ZBW Type Prefabricated Substation
ZBW packaged substation, also known as prefabricated substation. It meet GB17467-1998 high and low voltage prefabricated substation and IEC1330 standards etc. As a new type of power supply and distribution device, has more advantages than traditional civil substation.
Product Description
ZBW packaged substation, also known as prefabricated substation. It meet GB17467-1998 high and low voltage prefabricated substation and IEC1330 standards etc. As a new type of power supply and distribution device, has more advantages than traditional civil substation. Such as smaller size, smaller floor area, compact structure, flexible movement, which greatly reduce period and area for construction in site, also the construction cost. Meanwhile, prefabricated substation is easy to be installed at site , can realize rapid power supply, almost maintenance free. Most particularly, it is placed at load center so that reduce power loss effectively to improve power quality, enhance the reliability of power supply and also is significant for distribution network transformation.
This substation fulfills the functions such as transformation of energy, distribution, transmission, metering, compensation, system control, protection and communication.

The ZBW prefabricated substation is composed by the high-voltage switchgear, low-voltage distribution panel, distribution transformer and enclosure. The high-voltage switchgear adopts air load switch and the transformer is dry-type or oil immersed type. The substation adopts good ventilation structure with elegant appearance and good heat-insulating performance. The temperature rise of the compartments caused by the outdoor solar radiation can be reduced to within the lowest limits on account of the upper and lower ventilation windows. The forced ventilation device and the temperature auto-controlled device should be installed in the substation. The systems of control, protection, live display and the lighting are equipped in each separate unit.
Product Features

Price and Minimum Quantity

Price: Negotiable
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Zbw Type Prefabricated Substation

GOLD Member
May-08-25
Buyer From Dhaka, Dhaka, Bangladesh
Apr-18-20
 
Functional characteristics
1. The whole box body is divided into four parts: the bottom floor, the frame, the top frame and the box cover. The frame and the top frame are assembled by steel structural parts. The outer shell can be made of coloured steel plate which conforms to the heat insulation plate or steel plate. The clapboard is made of coloured steel composite plate to prevent thermal radiation and thermal guidance between different types. The exposed structural parts are treated by strict acid washing, phosphating, spraying and other processes to ensure corrosion resistance, moisture and heat resistance, mildew resistance and strong outdoor weather resistance.
2. The sub-box structure is adopted to avoid oil pollution in transformer tank.
3. Adopt new louver structure, large area of heat dissipation and ventilation, suitable for areas with strong wind. V-shaped structure design can effectively prevent rainwater from entering while enhancing ventilation.
4. Low-voltage main switch adopts circuit breakers from well-known manufacturers at home and abroad.
5. The transformer uses S11-M series fully sealed oil-immersed power transformer, which has the advantages of low loss, low noise and high efficiency. It can achieve good energy-saving effect and reduce pollution.
6. Substation has perfect protection performance, convenient operation, high and low voltage metering is optional, and can be equipped with automatic reactive power compensation device according to user's requirements.
Jun-18-18
 
American prefabricated substations is based on urban and rural power grid construction and development and transformation of the needs of the development of a series of products. It is the transformer body, switchgear, fuses, tap-changers, low-voltage power distribution equipment and other auxiliary equipment for the combination of transformer, to meet the user energy metering, reactive power compensation, low voltage shunt and other preparation requirements. ZGS-type modular transformer as AC 50Hz, 6 ~ 10kV network, rated capacity of 63 ~ 1600kVA independent set of power distribution equipment, both for outdoor use, can also be used indoors. Widely used in industrial parks, urban residential areas, commercial centers, high-rise buildings and temporary construction sites and other places.
Jun-26-17

Usa-Type Transformer Substation

$100.00K
MOQ: Not Specified
Supplier From Shanghai, Shanghai, China
 
USA-type Transformer Substation
Box-Type Transformer Substation
ZG(F)S series prefabricated substation, also called USA-type transformer substation, is an new-mode complete set of power distribution equipments that absorbs foreign advanced technology and design concept. It is also can be used in our national power girds, including these distribution systems of industrial and mining enterprises, high-rise buildings, residential areas, stations, port terminals, especially suitable for alteration of urban and rural power grids, not only reduces engineering investment and occupying area, but also shortens the installation period.
Products features
Novel design, innovative structure, smaller volume
The high voltage overload switch, plug-in fuse and backup protection fuses are placed in transformer insulating oil tank, thus substations volume becomes smaller whose occupying area is only 1/3-1/5 of normal products.
Fully enclosed, fully insulating, safe and reliable
Transformer oil tank is fully enclosed structure without conservator. The high voltage inlet wire adopts connections of elbow-type cable plug and high voltage bushing, live parts sealed within the insulator, shape a fully insulating structure. Terminal surface is zero potential which can guarantee human safety.
Advanced protection principle, economic and reliable, easy to operate
Using full range protection mode of double fuse in high voltage side and supplemented by low voltage undervoltage protection to make operation reliable and easy. The body of transformer is used with S11,S13 series, its winding adopts Dyn11,with characteristics of neutral point not drifting, good lightning performance, low loss, low noise, etc.
Jun-26-17

European-Type Transformer Substation

$100.00K
MOQ: Not Specified
Supplier From Shanghai, Shanghai, China
 
European-type Transformer Substation
Box-Type Transformer Substation
Product introduction:
XBF1,YBM series combination substation, is a complete set of equipment making the optimal combination for high voltage switch, power transformer and low voltage switch.
European-type transformer substation is with such advantages complete sets of strong, small footprint, low investment, easy installation and maintenance, attractive appearance, strong weather resistance, etc. Our company can design semi-submerged or buried whole type substation based on special conditions, so as to avoid blocking the line of sight, electromagnetic interference.
Normal operational conditions
a, environment temperature:-25C - +40
b, altitude less than 1000 meters;
c, relative humidity less than 90% (+ 25 ), to allow short-term up to 100%;
d, installation place without risk of fire, explosion, chemical corrosion and severe shock
e ,discuss with us for special operational conditions
Product structure and appearance
Jun-18-18
 
Prefabricated Outdoor Power Distribution Substation is mainly used for AC 50Hz (or 60Hz), voltage 1000V and below the circuit, under the rated load can be continuous long-term work. Usually used in machine tools, mechanical equipment as electrical control lighting and light.
The control transformer is working with the electromagnetic induction principle. The transformer has two sets of coils. Primary and secondary windings. The secondary coil is outside the primary coil. When the primary coil through the AC, the transformer core to produce alternating magnetic field, the secondary coil to produce induced electromotive force. The turns ratio of the Satons transformer coil is equal to the voltage ratio.
Dec-12-24
 
Transportation, installation and maintenance
Transportation
The factory substation should be filled with 25#(or 45#) transformer oil as indicated by the oil level gauge in the tank. During transportation and loading and unloading, it shall not be inverted or turned over, shall not impact the parts, and shall not be strongly shaken
Special attention should be paid to the lifting hook in the lifting hook of the fuel tank, and it should be lifted slowly to avoid damage to the paint on the surface of the substation by the wire rope, and even cause the center of gravity of the whole substation to shift, tilt, and fall.
Install
When the substation is installed on site, pay attention to the protection of the paint on the surface of the cabinet, do not allow the handle of the barometer, oil level meter, the thermometer, plug-in fuse and insulation sleeve element to bump, crack, etc., and the screws are not loose.
Clean the dust and dirt outside the substation, inside the cabinet door and on the surface of the insulation sleeve.
Check whether the name plate data and product certificate of the substation are consistent with the order, and check whether documents and spare parts are missing according to the packing list.
The civil diagram of the inlet and outlet of the substation cable is shown in Figure 6.
Maintenance
The factory products have been strictly adjusted assembly, do not need to be disassembled during installation, so as not to affect the performance, maintenance is limited to the following situations:
Sample analysis of transformer oil once a year;
It is found that the oil level should be supplemented in time, and the brand of oi l is the same as that in the box:
After the fuse is blown, the cause should be identified, and the specifications and models should be the same as the original specifications and models when replacing the melt core.
Jun-19-21
Supplier From Ludhiana, Punjab, India
Mar-25-19
 
ZS Series Rectifier Transformer,oil immersed power transformer,high quality oil transformer,oil immersed power thransformer
Oil Immersed Transformer
Rectifier transformers are widely used in electrolytic electrochemistry, transmission, traction, electrostatic precipitators, DC transmission and other systems which need direct current power supply. Our rectifier transformer absorbed the excellent experiences of same industry at home and abroad. Raw materials such as high magnetic silicon steel sheet and high quality oxygen free copper wire are used. We adopt production technology such as advanced integral assembly per phase for windings, the core are laminated by five step-lap method to reduce iron loss and noise, crimped winding connections, precision machining for tank surface and so on, which make technologic performance at the leading level in domestic. We can design and manufacture various types of products according to users requirement.
Model and Meaning
Technical Parameter of Rectifier Transformer
Model No. kVARated capacity Rated Voltage  Connection Group Symbol Weight|kg
KVgrid side VValve side Weight for Active parts Oil Weight Total Weight
ZSS-400/10 400 10 430 Dyn11 1015 380 1780
ZSS-500/6 500 6.3 400 Dyn11 1420 580 2800
ZSS-630/6 630 6.3 400 Dyn11 1550 620 3040
ZSS-650/3 650 3 3150 Dyn11 1255 540 2460
ZSS-800/6 800 6 400 Dyn11 1576 705 3045
ZSS-1000/6 1000 6 440 Dyn11 1837 838 3580
ZSS-1000/10 1000 10 420 Dyn11 2112 897 3860
ZSS-1250/10 1250 10 440 Dyn11 2205 1090 4410
ZSS-1500/10 1500 10 3300 Dyn11 2860 1205 5260
ZSS-1600/6 1600 6.3 400 Yyn11 2680 1145 5160
ZSS-1600/10 1600 10 420 Dyn11 3110 1150 5500
ZSS-1600/10 1600 10 660 Dd0 2750 1240 5310
ZSS-1750/10 1750 10 6300 Dyn11 2790 1190 5320
ZSS-1800/10 1800 10 650 Dd0 3060 1345 5795
ZSS-1900/10 1900 10 3300 Yd11 3353 1719 7180
ZSS-2000/10 2000 10 660 Dd0 3185 1990 7750
ZSS-2300/10 2300 10 420 Dyn11 3570 1495 7020
ZSS-2400/10 2400 10 750 Dyn11 3635 1535 7185
ZSS-2500/10 2500 10 630 Dyn11 4180 1582 7390