Moisture meter mc7806 Model: Moisture meter mc7806 Measurement range: moisture content 0-50% Temperature +c10-60f Resolution: 0.1 Accuracy: Moisture: f+(0.5%n+0.1) Temp: f+0.8f Calibration: automatic Power supply: 4x1.5v aa (um-3) battery Dimensions: 182x68x38mm Probe dimension: 170x44x25mm Weight (not including probe):334g Dimensions: 182x68x38mm Probe dimension: 170x44x25mm
Coating thickness meter cm-8823 Application: Product synopsis Measurement range 0200um/500um/1000um/15000um Resolution 0.1/1 Tolerance +(13%n) or +2um Power supply 4x1.5v aa(um-3)battery Dimension 161x69x32
Tachometer Eatures: Measuring rpm is safe & accurate without attachment to object. Wide measuring range & high resolution. Digital display gives exact rpm with no guessing or errors. Used the exclusive micro-computer lsi-circuit and crystal time base to offer the high accuracy measurement & fast measuring time. The last value/max. Value/min. Value will be automatically stored in memory and can be displayed by turn. The use of durable, long-lasting components, including a strong, light weight abs-plastic housing assures maintenance free performance for many years. Product synopsis Model: dt Measuring range: rotative velocity laser . - r/min Contact . - r/min Laser tach detecting distance: - mm Accuracy: f+( . %n+ d) Resolution: . / . / Memory: max/min/last value Power supply: x . V aa (um- ) battery Battery indicator: low battery indicator Dimensions: x x mm Weight (not including probe): g
Digital panel meter Digital panel meter which is various and artistic in appearance design is used for dual slope, high precise a/d changeover circuit and high light led cassette setting specification. It is very convenient for user to fix the equipment.
We offer many kinds of industrial measuring instruments and meters, you are welcome to link to: www.Windofwest.Diytrade.Com for more information. Cartons
Single phase long life electronic energy meter Major technical data: Name of product: single phase long life electronic energy meters Type: dds 318 Accuracy class: 1.0 Power consumption :< 6va Rated voltage: 220v 240v Rated current: 2.5(10) a 5(30) a 10(50) a Application: By adopting advanced pcb and smt technology, dds318 single phase long life electronic energy meter is used to measure the energy of 50hz single phase a.C power. Salient feature: 1.High accuracy:1.0class 2.High overload capacity: 6 times of overload. 3.High reliability: long operating life. 4.Low power consumption, small size, light weight, tamper proof and easy to install. 5.Smt and re-flow soldering technology is adopted. Meter has strong capability for disturbance. Emc can comply with requirement of iec61036-2000. 6.With impulse output interface for direct calibration of the meterf+s accuracy, or for measurement of the impulse input in case of mass-metering. 7.Power indicator to test the optical power end and calibrate the accuracy of the meter. 8.Electric power line carrier system and telephone remote-metering system can be supplied for userf+s option. 9.It can be changed into single phase plc electronic energy meter
Features: 1) high accuracy, reliability, overload capability 2) low power consumption 3) smt technology and re-flow soldering technology Major technical data: 1) accuracy class: 1.0 2) power consumption: less than 4va 3) rated voltage: 200v 4) rate current: 2.5(10)a, 5(25)a, 10(40)a Main functions: 1) measurement of single-phase 50hz active power and power consumed 2) set up maximum load, overload warning and power off 3) warning of remained energy and remind user for payment 4) re-read power consumed, remained energy and number of prepayments for power 5) power off when no energy in the meter 6) parameter transferring through ic card Salient features: 1) high accuracy: 1.0 class 2) high overload: 6 times of overload 3) high reliability: long operating life 4) low power consumption, tamper-proof, light weight, small size and easy to install 5) register displays consumed power, and led displays status of consumed power 6) smt technology and re-flow soldering technology are adopted. Meter has strong Capability for disturbance. Emc can comply with requirement of iec 61036-2000 High overload capacity, high reliability of relay Single-phase and 3-phase pre-payment electronic energy meters can share one set Light weight, small size, easy to install Of prepayment control system
DIGITAL MULTIMETER Range Accuracy Dc voltage 200mv-500v (0.5%+2dgt) Ac voltage 200-500v (1.2%+10dgt) Dc current 200µa-10a (1%+2dgt) Resistance 200 +-2000k+ (0.8%+2dgt) Diode test Yes Transistor test Yes Power supply 12v battery a12 Maximum display 1999 Products size 100,-50,-20mm Product net weight 58g Standard accessories Test lead, battery, manual
Digital multimeters DC V 400mV/4V/40V/400V/1000V Basic accuracy 0.3%+5d AC V 400mV/4V/40V/400V/700V Basic accuracy 0.75%+10d DC Current 40mA/400mA/4A/20A Basic accuracy 1.2%+10d AC Current 40mA/400mA/4A/20A Basic accuracy 1.2%+10d Resistance 400+/4K+/40K+/400K+/4M+/40M Basic accuracy 0.5%+10d Capacitance 40nF/400nF/4uF/40uF/100uF Basic accuracy 2.0% Data hold Min/Max/Avg. Measurement Peak Hold Continuity test Diode test Low battery sign Backlight Signal output Frequency Counter 0.5Hz-45MHz Basic Accuracy 0.1%+5d Automotive RPM 0-12000RPM Duty Cycle 0-100% Dwell 2/4/5/6/8/12 Logic Analyzer 2/4/5/6/8/12 Power Source 6 -1.5V AA or 6 -1.2V A
Airflow meter
MF5000 series Gas Mass Flow Meters General description MF5000 series mass flow meters are specially designed for small pipe flow monitoring and feature an extremely low pressure loss compared to the traditional by-pass thermal mass flow meters in this application scope. The accuracy of the meters are generally (1.5+0.5FS)% or better depending on the requests. The meters can work at an environment of -20 to 60'C and pressure up to 1.5 MPa. Applications include semiconductor gas process monitoring and control, hospital oxygen gas monitoring, etc. MF5000 Series have 5 designs, with model number: MF5003/MF5006/MF5008/MF5012/MF5019. MF5000 series Gas Mass Flow Meters Features and Applications - Highly sensitive, measuring as low as 8 mm/sec, and as high as 65 m/sec with a single assembly - Directly sense mass flow using thermal mass flow principle - Proprietary MEMS sensor package design for better reliability - Standard 12 ~ 24 Vdc power supply - Low pressure loss forreducing energy cost - Industrial standard Modbus protocol for easy networking and remote control MF5000 series Gas Mass Flow Meters Specifications * â??Accuracy: (1.5+0.5 FS)% * Environment: - Temperature: -20 ~ +60'C; - Humidity: < 95%RH (No icing or condensation ) * Flow channel: 3 ~ 19 mm * Display: Flow rate and accumulated flow * Interface: 4 ~ 20 mA; RS485; Pulse * Calibration: Air @ 20'C; 101.325 kPa
Prepaid meters are now, The government is also taking initiative and making policies to make it happen. Commercial establishments like offices, retail, industrial, multifamily, malls, complexes can install prepaid meters. With Adwards Intellitech Pvt Ltd you don't have to bargain, we provide Low cost prepaid meters for all commercial establishments. Our prepaid meter is flexible in adapting to the ever-changing requirements and conditions.
Flowmeter We are a leading name in this domain engaged in manufacturing and supplying a broad array of Flow Meter. These are fabricated using finest grade material and innovative technology, our products are acknowledged for their sturdy construction, convenient operation, easy maintenance and elongated service life. Our components for the product are procured from some of the most reliable vendors so as to provide our clients with best-in-class-products. Electromagnetic FlowmeterWe are manufacturing, exporting and supplying a comprehensive range of Electro Magnetic Flow Meter or Electromagnetic Flowmeter, which is used for electrical measurement of flow rate. The performance of the instrument is not affected by the properties of the material such as corrosiveness, viscosity, density, acidity and alkalinity. Description : Flow Star series FEMAG are micro-controller based full bore type electromagnetic flow transmitter specially used for various industrial applications These flow transmitters accurately measures the flow rate of conductive liquids & slurries in closed pipes Due to simple & rigid design the flow transmitter is an obstruction less & maintenance free instrument in place of conventional mechanical flow measuring device The use of 'Pulsed DC' technology offers highest ability & better measuring accuracy in the form of electrical signal 4 - 20 ma DC linearly proportional to volumetric flow The instrument is based on Faraday's law of electro-magnetic induction. A magnetic field is generated by the instrument in the flow tube The fluid flowing through this magnetic field generates a voltage that is proportional to the flow velocity. Corresponding electrical output is provided with respect to measuring voltage Salient Features : Indication through LED / LCD Full Bore type Microprocessor based Simple & cost effective construction Provides wide flow ranges Outstanding accuracy Operates over wide ranges of temperature & pressure Easy maintenance as no moving parts Pulsed DC coil excitation Flame-proof, IP-65, IIA, IIB CMRI certified housing
Vasthi uses heated probe to collect the sample from the sample line, it will maintain constant temperature and removes the dust and mist from the sample gas. This gas sample passes through electrically heated tube to cooler. It will remove the vapour content and cools the gas sample to 5áµ?c dew point range and this sample gas goes through the filter that eliminates the dust particle remaining and finally sensor senses and gives the exact readings in syngas analyzer.
This instrument adopts the pulse xenon lamp as light source and the ultraviolet optical fiber spectrometer as detector is capable for real-time gathering of absorption spectrum of water pollutants ranging from 200nm to 800nm and real-time analysis of the content of water pollutants by means of chemometric algorithm technology. Optical path as shown below.For more information.
Electrical measure and control.