Sanitary tri-clamp turbine flow meter Installation Instruction
Features
Measurement is not affected by the variation of flow density, viscosity, temperature, pressure and conductivity. High accuracy measurement is guaranteed according to the linear measurement principle.
No obstacle in the pipe, no pressure-loss and lower requirement for straight pipeline.
DN 6 to DN2000 covers a wide range of pipe size. A variety of liners and electrodes are available to satisfy different flow characteristic.
Programmable low frequency square wave field excitation, improving measurement stability and reducing power consumption.
Implementing 16 bits MCU, providing high integration and accuracy; Full-digital processing, high noise resistance and reliable measurement; Flow measurement range up to 1500:1.
High definition LCD display with backlight.
RS485 or RS232 interface supports digital communication.
Intelligent empty pipe detection and electrodes resistance measurement diagnosing empty pipe and electrodes contamination accurately.
SMD component and surface mount technology (SMT) are implemented to improve the reliability.
Meter diameter (mm): And the connection mode 25,40,50,65,80,100,125,150,200,250,300 use flange connection Precision grade ±1.5%R,±1.0%R,±0.75%R(special) Quantity range: 1:10;1:20;1:30 Instrument material: 304 stainless steel;Impeller: anticorrosive ABS or high quality aluminum alloy;Monitor: cast aluminum Measured medium temperature (?) : -30?~+80? Environmental conditions of temperature :-20?~+60? , relative humidity 5%~90% , atmospheric pressure 86 ~ 106 kpa The output signal Sensors pulse frequency signal, the low level 0.8 V or less, high level 8 V or higher two wire system 4 ~ 20 madc current signal Power supply VOLTAGE + 12 VDC and + 24 VDC (optional) + 24 VDC Display type instrument comes with 3 v lithium battery Signal transmission line STVPV3 x 0.3 (three-wire system), 2 x 0.3 (two wire) transmission distance =1000m Protection IP65 Explosion-proof grade basic ExdIIBT6
Electromagnetic flow meter Our Electromagnetic Flow Meter accurately measures the flow rate of conducting liquids or slurries flowing in closed pipes. Due to simple and right design the Electromagnetic Flow Meter is an obstruction-less & maintenance-free instrument in place of conventional mechanical flow measuring device. The use of "Pulsed DC" technology offers highest ability & better measuring accuracy in form of 4-20 mA DC linearly proportional to volumetric flow Features : Size DIN 10 to DIN 3000 NB pipe line. High Accuracy better than + 0.5% of reading. Zero pressure drop. Suitable for high viscosity conductive liquids. Digital flow rate / Totalizer Indication / Batching system Isolated Transmitting Output 4-20 mA. No Grounding Rings require. Minimum Upstream & Downstream straight length. Compact & Rugged, IP 65 protection. Remote flow indication totalizer / Batching system Data Logging & Wireless Data Transfer System through GSM Modem Applications : Effluent Treatment Plants. Sewage Treatment Plants. Water supply schemes. Steel & aluminum. Pulp & Paper. Chemical & Fertilizers. Food & Drug. Pumps & valve calibration lab. Dairy Industry. Corrosive liquids. Sugar industry. Sugar Industry. Textile and printing textiles Hotels & Resorts Water parks Buildings & Infrastructure Municipal corporation
This manual will assist you in installing, using and maintaining your flow meter. It is your responsibility to make sure that all operators have access to adequate instructions about safe operating and maintenance procedure. Operating Principle: Liquid flows through the turbine housing causing an internal rotor to spin. As the rotor spins, an electrical signal is generated in the pickup coil. This signal is converted into engineering units (liters, cubic meters, gallons etc.) on the local display where is applicable. Optional accessory modules can be used to export the signal to other equipment. Upon receipt, examine your meter for visible damage. The turbine is a precision measuring instrument and should be handled carefully. Remove the protective plugs and caps for a thorough inspection. If any items are damaged or missing, contact us. Make sure the turbine flow model meets your specific needs. For your future reference, it might be useful to record this information on nameplate in the manual in case it becomes unreadable on the turbine. Refer to the nameplate for your customized products specification. . Cautions for Installation turbine type flow meter 4.1 Mounting Positions â?¢ Pipes must be fully filled with liquids. It is essential that pipes remain fully filled at all times, otherwise flow rate indications may be affected and measurement errors may be caused Avoid Air Bubbles. If air bubbles enter a measurement pipe, flow rate indications may be affected and measurement errors may be caused Avoid all pipe locations where the flow is pulsating, such as in the outlet side of piston or diaphragm pumps. Avoid locations near equipment producing electrical interference such as electric motors, transformers, variable frequency, etc.
This manual will assist you in installing, using and maintaining your flow meter. It is your responsibility to make sure that all operators have access to adequate instructions about safe operating and maintenance procedure. Operating Principle: Gas flows through the turbine housing causing an internal rotor to spin. As the rotor spins, an electrical signal is generated in the pickup coil. This signal is converted into engineering units (liters, cubic meters, gallons etc.) on the local display where is applicable. Optional accessory modules can be used to export the signal to other equipment. Upon receipt, examine your meter for visible damage. The turbine is a precision measuring instrument and should be handled carefully. Remove the protective plugs and caps for a thorough inspection. If any items are damaged or missing, contact Make sure the turbine flow model meets your specific needs. For your future reference, it might be useful to record this information on nameplate in the manual in case it becomes unreadable on the turbine. Refer to the nameplate for your customized products specification.
X-meter mass flow meter
flow meter,better than KRACHT flow meter flow meter, better than KRACHT flow meter Now, the market of flow sensor is very hot. there exists about 80 factories located in the suburb of Dongtai city in Zhejiang province, the cluster of this industry. But the market there is also filled with chaos. Many companies live on purchasing components to reassemble; some company may think it too troublesome and the work as briefcase company to declare that they are manufactures of water flowmeter. This situation is worring. The so-called manufactures do not have their own calibrator at all, leave alone the accuracy of digital flow meter. Facing this complicated situation, the chief engineer, Mr. Tu Jianwen, who worked as a senior engineer in Siemens in Germany, came to Shanghai from his hometown Cixi in 2008. He was determined to create the world-class waterflowmeter and established Shanghai Cixi Instrument Co. Ltd by the name of his hometown. The waterflowmeter were produced and developed by the technology of Siemens numerical control system. Once upon a time, China, the world’s factory, is always the synonym with the “low quality”. Especially, the digital flow meter, which are used to control in automatic process are produced cumbersome and noisy and can not measure the sticky medium. Thus, whether the quality is stable has become users’ greatest concern. So, sometimes buying digital flow meter is like buying a lottery ticket. What’s more, the quality is left to chance and can not be guaranteed. That Shanghai Cixi Instrument Co. Ltd has introduced the technology from Siemens in Germany has greatly improved the quality of digital flow meter to the world leading level. To be frank, the accuracy if our products is double higher than the similar products in Japan. In digital flow meter, even the little screw holes or the gears and the watch cases are all accomplished by the Siemens’s technology of numerically controlled production center. Due to this, the production of flow sensor gets rid of the traditional manufacturing technique and will get landmark achievement. In our company, we have the stock of digital flow meter of all caliber. From this, it is not hard to find that our company has sufficient funds and our products sale good. Nowadays, there hardly exist companies who own the ability to keep stock. But we dare and have the strength to do that. Shanghai Cixi Instrument Co. Ltd has obtained 2 national invention patent. From the purchasing of raw materials to the process of quality controlling, we carefully check every producing and precision machining part. Before the flow meter leave the factory, we would test and calibrate them consistently. Every manufacturing process was installed and carried out strictly with the quality controlling system of USO9001. Our products own CE, SGS and other EU certificates.
Diameter DN3 to DN3000 Accuracy 0.5;1.0 Flow rate range 0.1~15m/s Conductivity =5µm/s Fluid temperature Ordinary rubber liner -20~+60? High temperature rubber liner -20~+90? Ptfe liner -30~+100? High temperature Ptfe liner -30~160? Power supply: 24VDC;220VAC Straight pipe requirements Pipe type: upstream=5D,downstream=3D Connection mode : Flange connection are between flow meter and piping that follows GB11988 rules Explosion-proof grade: Exd?CT4 Display : LED displayer
Technical specification: 1.Accuracy level: 1.0 2.Working pressure: 1.6MPa, 2.5MPa, 4.0MPa or higher 3.Application temperature: -40?~+350? 4.Pressure loss: resistance cd=2.4 5.Power supply: 12-24VDC 6.Explosive proof level: laiiCT6 (essential safety) 7.Data output: low voltage pulse=1V high voltage=6V standard current signal 4~20mA
Pipeline bore (mm) Throttling element 1st choice (set) 50, 80, 100, 125, 150, 200, 250, 300 2nd choice (25), 65, 175, 225, 275, 325 Throttling ß Standard orifice 0.44, 0.52, 0.65 Material 1st choice: 1Cr18Ni9Ti; 2nd choice: 2Cr13 Temperature range ? Water Environment temperature ? 0 ~ 50? Application temperature ? 0 ~ 100? Dry gas 0 ~ 50? -25 ~ 200? Wet gas 0 ~ 50? 0 ~ 500? Steam 0 ~ 50? 100 ~ 450? Pressure range Nominal pressure: 2.5MPa, 4.0MPa Relative Humidity =95% Flowing range Same as the traditional standard orifice flow meter Accuracy 1% Protection level IP65 Power supply 24VDC Holding part material 20# steel, A3 steel (optional), 1Cr18Ni9Ti (optional)