Product Details:
Name:Auto transformer
Usage:Power
Phase:Three
Coil Structure:Thyroidal
Rated capacity:30-3000kvaT
Type:Oil immersed
Input Voltage:5-35kV
Output Voltage:0.4/0.23kV
Material:Copper
Cooling Method:Oil Natural
Frequency:50/60Hz
Rated voltage:20KV
Supplier: Transformers e:g high voltage transformer (35 66kv), furnace transformers (35 66kv), inverter/converter duty transformer(35 66kv), sll 50 3150/35 double winding non excitation voltage regulating distribution transformer, three phase oil immersed full seal without excitation voltage transformers
Services: Designing, engineering, and producing
Supplier: Electric transformers, 0.5~35kv indoor and outdoor cast type current, voltage transformer, combined transformer series, 10~ 110kv oil immersed current, voltage transformer series, 35~110kvsf6 gas insulated transformer series, 10~110kv electronic current, adjustable screw series, american trunk transformer, european box type transformer substation, oil immersed electric power of series 6 35kv, automatic tracing and tuning arc suppression device, pgl, ggd, gck, gcs distribution box, integrated dosing tank, plastic or round wire circlips series, spare parts series
Services:
Rated power: 320kVA Winding connection: Dyn11 Frequency: 50Hz Voltage: 22/0,4kV No-load losses (Po): 390 W Short-circuit losses(Pk): 3330 W Maximum no-load current(I0): 2% Short circuit voltage(Uk ): 6% Standard: : TCVN 6306 (IEC 60076); Decision 62 / Q EVN Quality standard: ISO 9001:2015; ISO 14001:2015
Transformer.
Supplier: Sugar, electric sanitizer dispenser, transformers, soybean, edible oil, masks, mineral water, bitumen, peanut oil, soya oil, rice bran oil, cashew nuts, corn, engineering goods.
Product description Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard technical parameter 1. Temperature: 2. Relative humidity 3. Rated Primary Current:5-5000A 5A,1A 4.Rated secondary current:5 1A 5 Accuracy Class 0.05S 6. Allow long-term work under the rated current; More than120A across the core. Precautions: 1. The current of standard CT and tested CT must be the same in CT calibration. 2. Follow the given wiring diagram strictly. 3. Test whether the load box is accurate or not before calibrating the transformer. 4. Forbid secondary winding opening during the calibration. 5. Select demagnetization before calibration.The wiring diagram is shown in figure 5. Short out the secondary winding before cutting off the power when the demagnetization is finished. 6.Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Product Introduction Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer. Product Parameters Technical parameters Rated Capacity 80kVA rated voltage 160kV Adjustable inductance range 65~130H Rated frequency 50Hz Rated current 0.5A Adjustable gap range 0~300mm
Product description Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard technical parameter Temperature -5 40 Relative humidity 80% Rated Primary Current 5-5000A 5A,1A Rated secondary current 5A 1A Accuracy Class 0.05S Allow long-term work under the rated current; More than120A across the core. Precautions The current of standard CT and tested CT must be the same in CT calibration. Follow the given wiring diagram strictly. Test whether the load box is accurate or not before calibrating the transformer. Forbid secondary winding opening during the calibration. Select demagnetization before calibration.The wiring diagram is shown in figure 5. Short out the secondary winding before cutting off the power when the demagnetization is finished. Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Used in current transformer & power transformer, also used in servo voltage stabilizer & variable auto transformer - dimmer or variac. As per customer requirement.