FDH-0601 Straight-run lubricant oxidation stability tester
Scope
Straight run lubricant oxidation stability analyzer based SH / T0185 design and manufacturing requirements, the two oxidation mounted sample tube into the heating temperature of 120 ° bath in oxygen 48H, volatile acids by the flow of oxygen blowing, water is absorbed. We need to determine the amount of volatile acid value, acid value and oil soluble precipitate after the end of oxidation. Oxidation stability is represented by the percentage of the total oxidation products.
Features
1, straight run lubricant oxidation stability analyzer using liquid crystal display, English operation interface
2, straight-run lubricating oil oxidation stability tester using SCM automatic control experiment without human duty
3, straight-run changes in lubricant oxidation stability analyzer assay of various parameters
4, straight run lubricant oxidation stability analyzer has a self-diagnostic function, suggesting operating functions
5, straight-run lubricating oil oxidation stability tester metal bath heating, environmental safety
Technical Parameters
1. Applicable standards: SH / T 0185
2, the heating method: heating tube
3, the control mode: Auto Control
4. Timing mode: SCM automatically record
5, results processing: automatically records storage Results
6, pressure display: LCD display real-time curve
7, Power supply: AC220V / 50HZ
8, Total Power: 2.5KW
Application GC-7960 Ethylene Oxide Residue Tester applies to test of solvent residue on various printing films, laminated films, extrusion films, various drug-use films and sheets as well as various kinds of sterilization apparatus and instruments. Standards YBB20162012ã?�YBB20172012ã?�YBB20182012ã?�YBB20252012ã?�YBB20262012ã?�YBB20272012 -
Product description The metal oxide arrester tester is used for the measurement and analysis of metal oxide arrester MOA leakage. It is mainly used for measuring the resistive current to analyze the degree of zinc oxide aging and damp. The field charged test shall conform to Electric Power Industry Standard of the People's DL474.5-92 Guide for Insulation Test on Site - Lightning Arrester Tests. The metal oxide arrester tester can be also used for factory and acceptance tests. Zinc oxide arrester tester Technical Indexes Range of reference voltage input peak 10V-200V Measurement range of full leakage current peak 100uA 10mA Measurement range of resistive current peak 100uA 10mA Measurement range of capacitive current peak 100uA 10mA Measurement range of angle 0-90 Power consumption 4W System measurement accuracy reading 5 5 words not more than 2m for harmonic current AC power supply AC 220V 10 50Hz 1 Precautions When measure the reference voltage from PT or the measuring end of the testing transformer, carefully check wiring to avoid the PT secondary or test voltage short circuit. Be careful not to wrongly connect the current and voltage sampling lines in the connecting process. In the laboratory experiment, the high voltage power supply cannot use the series excitation testing transformer.
Scope of application For flash and Fire points of all petroleum products, except fuel oils and those having an open cup flash below 79 C (175F). Benefits - Conforms to ASTM D92 and related specifications - For flash points above 79 C (175F) Function characteristics 1,english operating software prompts; 2, with the experimental date, test time parameter prompts; 3, automatic correction of atmospheric pressure and calculated correction values; 4 differential detection, automatic correction system deviation; 5, scan, ignition, detection, print test data computer is done automatically; 6, electronic ignition, the gas flame, forced air cooling detection of anti-fuel; standard wooden case
Supplier: Analogue and digital meters/transducers/energy meters, instrument transformer division like low tension current & voltage transformers, indoor medium voltage epoxy resin cast current & voltage transformers, outdoor oil cooled current & voltage transformers upto 132kv, high voltage break down tester, automatic power factor correction equipments, power system division like dry type lighting / isolation transformers, energy saving transformers, k rated transformers ultra isolation transformers, dimmerstat, servo controlled voltage stabilizers, rectifiers, current injection test sets
Buyer:
Supplier: Petroleum product analysis apparatus like flash point tester, oxidation stability tester, vacuum distillation tester
Application GTR-7004 tester is suitable for the analysis and determination of the porosity, the air permeance and the air resistance of various kinds of battery separation membranes, paper, paperboard, textiles, non-woven fabrics and other materials. Features Standard Gurley, Low Pressure Gurley, High Pressure Gurley Sheffield units, Bendtsen units Interchangeable test heads Output in seconds, other unit optional Embedded system, remote service Touch screen operation Test data and curve real time display Built in data query function Built in micro-printer to print reports Automatic overload protection. Highly accurate sensors to ensure the accuracy and repeatability. Swagelok piping system, to ensure system tightness and long-term stability Advanced control device, reliable operation and long service life Standard communication interface, configurable professional computer software The calibration can be traceable to ensure the measurability of the test data Support DSM system Technical indexes Test Range: 30,60,000 Gurley seconds,Standard, 0.0021,200um/Pa.s,Standard, 300,60,000Gurley seconds,Optional, 0,60,000 Gurley seconds,Optional, Resolution, 0.1 Gurley seconds Sample Amount, 1 ,Standard,,3 can be customized. Differential Pressure,0.01kPa,20kPa,STD,1.22kPa, Accuracy: 0.01kPa Test Area: 1.0in2. ,0.25in2, 0.1in2 optional, Sample Thickness: ,5mm Test Gas: Air, O2, N2, CO2,Self-provide, Gas Resource: 0.3MPa,1.0MPa Interface: Ф6mm Dimension: 320mm,L,�380mm,D,�410mm,H, Power Supply: AC 220V 50Hz Net Wt. 25 kg Standard ISO 5636.5,ASTM D726, TAPPI T460,TAPPI T536,TAPPI T538,TAPPI T490 Configuration Delivery,Mainframe, Test Head (1.0in2), Super Filter, Precision Pressure Regulator. Optional: Sample Auto Feeder, Calibration Equipment,Test Head(1.0in2), Test Head(0.25in2),Test Head(0.1 in2). Note: Specifications are subject to change without prior notice.
Supplier: Agriculture product and garment product, marine oil, ship engine oil low sulphur fuel, propulsion oil, high sulphur fuel, gl4 oil, water resistant oil, cycle rickshaw & thela, stabilizer, electronic voltage corrector
Summary The Arrester is suitable for testing the internal defects of 10KV and below 10KV MOA (metal Oxide Arrester).Before the annual season of thunderstormsit 's necessary to test metal Oxide using 1mA DC voltage and 0.75U1mA leakage current at Power plants/substations.The equipment was developped according to the requirement of site it 's integrated with DC HV supplymeasurement and control system. it has the characters of small size and light weight. Feature 1.Supply power: AC220V or Charging battery. 2.LCD display test datas. 3.Convenient to carry.
Application: TKBLQ-I zinc oxide arrester tester is a special instrument used to test the electrical performance of arresters. The instrument is suitable for live or power failure detection of arresters of various voltage levels, so as to timely detect the internal insulation damp and valve aging and other dangerous defects. TKBLQ-I zinc oxide arrester test instrument is easy to operate and easy to use. The whole measuring process is controlled by microcomputer. It can measure the total current, resistive current and its harmonics, power frequency reference voltage and its harmonics, active power and phase difference. The real waveform of voltage and current can be displayed on the large screen. Features: 1. 5.7 "320 Ã?? 240 LCD, high-speed thermal printer; graphic display, intuitive interface, easy to operate and use. 2. It is applicable to live arrester, power failure or laboratory. 3. The current and voltage sensors are completely isolated, safe and reliable. A, B, C three-phase arrester can be stored as a group of test data. 4. The instrument can test continuously, display voltage current curve, and print data and curve quickly. 5. The internal configuration memory can store 200 groups of test data when power down. 6. With RS232 communication interface, the test data can be exported through the upper computer. 7. High speed sampling frequency, advanced digital signal processing technology, strong anti-interference performance, high accuracy of measurement results. 8. It adopts dustproof, waterproof and anticorrosive engineering plastic sealing box, which is small in volume, light in weight and easy to carry.