Features This instrument is compatible with four standards of site to measure surface roughness of various machinery-processed parts, calculate corresponding and clearly display all measurement parameters. When measuring the roughness of a surface, the sensor is placed on the surface and then uniformly slides along the surface by driving the mechanism by the sharp built-in probe. This roughness causes displacement of the probe which results in change of inductive amount of induction coils so as to generate Specifications Display·ª 4 digits, 10 mm LCD, with blue backlight Parameters: Ra, Rz, Rq, Rt Measuring Range Ra, Rq: 0.005-16.00um/0.020-629.9uinch Rz,Rt: 0.020-160.0um/0.078-6299uinch Accuracy: f_f+10% Fluctuation of display value: Not more than 6% Sensor : Test Principle: Inductance type Radius of Probe Pin: 5um Material of Probe Pin: Diamond Dynamo-measurement of Probe: 4mN(0.4gf) Probe Angle: 90fp Vertical Radius of Guiding Head: 48mm Maximum driving stroke: 17.5mm/0.7inch Cutoff length (l): 0.25mm / 0.8mm / 2.5mm optional Evaluation length: 5l Driving speed: sampling length = 0.25mm Vt=0.135mm/s sampling length = 0.8mm Vt=0.5mm/s sampling length = 2.5mm Vt=1mm/s returning Vt=1mm/s Profile digital filter Filtered Profile: RC Filtered Profile: PC-RC Filtered Profile: Gauss Non-Filtered Profile: D-P Resolution : .001¬ªm if reading ·+10¬ªm 0.01¬ªm if 10¬ªmf_reading·+100¬ªm 0.1¬ªm if reading fª100¬ªm Evaluation length : 5 cut-off Power Li-ion battery: rechargeable Operating conditions: Temp. 0~50f¦ Humidity