Diameter DN3 to DN3000
Accuracy 0.5;1.0
Flow rate range 0.1~15m/s
Conductivity =5µm/s
Fluid temperature Ordinary rubber liner -20~+60?
High temperature rubber liner -20~+90?
Ptfe liner -30~+100?
High temperature Ptfe liner -30~160?
Power supply: 24VDC;220VAC
Straight pipe requirements Pipe type: upstream=5D,downstream=3D
Connection mode : Flange connection are between flow meter and piping that follows GB11988 rules
Explosion-proof grade: Exd?CT4
Display : LED displayer
Electromagnetic flow meter Our Electromagnetic Flow Meter accurately measures the flow rate of conducting liquids or slurries flowing in closed pipes. Due to simple and right design the Electromagnetic Flow Meter is an obstruction-less & maintenance-free instrument in place of conventional mechanical flow measuring device. The use of "Pulsed DC" technology offers highest ability & better measuring accuracy in form of 4-20 mA DC linearly proportional to volumetric flow Features : Size DIN 10 to DIN 3000 NB pipe line. High Accuracy better than + 0.5% of reading. Zero pressure drop. Suitable for high viscosity conductive liquids. Digital flow rate / Totalizer Indication / Batching system Isolated Transmitting Output 4-20 mA. No Grounding Rings require. Minimum Upstream & Downstream straight length. Compact & Rugged, IP 65 protection. Remote flow indication totalizer / Batching system Data Logging & Wireless Data Transfer System through GSM Modem Applications : Effluent Treatment Plants. Sewage Treatment Plants. Water supply schemes. Steel & aluminum. Pulp & Paper. Chemical & Fertilizers. Food & Drug. Pumps & valve calibration lab. Dairy Industry. Corrosive liquids. Sugar industry. Sugar Industry. Textile and printing textiles Hotels & Resorts Water parks Buildings & Infrastructure Municipal corporation
Electromagnetic flowmeter is composed of sensor and converter. It has two forms: compact-type and remote-type. The remote-type also needs a special double-layer shielded cable to connect the converter and the sensor. There are seven kinds of electrode materials and four kinds of lining materials available for sensor.
Supplier: Electromagnetic flow meter
Supplier: Electromagnetic flow meter
Supplier: Electromagnetic flow meter, vortex flow meter, turbine flow meter, throttling device series
Services: Manufacturer
Sanitary tri-clamp turbine flow meter Installation Instruction Features Measurement is not affected by the variation of flow density, viscosity, temperature, pressure and conductivity. High accuracy measurement is guaranteed according to the linear measurement principle. No obstacle in the pipe, no pressure-loss and lower requirement for straight pipeline. DN 6 to DN2000 covers a wide range of pipe size. A variety of liners and electrodes are available to satisfy different flow characteristic. Programmable low frequency square wave field excitation, improving measurement stability and reducing power consumption. Implementing 16 bits MCU, providing high integration and accuracy; Full-digital processing, high noise resistance and reliable measurement; Flow measurement range up to 1500:1. High definition LCD display with backlight. RS485 or RS232 interface supports digital communication. Intelligent empty pipe detection and electrodes resistance measurement diagnosing empty pipe and electrodes contamination accurately. SMD component and surface mount technology (SMT) are implemented to improve the reliability.
This manual will assist you in installing, using and maintaining your flow meter. It is your responsibility to make sure that all operators have access to adequate instructions about safe operating and maintenance procedure. Operating Principle: Liquid flows through the turbine housing causing an internal rotor to spin. As the rotor spins, an electrical signal is generated in the pickup coil. This signal is converted into engineering units (liters, cubic meters, gallons etc.) on the local display where is applicable. Optional accessory modules can be used to export the signal to other equipment. Upon receipt, examine your meter for visible damage. The turbine is a precision measuring instrument and should be handled carefully. Remove the protective plugs and caps for a thorough inspection. If any items are damaged or missing, contact us. Make sure the turbine flow model meets your specific needs. For your future reference, it might be useful to record this information on nameplate in the manual in case it becomes unreadable on the turbine. Refer to the nameplate for your customized products specification. . Cautions for Installation turbine type flow meter 4.1 Mounting Positions â?¢ Pipes must be fully filled with liquids. It is essential that pipes remain fully filled at all times, otherwise flow rate indications may be affected and measurement errors may be caused Avoid Air Bubbles. If air bubbles enter a measurement pipe, flow rate indications may be affected and measurement errors may be caused Avoid all pipe locations where the flow is pulsating, such as in the outlet side of piston or diaphragm pumps. Avoid locations near equipment producing electrical interference such as electric motors, transformers, variable frequency, etc.
Oval gear flowmeter is one of the most common volumetric flowmeter. Has a long history, widely used in petroleum, chemical, food, pharmaceutical, paper making industry, ship. For the measurement of a variety of viscosity in the range of medium. Especially applicable to the measurement of low viscosity medium. Mechanical and electronic counter. Features: Shellmaterialhas a variety of options: aluminum, stainless steel and cast steel, PPS,bronze etc.; The rotorhas a variety ofmaterial: aluminum, iron, copper, stainless steel, Hastelloy alloy, graphite etc.; Bearing materialhas a variety ofoptions: graphite, ceramics, hard alloy, bronze,stainless steel seal bearing; O ringmade ofVITON, fluorine rubber, stainless steel, Teflon option; With mechanical,electronictwo counters, multiple output modes: pulse equivalent, 4-20mA, RS485, Hart etc.; GPS communication remote display and readout function optional Operational principles Measurement of elliptical gear flowmeter is composed of a casing and a pair of gearrotor and the upper and lower cover plate, a known volume of cavity between them as measure unit flowmeter. The slight pressure on the inlet of the gear rotor differential drive rotation, and will continue to import liquid through the cavity measurement to export. According to the rotation frequency rotor to counter (two meter), indicating the flow.
The metal tube ratometer flowmeter is a kind of variable area flow quantity measuring instrument. It has such features as small volume, large detection range and convenient operation. It is especially suitable to measure flow quantity of media with small flow velocity and small flow quantity. Intelligentized metal tube rotameters have field indication type and intelligentized remote transmission type. So it provides the customers with very wide selection spaces. In addition, advanced 16 bits micro processor and high quality industrialized components are adopted in the instrument, which ensures excellent performances of the flowmeter in various kinds of application situations.