Technical index
1)Crack width measurement range08mm
2)Measurement accuracy0.01mm
3)Large storage capacityThe image and width data can be stored in 100 thousand crack measuring points
4)Built in rechargeable lithium battery,can work continuously for 8 hours
5)Working temperature-10+50
6)Host volume85mm*168mm*208mm
7)Weight960g
Technical index 1)Crack depth test range650 mm 2)Test error10 3)Test data storage6000 sets of test data 4)Host volume 190mm*183mm*84mm 5)Battery6 section 5 alkaline battery,power supply time more than 10 hours 6)LCD screen resolution160*128 lattice 7)Host volume190mm*183mm*84mm
Technical index 1)Crack depth test range650 mmTest error10 2)Crack width measurement range08mmWidth measurement accuracy0.01mm 3)Crack depth test data storage6000 sets of test dataAnd can store 100 thousand crack measuring points of the image and width data 4)LCD screen resolution160*128 lattice 5)Built in rechargeable lithium battery, can work continuously for 8 hours; 6)Working temperature-10+50 7)Host volume190mm*183mm*84mm
1. Follow the specifications: ASTM D5882 Standard Test Method for Low Strain Integrity Testing of Piles JGJ106-2003 (China) Technical code for testing of building foundation piles 2. Parameters:: 1). Size: 62 * 172 * 225 mm. 2). Weight: 2.0 kg. 3). High-contrast touch screen display. 4). Temperature range: Operating Range: 0° to 40° C; Storage Range: -20° to 65° C. 5). Powered by internal battery (6 hours duration). 3. Functional: 1). The LPT-E is used for Integrity pile testing and judging defect position 2). Automatic data storage 3). Signal amplification capability 4). Data can be averaged over a variable number of blows. 5). Variable signal amplification over time 6). 24-bit A/D converter 7). Sample size: 4k 8). Sample Frequency: 48kHz, 96 kHz,144 kHz
1. Follow the specifications: ASTM D4945 Standard Test Method for High-Strain Dynamic Testing of Piles JGJ106-2003 (China) Technical code for testing of building foundation piles 2. Physical (1) Size: 62 *172 * 225 mm (2) Weight: 1.7 kg (3) 8 inch and high brightness color LCD touch screen (4) Temperature range: Operating: 0° to 40° C; Storage: -20° to 65° C (5) The cables and connectors are suitable for PDA 3. Technical (1) HPT used for determining the pile bearing capacity and pile integrity. (2) It can be used for pile driving monitoring and the cast-in-place pile test. (3) Sampling frequency is Optional of 10 kHz, 20 kHz, 30 kHz and 40 kHz. (4) Sampling points are optional of 1024, 2048 and 4096. Maximum sampling time is up to 400 ms (5) Before test the two accelerometers and two strain transducers are self-checked automatically, determine whether the system is in normal state. (6) Automatically check the static strain deviation of the strain transducer during installation and adjusted to zero before blow. (7) Test data exported through the external u-disk (8) During test every blow can be saved automatically (9) Storage capacity of more than ten thousands blows. (10) HPT can be used for pile driving monitoring and the cast-in-place pile (11) HPT data can save as *.X01(used for PDA-W) (12) The main cable and connecting cable are compatible with the PDA. (13) Built-in lithium battery can be used more than 5 hours continuously. (14) PDAR program carry on CASE method analysis. (15) RCAPWAP program carry on match analysis automatically or manually.
1. Follow the specifications: ASTM D5882 Standard Test Method for Low Strain Integrity Testing of Piles JGJ106-2003 (China) Technical code for testing of building foundation piles 2. Parameters:: 1). Size: 62 * 172 * 225 mm. 2). Weight: 2.0 kg. 3). High-contrast touch screen display. 4). Temperature range: Operating Range: 0° to 40° C; Storage Range: -20° to 65° C. 5). Powered by internal battery (6 hours duration). 3. Functional: 1). The LPT-E is used for Integrity pile testing and judging defect position 2). Automatic data storage 3). Signal amplification capability 4). Data can be averaged over a variable number of blows. 5). Variable signal amplification over time 6). 24-bit A/D converter 7). Sample size: 4k 8). Sample Frequency: 48kHz, 96 kHz,144 kHz
1. Follow the specifications: ASTM D4945 Standard Test Method for High-Strain Dynamic Testing of Piles JGJ106-2003 (China) Technical code for testing of building foundation piles 2. Physical (1) Size: 62 *172 * 225 mm (2) Weight: 1.7 kg (3) 8 inch and high brightness color LCD touch screen (4) Temperature range: Operating: 0° to 40° C; Storage: -20° to 65° C (5) The cables and connectors are suitable for PDA 3. Technical (1) HPT used for determining the pile bearing capacity and pile integrity. (2) It can be used for pile driving monitoring and the cast-in-place pile test. (3) Sampling frequency is Optional of 10 kHz, 20 kHz, 30 kHz and 40 kHz. (4) Sampling points are optional of 1024, 2048 and 4096. Maximum sampling time is up to 400 ms (5) Before test the two accelerometers and two strain transducers are self-checked automatically, determine whether the system is in normal state. (6) Automatically check the static strain deviation of the strain transducer during installation and adjusted to zero before blow. (7) Test data exported through the external u-disk (8) During test every blow can be saved automatically (9) Storage capacity of more than ten thousands blows. (10) HPT can be used for pile driving monitoring and the cast-in-place pile (11) HPT data can save as *.X01(used for PDA-W) (12) The main cable and connecting cable are compatible with the PDA. (13) Built-in lithium battery can be used more than 5 hours continuously. (14) PDAR program carry on CASE method analysis. (15) RCAPWAP program carry on match analysis automatically or manually.
Purpose SYR51+ rebar Location system is used to test rebar diameter, distribution, coating thickness in concrete. Specification JGJ/T152-2008 Performance Longer service life of the Connector Clip: The instrument has long service life because of using Lemo Connector Clip which comes from Swiss and uses for aircraft industry. Good quality of signal cable: The signal cable has long service life because of its flexible and substance. High precision and stability: The instrument can locate the steel-bar accurately and quickly. Longer service life of the sensor: Improve the service life by paste abrasion resistance allowance bottom of the sensor Single sensor: No-change sensor in test, switching between high and low test range can assure the precision of test data and the test depth. Display test information real-time: Display the test data directly to avoid man-made errors. Grid and section scan mode: Instrument can display steel bar distribution and scan steel bar without concrete boundary limited. Three-wheel steel-bar scan system: The system can assure scan path along line and the precision of test data. Powerful Windows data process and analysis software: Software can display analysis result by diagram. Test data can be export to word or Excel easily.
Purpose The instrument is used to test the degree of steel-bar corrosion in electrochemical method. Specification GB50204-2002 Performance 1. Two test mode. The potentiometry and gradient method is used to test steel-bar corrosion which fit for different working field. 2. Permanent reference electrode. Saturated CuSO4 solution is sealed up completely in reference electrode. Field test keeps clean, simple and pollution-free operations. 3. Automatic measure environmental temperature. Instrument design to contain a measure environmental temperature module, it can measure, record and display environmental temperature quickly no thermometers required. 4. Can save test date. Convenient for laborer data management. 5. Display test result intuitively. Display test result used icon mode, The icon color is more dark, the steel-bar corrosion is more serious. User can observe the corrosion degree intuitively. 6. Real USB transmission. Data can be transmitted to computer for future process and analysis. 7. Powerful data process and analysis software in windows. Software can display analysis result by spectrum and isoline. Test data can be export to word or excel easily. Performance 1. Test range: +/-2000 mV 2. Testing accuracy: +/-1 mV 3. Test point distance: 1~ 99cm setting 4. Applicable environmental: Temperature: -10? ~ +40? Dampness:
Supplier: Concrete testing equipment, chloride tester, alkali tester, concrete ion penetration tester, strength tester, test hammer, rebar locator, thickness tester, crack width tester, ndt equipment, pile testing equipment, high strain dynamic pile tester, low strain dynamic pile tester, static loading tester