GDBC-901 Multi Function Transformer Turns Ratio Tester
It is designed according to IEC76-1,IEC60044,and GB/T1094 standard.It could be applied to test the ratio of single or three phase transformer.Also the connection group of three phase transformer could be calculated with the ratio.All parameters are measured in one test for three phase transformer.
Functions
1. The voltage ratio measurement for three or singe phase transformer
2. The group vector measurement for three phase transformer.
3. The polarity measurement for single phase transformer or CT/PT
4. Voltage ratio error calculation
5. Current transformer ratio measurement
6. Excitation current measurement in ratio testing
7. Reproduction the AC test voltage from power source to reduce the effects of bad power source
8.Save the test results in the memory internal the tester
9. Print the test results by micro printer
10. Reverse connection detect unit to prevent the high voltage injected to operator
11.Over current protection unit integrated in software and hardware
12. Upload the test results to PC by RS232 and make word report by software
Technical index
1. Ratio measurement range:1~10000
2.Group measurement:1~12
3.Phase measurement error:1 degree
4.Ratio measurement error:1~2000 ± 0.2%RDG 2000~10000 ± 0.5%RDG
5.Test voltage:0~80V
6.Power supply:AC220V ± 10%, 50Hz/60Hz
7.Humidity: â?¤85%R
8.Size 400*350*200 mm
9.Weight: 7kg
Company Information
Our company has become one of the leading manufacturer of petroleum testing instrument and electrical testing instrument since 2009sâ??.
We have developed sales channels in many countries such as Malaysia,India,Germany,USA,Mexico,Saudi Arabia,South Africa and other countries worldwide. and we have gained great advantage and high reputation in international market.
We are making effort to develop together with customers from both domestic and abroad on the basis of reciprocity.Client,quality and service are our supreme target.
Our Services
Pre-sale Service:
Inquiry will be replied within 24 hours.
Welcome to visit our factory.
Technical datas and operation manual sent for evaluation.
After-sale Service:
Training how to instal the machine, training how to use the machine at our factory;
Engineers available to service machinery overseas at customers' cost;GDBC-901 Multi Function Transformer turns ratio Meter TTR tester
GDKF Transformer Load and No Load Tester
Introduction:
It's used to Measure the transformer load and no load current, load and no load loss, short-circuit voltage, short circuit (load) losses and capacity.
Test items:
RMS phase voltage
Average value of three-phase AC voltage
Three-phase current RMS
Percentage of no-load loss and no-load current
Load loss, impedance voltage, and the percentage of short-circuit impedance
Any given temperature, load loss, the percentage impedance voltage and short circuit impedance
Voltage waveform in the percentage of each harmonic component
Current waveform in the percentage of each harmonic component
Technical index:
Current measurement range: 100mA ~ 5A, accuracy class 0.2;
Voltage Range: 10V ~ 650V, accuracy class 0.2;
External transformer can broaden the scope of measurement instruments;
Frequency Range: 40 ~ 65Hz, accuracy class 0.2;
Power Input: AC220V ± 10%
Company Information
Our company has become one of the leading manufacturer of petroleum testing instrument and electrical testing instrument since 2009sâ??.
We have developed sales channels in many countries such as Malaysia,India,Germany,USA,Mexico,Saudi Arabia,South Africa and other countries worldwide. and we have gained great advantage and high reputation in international market.
We are making effort to develop together with customers from both domestic and abroad on the basis of reciprocity.Client,quality and service are our supreme target.
Our Services
Pre-sale Service:
Inquiry will be replied within 24 hours.
Welcome to visit our factory.
Technical datas and operation manual sent for evaluation.
After-sale Service:
Training how to instal the machine, training how to use the machine at our factory;
Engineers available to service machinery overseas at customers' cost;GDKF Transformer Load And No Load Capacity Characteristic Tester
Introduction:
GDGY is a high-precision instrument, which can be applied to measure dielectric loss angle and Volume Resistivity of insulating oil etc. It is integrated by oil cup for dielectric loss, temperature-control equipment,temperature sensor, test-bridge for dielectric loss,AC trial electrical source,standard capacitor,high resistance meter and DC high-voltage power etc.
The most advanced heating mode of high frequency induction is applied to the heating part of this instrument, which has the advantage of non-contact of oil cup and heating unit, homogeneous heating, quick velocity and convenient control etc. AC-DC-AC conversion mode is applied to AC trial electrical source so that the problem how to measure correctly under the fluctuation of voltage and frequency can be avoided. Even when the electric generator is working, the instrument can operate correctly.
The inner standard capacitor is SF6 three-pole inflate capacitor, whose dielectric loss and capacitance is not influenced by environmental temperature and dampness etc. In this way, the accuracy of the instrument is guaranteed conformably after a long-time application.
Introduction:
GDGS Automatic Transformer Power Factor and Tan Delta Tester is applied to measure the dielectric loss and capacitor value of insulation materials in high voltage power equipment. The non-power frequency voltage source is integrated in the tester to avoid power frequency interference. That make the tester has a good performance in measurement precision.
Technical Index:
1. Measurement error:
Capacitor value: 1%RDG+5pf
Tangent delta: 1%RDG+0.04%
2. Output voltage:AC 0.5kV~10KV
3. Testing voltage setting resolution: 0.5kv
4. Maximum output capacity: 200mA
5. Testing frequency: 45Hz/55Hz
6. Test mode: fully automatic
7. Power supply: AC220V±10 % 50Hz/60Hz
8. Environment temperature: 0~50°C
9. Humidity: â?¤85%RH
10. Weight:40KG
Our Service
Pre-sale Service:
Inquiry will be replied within 24 hours.
Welcome to visit our factory.
Technical datas and operation manual sent for evaluation.
After-sale Service:
Training how to instal the machine, training how to use the machine at our factory;
Engineers available to service machinery overseas at customers' cost;
Product Description:
This tester with standard 4 phase voltage,3 phase current output, voltage 125V/phase, current 40A/phase, 3 phases in parallel can up to 120A. Digital Signal Processor Microcomputer. Not only test the traditional relays and protectors, but also test modern micro computer replays,special for transformer differential protection and transfer equipment.
All technical indicators meet the standard DL/T624-1997: Technical condition of the relay computer test device.
Technical Index:
1. AC current source
Phase current output (effective value): 0~40A/phase, accuracy 0.5%.
3 phase parallel current output (effective value): 0~120A/3 phase parallel output in same phase
Phase current working value for allowed long time (effective value): 10A
Maximum output power of each Phase: 420VA
Maximum output power of 3 parallel current: 900VA
Maximum permitted work time of 3 parallel current: 10S
Frequency range: 0~1000Hz; accuracy: 0.001Hz
Harmonic time: 2~20; phase: 0--360°; accuracy: 0.1°
2. DC current source
Current output: 0~±30A / phase, accuracy:0.5%
3. AC voltage source
Phase voltage output (effective value): 0~125V/phase, accuracy: 0.5%
Line voltage output (effective value): 0~250V
Phase voltage / Line voltage output power: 75VA / 100VA
Frequency range: 0~1000Hz accuracy: 0.001Hz
Harmonic time: 2~20; phase: 0--360°; accuracy: 0.1°
4. DC voltage source
Phase voltage output range: 0~±150V accuracy: 0.5%
Line voltage output range: 0~±300V
Phase voltage / Line voltage output power: 970VA / 180VA
5. Switch terminal
Switch input terminals: 8 pairs
Dead contact: 1-20mA, 24V active output inside the device.
Potential flip: 0--6V DC low level
15-250V DC high level
Switch output terminals: 4 pairs, dead contact, rupturing capacity: 110V/2A, 220V/1A
6. Time measurement range
Range: 1ms-9999s; accuracy: 1ms
7. Dimension & weight
Dimension: 455 (mm)Ã?530 (mm)Ã?220 (mm)
Weight: 20Kg.
8. Power
AC220V±10% 50Hz 10A
Our Service:
Pre-sale Service:
Inquiry will be replied within 24 hours.
Welcome to visit our factory.
echnical datas and operation manual sent for evaluation.
After-sale Service:
Training how to instal the machine, training how to use the machine at our factory;
Engineers available to service machinery overseas at customers' cost;
Packing & Delivery
GDYJ-501 Transformer Oil Breakdown Voltage Tester
In power system,railway system and large petrochemical factories and mines,enterprises have a lot of electrical equipment,its internal insulation are mostly oil filled insulation type,dielectric strength of the insulating oil is a routine test shall be measured.
GDYJ-501Transformer Insulating Oil Breakdown Voltage BDV Tester is mainly test the Breakdown Voltage of those insulating oil.
Standard: IEC60156
Functions
Transformer oil dielectric strength tester functions:
1 .Breakdown test of user-defined
2 .Proof test
3 .Calibration interface for customers
4 .Uploading data to PC and making word report automatically.
5 .Result print
Technical index
1. Output voltage: AC 0~80KV
2 .Rate of voltage rise: 2KV/s±10%
3 .Measuring precision: 3%RDG+0.3%FS
4 .Test times setting: 1-9
5 .Mixing time setting: 0~99 second
Waiting time setting: 0-9 minute 59second
6 .Maximum storage capacity: 100 groups of test data
7 .Display: 256*128 LCD
8 .Rated power supply: AC 220V±10% 50Hz/60Hz
9 .Environment temperatures: 0-50°C
10.Relative humidity â?¤80%RH
GDZC- Series Transformer DC Winding Coil Resistance Meter
It is applied to measure the DC resistance of inductance circuit such as power transformer coil,current transformer coil and so on.
Also the tester could be applied to measure the cable resistance in 4-wire mode
GDZC Series 1A to 50A Transformer Winding Resistance Meter uses Constant current source to measure the DC resistance of inductance circuit such as power transformer coil, current transformer coil and so on.
GDZC Series 1A to 50A Transformer Winding Resistance Meter has functions of self test, data processing, discharge rapidly, result print and so on.
Functions
A new switching power supply technology makes output current more stable and power larger than before.
The tester has an advanced signal process circuit which has a good performance at anti-noise. Test data is precise and stable.
The tester has protections to prevent circuit over-current, circuit over-voltage, wrong operation, discharge and so on.
Small size, light weight and more suitable for outdoor using.
Varies levels of output current make measuring range more wide.
Large-screen LCD makes operation easy.
Company Information
Our company has become one of the leading manufacturer of petroleum testing instrument and electrical testing instrument since 2009sâ??.
We have developed sales channels in many countries such as Malaysia,India,Germany,USA,Mexico,Saudi Arabia,South Africa and other countries worldwide. and we have gained great advantage and high reputation in international market.
We are making effort to develop together with customers from both domestic and abroad on the basis of reciprocity.Client,quality and service are our supreme target.
Our Services
Pre-sale Service:
Inquiry will be replied within 24 hours.
Welcome to visit our factory.
Technical datas and operation manual sent for evaluation.
After-sale Service:
Training how to instal the machine, training how to use the machine at our factory;
Engineers available to service machinery overseas at customers' cost;
GDRZ-902 Transformer Sweep Frequency Response Analyzer
Introduction:
The structure and reference of the transformer is fixed after been made, Therefor, the frequency
response of each winding will be almost the same normally;
Some case such as cut off between circles or phases in experience, cut off or winding moved for the
pull of power in running, winding moved for hit in transportation, could change the reference of the
transformer ,of which the frequency response will be changed, we could detect the deformation
according to the frequency response curve;
Our company has designed the winding deformation tester base on the idea and the advanced technique;
It could draw the frequency response curve accurately. Then we compare the curves horizontally or
vertically to detect the deformation of the transformer;
The tester is conformed to the standard of DL/T911 2004;
GDRZ-902 Sweep Frequency Response Analyzer for transformer distortions detection
Features:
Using the advanced technical of DDS;
Using the high speed and advanced microprocessor to design;
Using double channels of AD chip of 16 bits;
With seven inch LCD touch screen of which the brightness can be adjusted;
With thermal printer of which the print thick can be adjusted;
It could store one hundred and twenty groups of data, which could be read to current screen or upload to the PC;
With PC software using which we could upload data ,test, analyze data, print data, or create word document;
Using USB2.0 to connect to the device;
Tester dimension: 31cm * 15cm * 15cm;
Weight: 4.0KG;
Specifications
1Sweep modes Linear sweep,Section sweep
2Linear sweep 0.5KHZ-1MHZinterval 0.5KHZ 2000 dots
3 Section sweep
l 50HZ-100HZinterval 2HZ25 dots;
l 100HZ-1KHZinterval 20HZ45 dots;
l 1KHZ -10KHZinterval 50HZ180 dots;
l 10KHZ-100KHZinterval 0.2KHZ 450 dots;
l 100KHZ â?? 500KHZ interval 0.5KHZ 800 dots;
l 500KHZ â?? 1000KHZ interval 1KHZ500 dots;
4Test range (-100dB) - (+20dB)
5Test accuracy 0.1dB
6 Frequency accuracy1M Ω
8Signal output impedance 50 Ω
Introduction:
The tester can record switch operation waveform in overall process. The longest time is 6.4s.It can test various parameters such as transition waveform, transition time, transition resistance and three phase synchronization one time and analyze results automatically. It has power-off protection, over-voltage protection, perpetual clock and high-speed printing.
Functions:
1. Test transformers of type Y0 Y and display resistance value directly;
2. Automatically analyze waveform fault and mark the fault.
3. Automatically adjust resistance value and time range according to sampling data
4. Transformer type is able to display to synchronization status of three phase;
5. Be able to test with winding or without winding;
6. Four terminal connection mode and provide high accuracy of resistance measurement.
7. Continuous test to save time of power off
8. Make word report
9. 800Ã?480 colorized LCD with touch screen and high speed printer
10. Store 1000 groups of data and also can be saved by USB flash disk
Technical Index:
1. Three phase constant current source charge,charge current: 3A/1A; 0.6A/0.2A
2. Maximum voltage of the port: 24V
3. Maximum range of transition resistance: 100
4. Measuring range: 1A:0.4~20 0.2A:10~100
5. Record time of waveform:300ms
6. Sample rate: 30k
7. Resolution of time:0.1ms
8. Resolution of resistance: 0.1
9. Accuracy of transition resistance: ±5% Reading±0.1
10. Accuracy of transient time: ±0.5% Reading±0.2mS
11. Temperature: -10-40°C Humidity:
GDVA-404 Portable current transformer voltage transformer CT PT analyzer
Tests for Current Transformer:
1. Excitation curve and parameters test
2. Turns ratio test
3. Ratio and phase error test
4. Polarity mark check
5. Winding resistance measurement
6. Secondary loop burden measurement
7. Error line curve test for protection CT
8. Transient CT parameters test
9. CT nameplate guess
10. Saturation hysteresis loop curve measurement
Tests for Potential Transformer:
1. Turns ratio test
2. Ratio error and phase angle error test
3. Polarity test
4. Secondary burden test
5. Winding resistance test
Applications of CT/ PT Analyzer:
1. CT nameplate check
2. CT parameters check in work burden
3. CT transient parameters analysis
4. CT ratio and phase error calibration
5. PT routine test
Main specification:
1. Test standards: IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
2. Power supply: AC220V±10%,50Hz/60Hz±10%
3. Power output: 0.1~125V (AC)
4. Current output: 0.001~5A(RMS)
5. Power output:300VA
6. Maximum knee voltage measurement:45kv
7. Current measurement:
Range:0~10A (automatically change range in 0.1/0.4/2/10A)
Error