ones received very good metrological parameters, reduced quantity of compnents, and in this way augment the reliability of this calibrator. Application: Checking and calibration: - AC and DC voltmeters, - AC and DC ammeters, - frequency meters, - measuring transducers, - ohmmeters.