The hot wound spring coiler also called hot coiling machine for heavy duty springs such as locomotive springs or car springs or leaf springs with cnc three servo control (principal axis , pitch, helix angle orientation)is controlled by the spanish fagor cnc system and starts, clamps and unwinding automatically. The machine researched by wintime machinery co., ltd is available for both left and right turn compression springs like heavy duty springs for railway .Taped or round bar is fed.
This machine is produced in wintime machinery co., ltd. It can test a variety of heavy duty springs such as locomotive springs¡¡écar springs or leaf springs. This testing machine mainly use computer and software to control the whole system, which can make the accuracy more precise. The hydraulic cylinder is imported from germany, which is high flow, good circularity and high availability. This machine can be used to test the heavy duty springs of haulage motor. This machine can adopt the electro-hydraulic servo testing system to operate. The all parts of equipment can be maintained and repaired. The main functions of this machine is as follows, it can use fixed deformation or fixed load. Measurement system can be automatic zero, automatic calibration. Computer real-time display test amplitude, test frequency, the number of fatigue. The load capacity is up to 500kn, and the test space is about 600mm(wide)* 1700mm(length), which can be adjust up and down. The max.Test amplitude is ¡¨¤40mm, and the frequency is about 0.1hz to 4hz. The maximum power should be 380 v ac, 110 kw. This machine can match different kinds of heavy duty springs such as locomotive springs¡¡écar springs or leaf springs.
DMF Mass Flowmeter is mainly used in food industry (dairy product, liquor, drink, syrup, chocolate, cooking oil), chemical industry (olefin, light olefin, naphtha and diesel oil, arene, LPG), fine chemical industry (salt chemical industry, resin industry, chemical additives), pharmaceuticals industry (material producing, testing), logistics industry (all kinds of chemical material, oil) 1. Main Technology Parameters /cm3 Repeatability: 0.10% Signal output: 4~20mA load resistor £¼ 500¦¸ (real-time flow rate or density ) 0~10 KHz real-time flow pulse signal 485 communication signal Sensor explosion-proof grade: Exib(ib)IIBT2~T5 Transmitter explosion-proof grade: Exib(ib)ibI BT5 Flow Range For small and middle style Item No. Caliber£¨mm£© Measurement Range (kg/h) Operating Pressure£¨Mpa£© Connection£¨mm£© Welded DMF-1-1-A 3 4-40 32 ¦µ6¡Á1.5 DMF-1-1-B 6 10-100 25 ¦µ10¡Á2 DMF-1-2-A 7 20-200 20 ¦µ10¡Á1.5 DMF-1-2-B 10 40-400 25 ¦µ14¡Á2 DMF-1-3-A 12 50-500 4 ¦µ18¡Á3 12 25 ¦µ20¡Á4 DMF-1-3-B 14 100-1000 4 ¦µ18¡Á2 14 25 ¦µ20¡Á3 DMF-1-4 16 300-3000 4 ¦µ18¡Á2 16 25 ¦µ20¡Á4 Individual in polybags, inner plastic boxes, out plywood cartons(wood cartons),any special required packings can be specified as well(customization).
Lde electronic magnetic flowmeter is mainly used in oil, chemical industry, metallurgy and other fields. And it can be measure the liquid which conductivity is equal or greater than 5us/cm. There is no moving parts or loss of pressure in the close tube and the measurement will not be affected by the density, viscosity, temperature, pressure and conductivity of the liquid. The lining and electrode materials are manufactured with good corrosion resistance and abrasion resistance. Adopt a novel way of excitation. Low power consumption; stable zero point and high accuracy. This kind of item is applicable for industries like oil, chemical, power supply, textile, food, paper making, environmental protection, water conservancy construction, especially the field of sewage treatment. Individual in polybags, inner plastic boxes, out plywood cartons(wood cartons), any special required packings can be specified as well(customization).
Main features A. Single chip technology, powerful function, high accuracy. B. Lithium battery for energy source, as long as two years or longer. C. Instant flow and total flow are easily showed on the screen, and all the data will be remembered for more than ten years though the product powered off. D. Simple structure, easy installation, operation and maintenance. And password protection. E. Data is amended automatically and high accuracy. F. Clear in reading, simple operation and maintenance. G. Explosion-proof. Main technology parameters Accuracy: ¡¾0.2% ¡¾0.5% ¡¾1.0% Caliber: dn15~dn500mm Pressure: 1.6~6.3mpa. ¡ã10mpa Measurement range: 0.4~4000m©ø/h Connection type: thread connection (dn15~dn40mm) flange connection(dn15~dn500mm) Energy source: 1) a lithium battery inside- no output; 2) 24vdc outside- 4~20ma output Explosion-proof grade: exd¥±bt5 Individual in polybags, inner plastic boxes, out plywood cartons(wood cartons), any special required packings can be specified as well(customization).
Ht-1000b supersonic flowmeter series is manufactured by modern technology, which is the first choice for the industries, the measurement principle of which is based on the difference of the flow speed. They're mainly used to measure the volume flow of the conductive fluid and slurry in a closed tube. With some characters such as good m Language menu Chinese and english are available for reading. Energy source Ni-mh, rechargeable, large capacity, which could easily, ensured the flowmeter work more than 20 hours. Printer inside Print the data real-time, as well as the results according to customer comments. Data recorder inside This could load all the results into the computer and internet. Individual in polybags, inner plastic boxes, out plywood cartons(wood cartons), any special required packings can be specified as well(customization).
1.Starting test and creeping test 2.Measuring the different constant meters synchronously. 3.With the protect function of overload, short voltage circuit and open current circuit. 4.The testing software with friendly windows 2000 and xp interface, include functional module of all kinds of modern energy meter needed, to reality error test, harmonic test, demand test, influence test. 5.The stored testing data can be transferred to multi-format for other program using
Snt 1100 single phase meter test bench is widely used in power utilities,¡émeter manufacturer,¡émeasurement/quality test lab and other enterprises to test single phase energy meter.
Ac current output (0~10/20a) Adjust fineness: 0.01%rg Accuracy: better than ¡¨¤0.05%rg Stability: better than ¡¨¤0.01%rg/1min Distortion degree: better than 0.1% (not capacitive load) Output power: 25va Full load adjust rate: less than ¡¨¤0.01%rg Full load adjust time: less than 1ms Stability time: ¡¨¤60ppm/ year Power output: Accuracy: better than 0.05%rg Stability degree: better than 0.01%/1min Phase position: Adjust range: 0¡«359.99 degree Differentiation: 0.01 degree Accuracy: ¡¨¤0.03 degree Frequency: Adjust range: 40hz¡«65hz Differentiation: 0.002hz Accuracy: ¡¨¤0.002hz Temperature float: ¡¨¤0.5ppm/¡æ Stability time: ¡¨¤4ppm/year Power factor: Adjust range: -1¡«0¡«+1 Differentiation: 0.0001 Accuracy: 0.0005 Harmonic output: The instrument can accurately output 2¡«22 harmonics. Dimension& weight: Dimension¡êo450mm¡¨¢380mm¡¨¢160mm¡ê¡§l¡¨¢w¡¨¢h¡ê© Weight¡êo¡¨¹18kg¡¡ê Environment condition: Working temperature¡êo0¡æ¡«40¡æ Relative humidity: ¡¨¹85% Storage condition: ¡ê-30¡æ¡«60¡æ
Measure normal parameter of power line: Vrms, irms, frequency Active power, reactive power, apparent power Phase angle between voltage and current Power factor Calibrate single phase meter; Measure harmonic of voltage and current; Measure waveform of voltage and current; Measure current transformer¡¡¥s ratio (option); Energy accumulation test; Built-in clock, record testing time exactly; Store, check and transmit the measured data; Connected to pc, reading recorded data and real-time measured data by pc; Alarm when the tested voltage and current over the testing range; Connected to portable printer (option).
Frequency 50hz ¡¨¤2hz Outside magnetic field intensity: ¡¨¹0.025mt Warm-up: the time of warm-up: ¡y30 minutes Using condition: Environment temperature: 5¡æ¡-40¡æ Relative humidity 25%¡«85% Test current: 0.05a¡«120a Current range 1a, 10a, 100a Imax=120a Test voltage 50v¡-480v Voltage range: 50v, 100v, 200v, 400v Umax=480v Accuracy: Current: ¡¨¤0.05%rg 0.125¡«120a Voltage: ¡¨¤0.05%rg 40v¡«480v Power: Active power ¡¨¤0.05% (50v¡«480v, 0.2a¡«120a, cosØ¡y0.5) Reactive power ¡¨¤0.1% (50v¡«480v, 0.2a¡«120a) Apparent power ¡¨¤0.1% (50v¡«480v, 0.2a¡«120a) Power factor Measurement range: 0¡«¡¨¤1 Accuracy: ¡¨¤0.05%rg (cosØ¡y0.5) Phase: Measurement range: 0¡ã¡«360¡ã Accuracy: 0.05¡ã(50hz) Frequency: 0.03%rd (45hz¡«65hz) Pulse output: Ttl level Load ¡ê¾2kw High frequency output port: fh Low frequency output port: fl Affection of temperature: (5¡æ¡«40¡æ) Voltage, current and frequency: ¡¨¹¡¨¤15ppm/¡æ Power: ¡¨¹¡¨¤30ppm/¡æ Communication port: Rs232 Rs485 Power supply: Voltage: ac220v¡¨¤22v Frequency: 50hz¡¨¤2hz Power: 40va Dimension: 432mm¡¨¢131mm¡¨¢308mm Weight: 15kg
To determine the stability of electric appliances which are used on a table or on the floor In accordance with iec 60065 / 1998-07 clause 19.1, iec 60335-1 / 1991-04 clause 20.1, iec 60601-1 /1988 clause 24.1, iec 60950 / 1991 + amendments, modified, clause 4.1.1, en 60335-1 / 1994 and a11 / 1995 clause 20.1, en 60950 / 1992 + amendments up to 1997 clause 4.1.1, vde 0700 part 1 / 10.95 clause 20.1 and part 3 / 3.96 clause 20.1, vde 0730 part 1 / 3.72 clause 20a, vde 0805 / 11.97 clause 4.1.1 Packed with strong wooden case
Description Te261 visual fault locator is visible red laser source for finding breaks and tight bends in optical fibers. Te261 generates red laser and the visible red laser that escaping from optical fibers makes testing and finding breaks in lans, verifying continuity, checking the validity of patch cables or looking for cracked fiber in splice cases, bad connectors, and tight bends in fiber cable. Paper carton, 0.5kg
Digital fusion splicer with automatic focus function Fiber core can be display clearly Single x or y view and x & y view simultaneously Auto detect cleaved end face fault Display fiber cleaved and offset angle Display core and clad offset 5.6 inch tft color lcd monitor with clear digital image display Usb & vga interface Software upgrade via usb interface Paper carton, weight is 12kg
Core to core alignment by pas technology (pas:profile alignment system) Fiber core can be display clearly Single x or y view and x & y view simultaneously Auto check quality of cleaved end face 5.7 inch tft color lcd monitor with clear digital image display Usb & vga interface Software upgrade via usb interface Paper carton, weight is 12kg
Features: Small, powerful and portable Battery powered 3.5 inch tft-lcd can meet the needs of high luminance environment and night. Be with simple and friendly graphical user interface. Touch screen panel and keyboard button can meet different operator's habits. Hotkey for rapid testing, and just press the hotkey you can obtain the required operational test results. Provides three power saving modes, close the lcd screen, equipment sleep and power-down, continuous working time up to 8 hours 1310/1550 dual-wavelength testing Visible light source, facilitate to inspect fiber break Complete pc analysis software Easy to operate Application: Determine fiber optic cable or fiber optic's failure point, connection point, breakpoint position. Describe fiber optic cable or fiber's loss distribution curve, measure cable, fiber's length and the loss, attenuation coefficient between two points Measure fiber optic cable, optical fiber connector's insertion loss Measure fiber optic cable, optical fiber's reflection loss Be widely used in metropolitan, wan, catv and other communication systems for fiber optic cable or fiber installation, troubleshoot, transformation and maintenance. Paper carton, weight is 5 kg
Battery power display Application: 1. Maintenance telecom 2. Maintenance catv 3. Test lab of fiber optic 4. Optical fiber sensors Paper carton
Tfr is innovative product of taurus designed to measure impedance along with resistance of transmission line t is Salient features: Ø the equipment operates at 25 khz which and virtually isolates the parallel transmission Tower earth path without physical isolation of over head earth wire by use of this high frequency and neutralizing circuits. Ø reliable, steady, repeatable readings in induced environment Ø constant current output (20ma) from a high voltage source (250v) to override the noise in the induced environment. Ø the taurus preziohm tfr is designed to be immune to power frequency and its harmonics Ø dynamic measurement. Ø housed in ip67 pelican casing. Packaging as per international standards
200 tones in different models. Portable models are very convenient and useful for site use where carrying frequently the specimens for testing in a standard laboratory is inconvenient and uneconomical. With special attachments, the machines can also be used for bricks, hallow or solid concrete blocks, using appropriate capacity machine. In general compression testing machine consists of a load frame with suitable platens and a pumping unit with pressure gauge, either hand operated or electrically-cum-hand operated. Load frame and pumping unit are connected by pressure pipes. Wooden packing
Foremost in quality of workmanship and investment in “state of art” technology to manufacture world class LT switchboards, we have established ourselves as a symbol of quality and innovation in this field. The Panels have been successfully tested at CPRI to withstand short circuit levels of 50KA for 1 sec, IP 54 degree of protection & Temperature rise as per international standards. The Design and Engineering department is well equipped with Computer Aided Design (CAD) systems and drafting facilities for accurate and quick preparation of design & execution.