NO2-B43F Nitrogen Dioxide Sensor (NO2 Sensor) Description
Alphasense Nitrogen Dioxide gas sensors operate using proven fuel cell technology.
Sensors are available in the following sizes:
32mm diameter package, the best choice for fixed site applications
The NO2 range provides OEMs with reliable sensors for use in a number of high volume applications. Strong signal levels combined with low zero current allows resolution to 50 parts per billion (ppb) and an operating range to 20ppm. The sensors are suitable for use in fixed installation sensing heads, portable safety instruments, urban air monitoring and stack gas analysers.
The NO2 sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification.
* Range: 20 ppm NO 2 limit of performance warranty
* Sensitivity: -175 to -450 nA/ppm at 2ppm NO2
* Response time: < 60 t90 (s) from zero to 2ppm NO2
* Temperature range: -30 to 40'C
* Pressure range: 80 to 120kPa
* Humidity range: 15 to 85 % rh continuous
* Weight: < 13 g
NO2-A1 Nitrogen Dioxide Sensor (NO2 Sensor) Description Alphasense Nitrogen Dioxide gas sensors operate using proven fuel cell technology. NO2-A1 Nitrogen Dioxide Sensor size: 20mm diameter, the industry standard size for portable gas detectors The NO2 range provides OEMs with reliable sensors for use in a number of high volume applications. Strong signal levels combined with low zero current allows resolution to 50 parts per billion (ppb) and an operating range to 20ppm. The sensors are suitable for use in fixed installation sensing heads, portable safety instruments, urban air monitoring and stack gas analysers. The NO2 sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification. NO2-A1 Nitrogen Dioxide Sensor (NO2 Sensor) Specifications * Range: 20 ppm NO2 limit of performance warranty * Sensitivity: -250 to -650 nA/ppm in 10ppm NO2 * Response time t90: < 50 (s) from zero to 10ppm NO2 * Resolution: < 0.02 RMS noise (ppm equivalent) * Temperature range : -20 to 50 deg C * Pressure range: 80 to 120 kPa * Humidity range: 15 to 90 % rh continuous * Weight: < 6 g
Supplier: Wireless charger, batteries power bank, dust sensor, optical disc drive, tof, lidar, ar glass
Supplier: 1) plastic injection molded parts
2) mould design and development
3) automotive plastic parts
4) auto electrical parts
5) industrial/automotive battery parts
6) plastic household products
7) gear moulding
8) over moulding
9) insert moulding
Buyer: 1) copper plated/tin plated terminals for auto electrical parts.
We Can Supply Freestyle Libre 2 Flash Glucose Monitoring System Sensor Please Dont Hesitate to Contact Us in Case of Any Interested
3SP_NO2_20 C 15x15 NO2 Sensor 20 ppm C Package 110-502 3SP_NO2_20 C Nitrogen Dioxide Sensor NO2 Sensor Description SPEC Sensors' Screen Printed ElectroChemical sensor technology (SPEC Sensor) revolutionizes the current state of the art, enabling new applications in consumer and industrial safety monitoring. SPEC's printed sensors offer the performance of the best quality electrochemical sensors at a fraction of the price. SPEC's printed sensors are also ultra-thin, offering easy integration into wireless, portable, and networked solutions. These sensors are ideal for health, environmental, industrial and residential monitoring, because of their high performance, low cost and small size. 3SP_NO2_20 C Nitrogen Dioxide Sensor NO2 Sensor Benefits * Small Size with Low Profile (20 x 20 x 3 mm) * Long Life (10 years expected life) * Fast Response (< 15 seconds) * Low Power Consumption * Individually Calibrated (NIST Traceable) * ROHS Compliant 3SP_NO2_20 C Nitrogen Dioxide Sensor NO2 Sensor Applications * Air Quality Monitoring * Industrial Safety * Air Purification Control
Photocells Fans & ventilation, Hazardous area lighting Industrial plugs & sockets Industrial & commercial Lamps Light fittings: fluorescent, weatherproof & floodlighting Refrigeration & air conditioning spares Water heating elements Wiring accessories MCB's Circuit breaker Vacuum Breakers Control transformers Fuses & load break devices Hazardous area products Industrial beacons Industrial sounders, buzzers Industrial surge protection Safety switches Clamp meters Multi-meters Testers Semiconductors: thyristors, rectifiers Pressure switches Solenoid & pilot valves Photoelectric Sensors
Paraflex UNI-R Multistrand FR PVC Insulated Cu. Paraflex Multistrand FR/FRLS PVC insulated Cu. Paraflex round multicore Flexible PVC insulated Cu. Paraflex submersible (3-coreflat) and UNI-R Submersible PVC Insulated Cu. Paraflex Aluminum Unarmored, Single Core twin flat 3 core and 4 core round solid and XLPE Aluminum Twin flat (Heavy Duty) Paraflex PVX VIR Copper Cabales. Paraflex Co-Axial wires. Paraflex Oxygen Free speaker and camera wire. Paraflex twin flat and copper flexible cables. Paraflex PVC FR tape. to 630 sq.mm core, 2 core, 3 core, 3.5 core and 4 core both in Al & Cu. Under IS: 7098 (Part 1), IS: 1554 (Part 1). Aerial Bunch cable IS: 14255 range 16 sq.mm to 95 sq.mm. PVC Rigid Conduits IS 9537 Part-3, 2003
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Product Overview The ignition point of a fire inside the electric panel is mostly the part where the terminal block is fastened, so in order for initial fire extinguishing, the solution should be closely installed to the part where the terminal block is fastened. In the case of a small electric panel, a complete initial fire extinguishing is expected for fires occurring inside the electric panel by attaching the SFEX Pad to the top surface of the electric panel. Product Feature It has an excellent performance in the initial fire suppression as it can be installed near the ignition point as a flexible rope type. It uses a stand-alone method based on polymer chemistry so that it does not cause malfunctions and maintenance costs. The thermo-responsive Granule composed of KNO3 and subsidiary catalysts It does not affect the peripherals after the fire goes out. Function of SFEX Granule = fire extinguishing agent storage tank + temperature sensor + nozzle function Fire extinguishing method : Suffocation + subsidiary catalyst Example of Installation 1 : SFEX Line - If ducts exist Installing the SFEX Line horizontally or vertically in the ducts closest to the expected ignition points It can be installed without damaging the panel Example of Installation 2 : SFEX Line - If ducts do not exist Installing the SFEX Line horizontally or vertically, close to the expected ignition points of the Electric panel Example of Installation 2 : SFEX Pad - Small Electric Panel Simply attach it to the top inside the Electric panel.