To determine the stability of electric appliances which are used on a table or on the floor In accordance with iec 60065 / 1998-07 clause 19.1, iec 60335-1 / 1991-04 clause 20.1, iec 60601-1 /1988 clause 24.1, iec 60950 / 1991 + amendments, modified, clause 4.1.1, en 60335-1 / 1994 and a11 / 1995 clause 20.1, en 60950 / 1992 + amendments up to 1997 clause 4.1.1, vde 0700 part 1 / 10.95 clause 20.1 and part 3 / 3.96 clause 20.1, vde 0730 part 1 / 3.72 clause 20a, vde 0805 / 11.97 clause 4.1.1 Packed with strong wooden case
1. Size of concrete specimens for compression strength test Concrete cubic specimen: 150X150X150mm, 100X100X100mm, 200X200X200mm Cylindrical concrete specimen: diameter 150X300mm, diameter 100X200mm, diameter 200X400mm 2. Brief introduction of concrete compressive strength test procedure 1) Placing the concrete specimen---place the test specimen on the lower bearing block. Carefully align the axis of the specimen with the center of thrust of the spherically seated block. 2) Apply the load continuously and without shock until the specimen fails and record the maximum load carried by the concrete specimen during the test. Note the type of failure and the appearance of the concrete. 3.Relative test method GB/T 50081 standard for test method of mechanical properties on ordinary concrete ASTM C39 standard test method for compressive strength of cylindrical concrete ASTM E74 practice of calibration of force-measuring instruments for verifying the force indication of testing machine 4. Specifications for concrete compressive strength testing machine Max. capacity: 3000KN( lower or higher capacity can make to order) Grade of testing machine: grade 1 Distance between upper and lower compression platen: 320mm Stroke of piston:50mm Size of upper and lower compression platen:375X375mm Weight :about 900kg
Overview: The RT6103B Multi-function single phase energy meter test instrument adopts internationally advanced new-generation digital power source technology, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The Multi-function single phase energy meter test instrument comprises of PWM power source, standard digital energy meter, error processor and PC processing software, this energy meter test instrument can test 3 to 60 various watt-hour meters of Grade 0.5 or lower simultaneously, also is an ideal new-generation multi-position energy meter testing instrument. Technical Parameters: 1. Accuracy class: 0.1/0.05 2. Reference standard energy meter£ºSingle phase wide-measurement range standard energy meter(Accuracy class:0.1/0.05), Multi-path voltage transformer: Accuracy class:0.01;Rated load per path:10VA. 3. Voltage range:220v(240V option),Output range:0~125%,Resolution:0.01%full range. 4. Current measurement range:0.1~100A(200A option),Output range:0~120%,Resolution:0.0001A(minimum). 5. Phase angle:0~360¡ã,Resolution of phase angle setting:0.01¡ã. 6. Frequency:45Hz~65Hz,Resolution:0.01Hz. 7. Output waveform distortion: Both voltage and current
Overview: The RT6303-S Three Phase Energy Meter Test Instrument(Split Type) adopts internationally advanced new-generation digital power source technologt,integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way.The Three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis,digital frequency modulation,digital amplitude modulation,digital phase-shifting,pulse width modulation and so on to bring you such important features as high reliability and good load characteristics.Its more humane and intelligent meter calibration software makes it possible for an ordinary,heavy and boring calibration to be carried out more easily and efficiently. Technical Parameters: 1. Accuracy class: 0.1/0.05 2. Reference standard energy meter: Three phase wide-measurement range standard energy meter,Accuracy class:0.1/0.05 3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range,adjustable phase by phase 4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase 5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase 6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz 7. Output waveform distortion:Both voltage and current
Optional accessories Cable port: two size of cable port is available: diameter: 50mm, diameter:100mm. Double door Pass room: provided to avoid disturbance of atmospheric temperature and humidity while opening the door. Floor reinforcement: can be fixed if heavy specimen placed in the chamber for test. Carry-in inclined platform: provided below the door to facilitate moving of specimens in and out through the door. normal running, a malfunction running or stand by occurs. Water purifier
We have been in this line for many years, our products is very competitive and resonable . Wooden cases, 100kg, 620x460x1530
We are offering eut monitoring system that includes eut monitoring, analysis and data recording. These eut monitoring systems analyzes data during the test for interference or failure conditions, and records test data for retrieval after the test is complete. It is designed as a stand-alone system to communicate with the main test system using our eut monitoring and test software. The eut (equipment under test) monitoring system combines the following: Monitoring instrumentation Video and audio equipment Software to provide eut signal monitoring (analog and digital) Eut stimulation Monitoring for visual or audio interference during testing The monitoring is enabled only after the test level is established with the main test system, since the EUT Monitoring System is fully synchronized with test system. These are appreciated because all parameters captured by the EUT Monitoring System during testing ensures to accurately recreate interference or failure points to resolve compatibility issues monitored. These systems are configured specifically to cater the test needs and can be configured for specialized requirements such as audio breakthrough required by mobile radio standards and ABS/TCS testing needed in automotive test standards. Our entire range of standard as well as customized seamless interface with main test system completes the control of the EUT Monitoring System from the control room console. System Components: EUT stimulation and monitoring instruments selected to cover applicable specifications and meet your price/performance requirements Video monitoring system using shielded color cameras to visually monitor equipment under test An audio monitoring system can supply as a stand-alone solution or built into the video camera system A system controller with application software that offers power to control monitoring equipment These are used to process and store data, graphics, and results of series measurements System cabling and switching to connect the control room with the chamber Shielded room allow test engineers complete control of the EUT monitoring system from the desktop Fiber optic links for analog and digital signal monitoring. We are offering Radiated Conducted EMS that is used for EMS Testing Many electronic products. The subassemblies must meet immunity testing requirements depending on the product's target marketplace. These are designed specifically to meet the requirements of specific environmental use and internal manufacturer's requirements. It also needs an engineer to control instrumentation from a variety of vendors and perform detailed test procedures for numerous specifications. These are known for integrating test instrumentation, system controls, positioning devices, and software to perform automated, semi-automated, and manual immunity measurements in an anechoic chamber, shielded room, or test cell. The range of test specifications is carefully evaluated to develop an integrated test environment covering the basic, generic, product family and product specific standards. The entire recommendation is based on proven system installations, in-house research and development, and extensive experience with dozens of test instrument suppliers. It result in a seamless interface the test system and the test environment. We are offering a range of Radiated Conducted EMI that is designed and manufactured to use in an anechoic chamber, shielded room, OATS, or test cell to perform automated, semi-automated, and manual emissions measurements. These systems are integrated with test instrumentation, system controls, positioning devices and software. This helps to test specific products or subsystems for electromagnetic emissions according to international, R&D and manufacturer-specific standards. Designed especially to meet customerÆs requirements, these receive the exact system solution. This is offered without unnecessary components and costs associated with off-the-shelf, "one size fits all" test systems. Further, we also offer turnkey solution for our Radiated Conducted EMI, which includes system designing and installation with dozens of test instrument supplies. The turnkey EMI Test System designed by us assist to meet product testing requirements. A typical system includes: EMI test instrumentation selected to cover applicable frequencies and meet your price/performance requirements. Antennas/LISNs/Clamps selected to match both test standards and test facility capabilities. Measurement Accessories such as switching and positioning devices that simplify control and increase efficiency. An EMI Main Control Console with instruments and system controls strategically placed to provide test engineers easy access to all functions, and a comfortable, ergonomically-correct work environment. A System Controller with Application Software that offers state-of-the-art power to perform emissions tests from pre-scan to final measurements and to control multiple EMI analyzers and receivers. Proven Solutions: Our test system developments are based on the systems in Europe, North America, and Asia. Each new system incorporates the latest technologies instead of an off-the-shelf approach to design and to explicitly cover the standards. It provides accurate, repeatable measurements and minimizes demands on your limited resources. We are offering Observation System that is appreciated by the clients for conforming to various international quality standards. These are known as Specific Absorption Rate Test Systems (SRC), which include SAR Measurements, System Components, Measurement System, Probes & Measurement Accessories and Position Controller & Positioning Robot. The detail description of Specific Absorption Rate Test Systems is as follows: The SAR System: It is used to measure electromagnetic fields and calculated SAR over a customer-specified frequency range. All tests are conducted in a shielded test room. SAR Measurements: SAR testing works with the thermal effects of human exposure to RF electromagnetic fields. It corresponds to the relative amount of RF energy absorbed of a device close to the body. The test is conducted to verify that the RF energy emitted by a device is within permissible limits for public exposure as defined by test standards. The SAR Measurement System is comprised of the following subsystems: Measurement System: It is an easy to use, flexible package optimized for dosimetric evaluation of radio products. The whole package includes Data Acquisition Electronics and system control computer. Probes and Measurement Accessories: Various broadband probes and support accessories are available based on test requirements. It includes probes to measure current distribution on radio products in free space, to measure fields inside fluids simulating body tissue and to test radiated emissions from mobile radio equipment. Position Controller and Positioning Robot: The automated robot positions the probe inside the tissue-simulating liquid over a precisely defined volume. The robot is controlled by a multiprocessor positioning device. Air tieght packing with container, steel packing, wooden packing
Description Te261 visual fault locator is visible red laser source for finding breaks and tight bends in optical fibers. Te261 generates red laser and the visible red laser that escaping from optical fibers makes testing and finding breaks in lans, verifying continuity, checking the validity of patch cables or looking for cracked fiber in splice cases, bad connectors, and tight bends in fiber cable. Paper carton, 0.5kg
Overview: The RT6103-S Single Phase Energy Meter Test Instrument (Split Type) adopts internationally advanced new-generation digital power source technologt, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The single phase energy meter test instrument comprises of PWM power source, standard digital energy meter,error processor and PC processing software, this energy meter test instrument can test 3 to 60 various watt-hour meters of Grade 0.5 or lower simultaneously, also is an ideal new-generation multi-position energy meter testing instrument. Technical Parameters: 1. Accuracy class: 0.1/0.05. 2. Reference standard energy meter£ºSingle phase wide-measurement range standard energy meter.(Accuracy class:0.1/0.05). Multi-path voltage transformer: Accuracy class:0.01; Rated load per path:10VA. 3. Voltage range:220v(240V option),Output range:0~125%,Resolution:0.01%full range. 4. Current measurement range:0.1~100A(200A option),Output range:0~120%,Resolution:0.0001A(minimum) 5. Phase angle:0~360¡ã,Resolution of phase angle setting:0.01¡ã. 6. Frequency:45Hz~65Hz,Resolution:0.01Hz. 7. Output waveform distortion:Both voltage and current