Fuse holder, insulator, surge arrestor, current transformer, epoxy resin insulation.
HV apparatus.
Ese lightning arresters, exothermic welding, earthing chemical compounds.
Chemical earthing and lightning arrester.Manufacturer & exporter
Solid State Decoupler, Spark Gap, Metal Oxide Arrester, Surge Protector.
Composite Insulators, Composite Gapless Metal Oxide Surge Arresters, Fuses, Disconnectors, Vacuum Circuit Breaker, Safety Tools Production .
Silicone insulator, suspensior insulator, pin insulator, line post insulator, bushing, post insulator, insulator switch, polyethylene pin type insulator and accessory, cable cover, pin post housing, silicone surge arrestor, fust cut out switches, line fitting, cut out fitting & accessories, end fitting for insulator.
We are manufacturer of 1. chemical poer earthings 2. lightining arrester 3. surge protection device 4. transformer and gyser.
Lightning arrester, earthing, gas generator.
Overview zinc oxide arrester tester is a special instrument used to test the electrical performance of zinc oxide arrester. The instrument is suitable for live or power failure detection of zinc oxide arrester of various voltage levels so as to timely detect the internal insulation damp and valve aging and other dangerous defects. zinc oxide arrester tester is easy to operate and easy to use. The whole measuring process is controlled by single chip microcomputer. It can measure the total current resistive current and its harmonics power frequency reference voltage and its harmonics active power and phase difference. The instrument uses digital waveform analysis technology harmonic analysis and digital filtering software anti-interference methods to make the measurement results accurate and stable. Parameter: 1. Full current measurement range: 0-10mA effective value 50Hz/60Hz accuracy: (reading 5% + 5a) 2. Measurement accuracy of resistive current fundamental wave (secondary method without Interphase Interference): (reading 5% + 5a) 3. Current harmonic accuracy: (reading 10% + 10a) 4. Reference voltage input range: 25V-250V RMS total harmonic content 30% 50Hz/60Hz 5. Reference voltage measurement accuracy: (reading 5% + 0.5V) 6. Voltage harmonic measurement accuracy: (reading 10%) 7. Angle between fundamental current and fundamental voltage: 0-360 8. Working time of battery: 6 hours of main engine charging power supply: 220 V 10% 50Hz/60Hz charging time: 5 hours 9. Host volume: 325 280 140 10. Host weight: 3.5kg (without cable)
Surge Protection Devices, Lightning Arresters.
Surge Protection Devices, Lightning Arresters.
Electric power fittings, polymer insulators, cable accessories, lightning arrester, and fuse cutout..
Transformer bushing, condenser bushing, porcelain insulator, composite insulator, glass insulator, bushing metal accessories.
High voltage fuse cut out, high voltage lightning arrester, fuse link, disconnecting switch, polymer insulator.
Low voltage electrical products such as miniature circuit breakers, isolator switches, residual current circuit breaker, lighting arrestor, din rail, metal distribution boards.
Lightning Arrester, Lightning Rod, Grounding Wire, Grounding Clamp, Lightning Arrester.
Fuse cutout, load break fuse cutout, lightning arrester, MCB, Mccb, lbs, rmu, voltage transformer, current transformer, insulation tape.
Mv & lv power control cables and instrumentation cables, cable jointing kits, repair kits, la, abc connectors, surge arresters, mv switchgears (11 & 33 kv vcb, gis, ais, rmu, pss/css, vi, relays, ct & pt.
Product description The metal oxide arrester tester is used for the measurement and analysis of metal oxide arrester MOA leakage. It is mainly used for measuring the resistive current to analyze the degree of zinc oxide aging and damp. The field charged test shall conform to Electric Power Industry Standard of the People's DL474.5-92 Guide for Insulation Test on Site - Lightning Arrester Tests. The metal oxide arrester tester can be also used for factory and acceptance tests. Zinc oxide arrester tester Technical Indexes Range of reference voltage input peak 10V-200V Measurement range of full leakage current peak 100uA 10mA Measurement range of resistive current peak 100uA 10mA Measurement range of capacitive current peak 100uA 10mA Measurement range of angle 0-90 Power consumption 4W System measurement accuracy reading 5 5 words not more than 2m for harmonic current AC power supply AC 220V 10 50Hz 1 Precautions When measure the reference voltage from PT or the measuring end of the testing transformer, carefully check wiring to avoid the PT secondary or test voltage short circuit. Be careful not to wrongly connect the current and voltage sampling lines in the connecting process. In the laboratory experiment, the high voltage power supply cannot use the series excitation testing transformer.