GDBC-901 Multi Function Transformer Turns Ratio Tester
It is designed according to IEC76-1,IEC60044,and GB/T1094 standard.It could be applied to test the ratio of single or three phase transformer.Also the connection group of three phase transformer could be calculated with the ratio.All parameters are measured in one test for three phase transformer.
Functions
1. The voltage ratio measurement for three or singe phase transformer
2. The group vector measurement for three phase transformer.
3. The polarity measurement for single phase transformer or CT/PT
4. Voltage ratio error calculation
5. Current transformer ratio measurement
6. Excitation current measurement in ratio testing
7. Reproduction the AC test voltage from power source to reduce the effects of bad power source
8.Save the test results in the memory internal the tester
9. Print the test results by micro printer
10. Reverse connection detect unit to prevent the high voltage injected to operator
11.Over current protection unit integrated in software and hardware
12. Upload the test results to PC by RS232 and make word report by software
Technical index
1. Ratio measurement range:1~10000
2.Group measurement:1~12
3.Phase measurement error:1 degree
4.Ratio measurement error:1~2000 ± 0.2%RDG 2000~10000 ± 0.5%RDG
5.Test voltage:0~80V
6.Power supply:AC220V ± 10%, 50Hz/60Hz
7.Humidity: â?¤85%R
8.Size 400*350*200 mm
9.Weight: 7kg
Company Information
Our company has become one of the leading manufacturer of petroleum testing instrument and electrical testing instrument since 2009sâ??.
We have developed sales channels in many countries such as Malaysia,India,Germany,USA,Mexico,Saudi Arabia,South Africa and other countries worldwide. and we have gained great advantage and high reputation in international market.
We are making effort to develop together with customers from both domestic and abroad on the basis of reciprocity.Client,quality and service are our supreme target.
Our Services
Pre-sale Service:
Inquiry will be replied within 24 hours.
Welcome to visit our factory.
Technical datas and operation manual sent for evaluation.
After-sale Service:
Training how to instal the machine, training how to use the machine at our factory;
Engineers available to service machinery overseas at customers' cost;GDBC-901 Multi Function Transformer turns ratio Meter TTR tester
Product description Current transformer field tester was developed with high-end testing technology, large-scale electronic circuit design and accord with national related protocol . It has solved the problem of big working intensity,trival operation while on-site test of current transformer, voltage transformer. Meanwhile the product has a reliable performance,and the function is strong. Technical index Test range: 5A5A~25000A5A or 5A1A~5000A1A Tested current transformer work scope: 1% 120% Second load 2.5 VA 300VA, COS 0.8 1.0 Be tested current transformer accuracy range 1.0, 0.5, 0.5 S, 0.2 and 0.2 S Resistance, admittance measurement errors 5.0% Measurement range R 0.00 ~20.0 Y 0.000mS~100.0 mS Power consumption 20 VA Accuracy level 0.05 S level Shape dimension mm 460 L 375 W 183H Weight kg 10 Feature HCCT-H Current Transformer Field Tester with recursive method to measure current transformer error, as well as potential difference method to measure voltage transformer error function, convenient for carrying out calibration work of field metering device. HCCT-H Current Transformer Field Tester without using Standard Current Transformer, Current Source, Load Box, Double Adjustable Control Box and Primary cable, using extremely simple test connection and operation to realize the current transformer test, greatly reduce work intensity and improve the work efficiency, convenient to carry out current transformer field test work.
Product description The current booster is used on checking current transformer,to be the power source supply once current for current transformer or to be other 50Hz single phase current source device. Technical index Temperature Humidit Capacity: 20kVA Specification Weight: 75Kg Allow long-term work on the rated current Allowable overload 1.5 times,30 minutes of continuous work. Feature This PSLLQ is make up of input Winding(220V), output winding below 100A and CXRZ. Output current indicated on the nameplate is defined the rated current that through winding allow to pass.When CX many circles, the rated current its permitted to pass through will inversely decline. The value which ouput capcity divided by product of output current and each circle voltage was the biggest circle number allowing. The current booster is designed to provide the primary current power supply for the current transformer when verifying the current transformer or as other 50HZ single-phase power equipment. The current booster for transformer verification is suitable for power departments such as power testing, power measurement, and power maintenance. The current booster is developed and produced according to the industry standard of transformer error testing, and is used as a current transformer to verify the primary current of the current transformer. The output current can be customized according to customer requirements. The lifter is equipped with casters for easy on-site movement.
Product description Current transformer field tester was developed with high-end testing technology, large-scale electronic circuit design and accord with national related protocol . It has solved the problem of big working intensity,trival operation while on-site test of current transformer, voltage transformer. Meanwhile the product has a reliable performance,and the function is strong. Technical index
Product description The Transformer short circuit impedance tester comes with an adjustable power output. Regardless of single phase or three phase transformers, only one connection is required, and the instrument can complete the measurement of all winding pairs. The test and connection are simple. Main technical indicators and conditions of use Measurement accuracy voltage, current 0.2 level Power COS 0.1 0.5 grade, COS 0.1 1.0 grade Impedance COS 0.1 0.5 grade COS 0.1: 1.0 grade Voltage measurement range AC 3V 300V Internal power output range voltage 0 250V, current 0 10A Current measurement range AC 0.2A 20A Working temperature 10 50 Working humidity 0 80 Working power supply AC220V 10 50Hz 1Hz Dimensions 360mm 220mm 150mm Weight of the instrument 20Kg Transformer Short circuit Impedance Tester
Supplier: Distribution transformers, instrument transformers, HV tester, testing equipment
Photocells Fans & ventilation, Hazardous area lighting Industrial plugs & sockets Industrial & commercial Lamps Light fittings: fluorescent, weatherproof & floodlighting Refrigeration & air conditioning spares Water heating elements Wiring accessories MCB's Circuit breaker Vacuum Breakers Control transformers Fuses & load break devices Hazardous area products Industrial beacons Industrial sounders, buzzers Industrial surge protection Safety switches Clamp meters Multi-meters Testers Semiconductors: thyristors, rectifiers Pressure switches Solenoid & pilot valves Photoelectric Sensors
Overview In the power system factories and enterprises have a large number of electrical equipment. Most of its internal insulation is oil-filled insulation type. Dielectric strength test of insulating oil is a necessary routine test item. In order to adapt to the rapid development of the power industry our company is the first in China to develop a fully automatic oil dielectric strength test system. This series of products according to the latest national standard GB t507-2002 the power industry standard dl429.9-91 and the latest power industry standard DL t846.7-2004 design and manufacture using microcomputer control mechanical and electrical integration of all automation high test accuracy greatly improve the work efficiency but also greatly reduce the labor intensity of the staff. It is agreed that this series of products is the ideal insulation oil voltage test equipment in China. Specification Technical Parameters Power supply voltage AC 220V22V Power frequency 50Hz 2.5Hz Work rate 200W output voltage 0-80kV Booster capacity 1.5kVA Booster speed 2.0 2.5 3.0 3.5kV s adjustable Total voltage distortion 3 Installation dimensions 470 390 420mm3 Weight 40kg Conditions of Use Environment temperature 40 Relative humidity 80 Capacity of the oil cup 200ml Distance between the electrodes 2.5mm
Supplier: Analog panel meters, digital panel meters, electrical transducers, current transformers, digital multimeters, insulation testers, power analyzers
Supplier: ZYD transformer oil filtration machine, ZY insulating oil purifier, ZYM mobile trailer-type transformer oil purification systems, IIJ-II insulating, transformer oil dielectric strength tester, TYA lubricant, hydraulic, turbine oil filtration machine, TJ coalescence and separating oil treatment plant, AD air dryer for drying electric equipments, NKVW vacuum system for vacuum transformer, TPM oil dehydration plant