Standard:
Conforms to VDE 0636-1-4,DIN 43 620-1-4,IEC 60269 and EN 60269,RoHS
Certifications:
China Compulsory Product Certification(CCC)
Compulsory Product Certification of EU(CE)
Characteristics:
High breaking capacity,the highest is 120KA
500/690Vac/250Vdc/440Vdc
Operating Frequency:45-62HZ
Dual Indication
Low power losses
Standard: Conforms to VDE 0636-1-4,DIN 43 620-1-4,IEC 60269 and EN 60269,RoHS Certifications: China Compulsory Product Certification(CCC) Compulsory Product Certification of EU(CE) Characteristics: High breaking capacity,the highest is 120KA 500/690Vac/250Vdc/440Vdc Operating Frequency:45-62HZ Dual Indication Low power losses
Standard: Conforms to VDE 0636-1-4,DIN 43 620-1-4,IEC 60269 and EN 60269,RoHS Certifications: China Compulsory Product Certification(CCC) Compulsory Product Certification of EU(CE) Characteristics: High breaking capacity,the highest is 120KA 500/690Vac/250Vdc/440Vdc Operating Frequency:45-62HZ Operating Class:a/R Dual Indication Low power losses
Standard: Conforms to VDE 0636-1-4,DIN 43 620-1-4,IEC 60269 and EN 60269,RoHS Certifications: China Compulsory Product Certification(CCC) Compulsory Product Certification of EU(CE) Characteristics: High breaking capacity,the highest is 120KA 500/690Vac/250Vdc/440Vdc Operating Frequency:45-62HZ Operating Class:a/R Dual Indication Low power losses
The Variable Speed Drive FRENIC series is equipped with functions and performance to meet all types of requirements, and in addition it is easily maintained and environmentally friendly. The series lineup ranges from simple to advanced-function models, enabling model choices matching situations for use. Fuji Electric provide Variable Speed Drives perfect for automating and with energy saving devices like a fan pump or carrier and variable speeds.
KTK fast-acting 13/32" x 1-1/2"supplemental fuse Fast-acting supplemental fuse. Black color code (600 Vac max). For superior protection, Eaton recommends upgrading to Bussmann series Low-Peak Class CC fuses. Agency information â?¢ UL Listed, Std. 248-14, Guide JDYX, File E19180, CSA Certified, C22.2 No. 248.14, Class 1422-01, File 53787, HRC-MISC, RoHS compliant, CE Features â?¢ Black color code for 600 Vac rating â?¢ Fast-acting for resistive loads â?¢ Melamine tube construction with nickel-plated bronze endcaps Typical applications â?¢ Control circuits â?¢ Lighting circuit protection â?¢ Meter circuits KTK-1/10 KTK-1/8 KTK-2/10 KTK-1/4 KTK-3/10 KTK-4/10 KTK-1/2 KTK-6/10 KTK-3/4 KTK-1 KTK-1-1/4 KTK-1-1/2 KTK-2 KTK-2-1/2 KTK-3 KTK-3-1/2 KTK-4 KTK-5 KTK-6 KTK-7 KTK-7-1/2 KTK-8 KTK-9 KTK-10 KTK-12 KTK-15 KTK-20 KTK-25 KTK-30
FNQ-R Class CC Limitronâ?¢ time-delay, rejection-type fuse Time-delay, branch circuit, rejection-type fuse. For superior electrical protection, Eaton recommends upgrading FNQ-R fuse applications to Bussmann series Low-Peak LP-CC fuses, see page 1-5. For dimensions. Ratings Volts 600 Vac (or less) 300 Vdc (15-20 A) 32 Vdc (self certified) Amps 1/4-30 A IR 200 kA RMS Sym. 20 kA DC (15 and 20 A only) Agency information UL Listed, Std 248-4, Class CC, Guide JDDZ, File E4273, CSA Certified, Class 1422-01, File 53787, RoHS compliant, CE Features Class CC rejection feature, with appropriate fuse block, prevents inserting lesser-rated supplementary fuses Time-delay compatible with inrush characteristic of small control transformers Current limitation at Class CC levels provides maximum component short-circuit current rating protection 200 kA interrupting rating provides high ratings for control circuit locations Typical applications Line protection, small control transformers Industrial controls and panels Isolated, in-line fuse holders FNQ-R-1/4 FNQ-R-3/10 FNQ-R-4/10 FNQ-R-1/2 FNQ-R-6/10 FNQ-R-3/4 FNQ-R-8/10 FNQ-R-1 FNQ-R-1-1/8 FNQ-R-1-1/4 FNQ-R-1-3/10 FNQ-R-1-4/10 FNQ-R-1-1/2 FNQ-R-1-6/10 FNQ-R-1-8/10 FNQ-R-2 FNQ-R-2-1/4 FNQ-R-2-1/2 FNQ-R-2-8/10 FNQ-R-3 FNQ-R-3-2/10 FNQ-R-3-1/2 FNQ-R-4 FNQ-R-4-1/2 FNQ-R-5 FNQ-R-5-6/10 FNQ-R-6 FNQ-R-6-1/4 FNQ-R-7 FNQ-R-7-1/2 FNQ-R-8 FNQ-R-9 FNQ-R-10 FNQ-R-12 FNQ-R-15 FNQ-R-17-1/2 FNQ-R-20 FNQ-R-25 FNQ-R-30
Cube Meat Cutting Machine for whole pcs coat /sheep or other poultry cube meat with bone or no-bone cutting machine ,good quality ,low cost .welcome order! Paramters: Capacity 600kg/hour . Machine size : 1300 * 600 *950mm. Machine weight :200kg Voltage 220V/3kw or 380V/1.5kw Warranty time 2 years ,offer whole-life after-sale serive . There are wheels below that can move back and forth, When client after working can direct water -washing this machine ,for raw material are all stainless steel . Easy Clean And Maintain/Durable And Able To Withstand Heavy Use./Â Easy To Operate And Control/Slice Meat To A Consistent Thickness all satisfied .
1. Use (H) RW 12-27 drop fuse and pull-load drop fuse are outdoor high-voltage protective appliances, which are assembled on the high-voltage side of distribution transformer or branch lines of distribution line, and are used for overload and short-circuit protection of transmission lines and power transformers and for sharing rated load current. 2. Brief introduction of structure The drop fuse consists of two parts: insulating bracket and fuse pipe. The static contacts are installed at both ends of the insulating bracket, and the movable contacts are installed at both ends of the fuse pipe. The fuse pipe consists of an inner arc extinguishing tube and an outer epoxy glass tube. Pull-load drop fuse adds elastic auxiliary head and arc extinguishing cover to divide and close load current. When a drop fuse is in normal operation, the fuse pipe is tensioned by means of the fuse. Then a closed position is formed. When the system fails, the fault current causes the fuse to fuse rapidly and form an arc. The arc extinguishing tube is heated by the arc and decomposes a large number of gases, which forms a high pressure in the tube and blows longitudinally along the pipeline. The arc is rapidly elongated and extinguished. After the fuse is fused, the lower moving contact loses tension and turns down. The locking mechanism releases the fuse tube, and the fuse tube falls down, forming an obvious breaking position. When the load needs to be pulled, the contact is pulled by the insulating rod. At this time, the active and static contacts are still in contact. The contacts are pulled by the insulating rod, and the auxiliary contacts are separated. Arc is generated between the auxiliary contacts. The arc is elongated in the slot of the arc extinguishing hood. At the same time, the arc is extinguished when the current passes zero. 3. Implementation criteria The product performance conforms to GB15166.3-94 national standard and IEC282-2 international standard. 4. Conditions of Use 1. Environmental temperature: - 40 ~40 C; 2. No more than 1200 m above sea level; 3. The wind speed is not more than 35m/s. 4. Earthquake intensity does not exceed 8 degrees. 5. Fuses are not suitable for the following places: A. Places where there is a danger of combustion or explosion; B. Places with violent vibration or shock; C. Areas with heteroelectrochemical gases, severe air pollution and salt fog. 5. Instructions for Order 1. Product type, name, rated voltage, rated current and rated switching-on current; 2. Environmental requirements (anti-pollution, plateau type); 3. Special requirements can be consulted with our company. Manufacturer of intelligent switch cabinet--low-voltage, high voltage power distribution switch cabinet, also have many other electric equipment electric power accessories, intelligent transmission and distribution automation system