Type k high voltage fuse link for dropout fuse cutout. 1). Product description: This fuse wires apply to the 11kv -36kv drop out fuse. 2). Standard: According to ansi/ieee c37.41-2000 and iec-282 standard. 3). Technical specification: Rated current: 1a-300a Rated voltage: 11kv-27kv Length: 530mm-600mm (23 inch) Length of fuse link can be make according to requests. 500pcs a carton
Supplier: Micro silica (silica fume), silica, fly ash, pozzolano, ggbfs and white cement, other cementatious materials and factory/plants specialized spare parts & equipments, automation & switchgear, drives & transmission spares, instrumentation & pump, pneumatic & hydraulic spares, valves & actuators, mechanical parts, high carbon ferro chrome, foundry pig iron, iron ore concentrate, chromite ore, antimony ore, silicon metal 441 (powder), ferro silicon (fesi), iron ore pellet, copper concentrate
Application Use for control and connecting cable on data transmission within building management system, speaker audio system and control measurement. Suitable for use in dry and damp environment. Cable Structure & Features Conductor Material : Tinned copper stranded Insulation : Semi-Rigid PVC Drain Wire : Tinned copper stranded Shielding : Aluminium foil laminated screen Outer Sheath ; PVC Sheath Colour : black or gray Technical Data Standard : UL Style 2464 Approvals : UL apporoved Rated Voltage : 300V Testing Voltage : 1500V Flame Retardant : VW-1 Insulation Resistance : Min 20Mx km Min. Bending Radius : 10 x cable diameter Operating Temp. : -30C / +80C
CIRCULLATION FAN Air cooling fans are used for maintaining good air circulation and temperature in poultry farms. Our 36 air circulating fans can be used for various applications, like poultry farms, industrial buildings etc., and providing high efficiency. These fans are available in both single phase and three phase motor option. 1.Grills are plastic coated and thick diameter wire gauge (2.5mm) is used, and the gap is maintained 15mm as per international quality standards to avoid human accidents and rate entering into the fan. 2. The blades are made of compounded plastic so less chances of bending and hence less breaking chances. 3. Motor is efficient and complete thermal protection and moisture proof. 4. The CFM of fan 13000 and minimum airflow of 8.5 meters/sec. 5. Minimum positive air throws of 50ft. When we say 50 Length in practically. 6. Easy installation &Zero Maintenance
1. Use (H) RW 12-27 drop fuse and pull-load drop fuse are outdoor high-voltage protective appliances, which are assembled on the high-voltage side of distribution transformer or branch lines of distribution line, and are used for overload and short-circuit protection of transmission lines and power transformers and for sharing rated load current. 2. Brief introduction of structure The drop fuse consists of two parts: insulating bracket and fuse pipe. The static contacts are installed at both ends of the insulating bracket, and the movable contacts are installed at both ends of the fuse pipe. The fuse pipe consists of an inner arc extinguishing tube and an outer epoxy glass tube. Pull-load drop fuse adds elastic auxiliary head and arc extinguishing cover to divide and close load current. When a drop fuse is in normal operation, the fuse pipe is tensioned by means of the fuse. Then a closed position is formed. When the system fails, the fault current causes the fuse to fuse rapidly and form an arc. The arc extinguishing tube is heated by the arc and decomposes a large number of gases, which forms a high pressure in the tube and blows longitudinally along the pipeline. The arc is rapidly elongated and extinguished. After the fuse is fused, the lower moving contact loses tension and turns down. The locking mechanism releases the fuse tube, and the fuse tube falls down, forming an obvious breaking position. When the load needs to be pulled, the contact is pulled by the insulating rod. At this time, the active and static contacts are still in contact. The contacts are pulled by the insulating rod, and the auxiliary contacts are separated. Arc is generated between the auxiliary contacts. The arc is elongated in the slot of the arc extinguishing hood. At the same time, the arc is extinguished when the current passes zero. 3. Implementation criteria The product performance conforms to GB15166.3-94 national standard and IEC282-2 international standard. 4. Conditions of Use 1. Environmental temperature: - 40 ~40 C; 2. No more than 1200 m above sea level; 3. The wind speed is not more than 35m/s. 4. Earthquake intensity does not exceed 8 degrees. 5. Fuses are not suitable for the following places: A. Places where there is a danger of combustion or explosion; B. Places with violent vibration or shock; C. Areas with heteroelectrochemical gases, severe air pollution and salt fog. 5. Instructions for Order 1. Product type, name, rated voltage, rated current and rated switching-on current; 2. Environmental requirements (anti-pollution, plateau type); 3. Special requirements can be consulted with our company. Manufacturer of intelligent switch cabinet--low-voltage, high voltage power distribution switch cabinet, also have many other electric equipment electric power accessories, intelligent transmission and distribution automation system