Carbon Monoxide Detector And Transmitter
Model#: F2000TSM-CO-C101
* Real time detect and transmit ambiance carbon monoxide level
* Up to more than five years lifetime
* 1x analog output for linear measurement
* Modbus RS485 interface
* The highest performance with the lowest price
F2000TSM-CO-C101 Carbon Monoxide Detector and Transmitter Description
F2000TSM-CO-C101 is specifically designed to detect and transmit carbon monoxide level in the enclosed or semi-enclosed car parks and to regulate the environment according to the measurement of carbon monoxide. It is designed for easy installation and minimum maintenance during operation.
F2000TSM-CO-C101 Carbon Monoxide Detector and Transmitter Features
* Wall mounting, real time detect CO level with measuring range of 0~100ppm/ 0~200pm/ 0~500ppm.
* Electrochemical sensor which offer several advantages over traditional electrochemicalsensors.
* With a long life, good long term stability, and high accuracy, the CO sensor is environmentally friendly without risk of electrolyte leakage.
* With simple calibration
* The special design of easy sensor's replacement makes customers replace sensor easily by themselves
* Full time CO level detection, even the slightest leak can be detected
* One analog output of the measurement of carbon monoxide concentration with 0~10V/4~20mA selectable
* Special built-in Self-Zero Correction algorithm.
* Modbus RS-485 communication with 15KV antistatic protection, also can be calibrated carbon monoxide measurement via the interface
F2000TSM-CO-C101 Carbon Monoxide Detector and Transmitter Application
* Residential and commercial CO detectors and transmitters
* Ventilation control for indoor parking garages
* Recreational vehicle CO detectors
* Kitchen rooms and restaurants
* Freezing machine rooms and other places where air quality is easy to worsen
F2000TSM-CO-C101 Carbon Monoxide Detector and Transmitter Specifications
* Gas detected: Carbon monoxide
* CO Measuring Range: 0~100ppm(default); 0~200ppm/0~500ppm selectable
* Response Time: Within 60 seconds
* Accuracy:
> User configurable CO ranges up to 1000 ppm > Optional 4-digit dual row LCD display to display carbon monoxide value in ppm > Field replaceable CO sensor > Health / status (Heartbeat) LED > DIP selectable Loop powered current output or voltage output available > Optional dual 2-wire output available > IP65 protection for enclosure > Wall mount arrangement > Internal switch provided to adjust zero ppm >DIP for range selection
Supplier: Supplier for a wide range of products including mobile phone accessories, used mobile phones, laptops, gaming equipment, various types of uniforms, clothing, and scrap materials
Good quality LCD/LED monitors and touch screen monitors with CE/ROHS certification. Competitive price.OEM and ODM accepted.
Supplier: Laptops, desktops, computer pcs, printers, scanners, ups, led monitors, cisco networking products, storage and solutions, processors and memories, copier machines, cctv's, ubiquiti, perfumes, thermal rolls, a4 papers, stationery, perfume/ body spray
Differential Transmitter In All Brand Emerson , Rosemount , Honeyweel , F+h , E+h Etc
Long battery life. By stand-by mode, battery lasts 1000h. Power switch remotely controllable. You can control on/off of rcs-50 by rcs-20t. Controllable range is nearly 100m. Original code between rcs-50 (transmitter) and rcs-20t (remote controller) avoid interference with the other unit if someone use it in the same area. bug detectors can not detect sleeping transmitter. (RCS-50) Size... 67 x 21 x 70 (73)mm / antenna °3 x 220mm Weight... 162g (with alkaline batteries) / antenna 3g Power supply... "006p" (6f22/6lr61) 9v battery x 1 Battery life... Approx. 62h (6lr61, continuous transmission) / approx. 1000h (stand-by mode, no transmission) Available channels... Uhf-a, uhf-b Mic effective range... 15m from circle point. (RCS-50) Size... 42.5 x 21 x 112 (120) mm / rod antenna 20mm (shortened) - 460mm (extended) Weight... 162g (with alkaline batteries) / antenna 3g Power supply... "006p" (6f22/6lr61) 9v battery x 1 Battery life... Approx. 11h (6lr61, continuous transmission) Controlling rcs-50... Keep pressing button 5 seconds to turn on rcs-50. Same procedure to turn it off. Rcs-20t uses vhf frequency for remote control.
Supplier: Laptop spare parts e.g.: laptop LCD panel, laptop batteries, laptop AC adapters, laptop keyboard, mainboard, optical disk drive
Pressure Transmitter for Sandvik LH307/LH410
Notice 1. All the supplied products are provided with product certificates and instructions, including product number, technical parameters, wiring diagram,factory date, etc. Please check carefully to avoid misuse. 2. Installation should check whether the field interface is connected to the product according to the connection mode and thread type of the product.The mouth is the same. If it is a threaded interface, it should be tightened slowly and sealed carefully. Torque can not be added directly to the transmitter shell, but only on the six sides of the pressure interface. 3. The wiring should be strictly in accordance with the instructions of our company. 4.This product is a precise instrument. It is forbidden to disassemble, colide,fall,throw hard or punch the drainage hole with a sharp instrument. 5. The transmitter can work by electricity, but the preheating output is stable for 30 seconds. 6. If any abnormality is found in use, the power supply should be turned off, the use should be stopped, the inspection should be carried out, or contact our technical department direct. 7.When transporting and storing, the original packaging should be restored and stored in a cool, dry and ventilated warehouse. 8.The quality assurance period is 12 months. Intelligent Operation Method 1. LCD shows the output percentage or process pressure. Press the S key to select the display percentage or pressure.Press Z key to select pressure unit KPa or Mpa when displaying pressure. 2. Press S+Z key for 8 seconds, then release it at the same time, press Z key to set the zero value; Press the S key set the range. note: this function can only be triggered once an operation. 3. Adjustments to zeros or ranges may cause changes in the displayed options, i.e.The percentage being displayed becomes pressure or KPa becomes Mpa, etc. All these changes are shown only in the display, and have no effect on the internal parameters of the transmitter, pressure detection and current output. After adjusting the zero point and range, the S and Z keys can be used to select the desired percentage or pressure. 4. Zero-setting in field pressure-free state: 30 seconds after pressing S+Z key, the display shows zero time at the same time release the two keys, that is, zero. Simulated operation method 1.Zero-setting in pressure-free condition: The potentiometer with the word "zero" on the circuit board is adjusted to zero when it is displayed on the spot.(Note: Clockwise increase, counterclockwise decrease) 2.The potentiometer marked "range" on the circuit board can not be adjusted without standard pressure, so as to avoid the disorder of measurement range.