Product Introduction:
The handheld SF6 gas leak detector is a stable and sensitive leak detector. We have fully considered the actual needs of the majority of users, and at the same time apply our rich technology and experience to this product, allowing users to enjoy an excellent price-performance ratio.
The high-tech central microprocessor unit is the core of the qualitative leak detector for sulfur hexafluoride gas. Its digital signal processing capabilities can better manage circuits and process detection signals. Due to the use of a large number of integrated circuits, the number of components in the circuit is reduced by 40%, which greatly improves reliability and efficiency. The microprocessor can monitor the probe and battery voltage at a rate of 4000 times per second. Even the smallest signal can be captured. It can work stably and reliably in any environment.
The SF6 gas qualitative leak detector has added some convenient functions. Seven-level sensitivity, the sensitivity is increased by 64 times. The three-color LED gradually indicates the degree of leakage in a large range, and is also used to display the sensitivity level and battery power. Touch the keyboard to perform all operations. The avant-garde slender shape design greatly facilitates the user's use and maintenance. It is very convenient to use the indicator light in the direct range.
Technical parameters:
Power supply 3V DC 2 alkaline batteries
Maximum sensitivity R12 R22 R134a approved (14g/year)
Limiting sensitivity about 20 hours
Probe life About 20 hours
Operating temperature 0â??-52â??
Battery life about 30 hours under normal use
Working way continuous unlimited
Response time instantaneous
Reset time 1 SEC
Warm-up time about 2 seconds
Weight 560g
Size 229 65 65mm3
Probe length 35.5cm
Product Introduction: The handheld SF6 gas leak detector is a stable and sensitive leak detector. We have fully considered the actual needs of the majority of users, and at the same time apply our rich technology and experience to this product, allowing users to enjoy an excellent price-performance ratio. The high-tech central microprocessor unit is the core of the qualitative leak detector for sulfur hexafluoride gas. Its digital signal processing capabilities can better manage circuits and process detection signals. Due to the use of a large number of integrated circuits, the number of components in the circuit is reduced by 40%, which greatly improves reliability and efficiency. The microprocessor can monitor the probe and battery voltage at a rate of 4000 times per second. Even the smallest signal can be captured. It can work stably and reliably in any environment. The SF6 gas qualitative leak detector has added some convenient functions. Seven-level sensitivity, the sensitivity is increased by 64 times. The three-color LED gradually indicates the degree of leakage in a large range, and is also used to display the sensitivity level and battery power. Touch the keyboard to perform all operations. The avant-garde slender shape design greatly facilitates the user's use and maintenance. It is very convenient to use the indicator light in the direct range. Technical parameters: Power supply 3V DC 2 alkaline batteries Maximum sensitivity R12 R22 R134a approved (14g/year) Limiting sensitivity about 20 hours Probe life About 20 hours Operating temperature Battery life about 30 hours under normal use Working way continuous unlimited Response time instantaneous Reset time 1 SEC Warm-up time about 2 seconds Weight 560g
Supplier: Gas lighter, led screen protector ( not even in domestic ), refill paper cups, table runner, earing brass clamp, auto brass electric parts, cashew nuts, wire mesh, petha sweet, niwar, mohini powder, vermicompost, dry bath incubator, test tube plastic, sordium citrate tube, health care product, ornamental freshwater fish, safed musli, used polymer bag, cotton linter, auto hood cover, areca plate, rice
Honeywell BW Solo is a easy to service single-gas detector with BLE connectivity that provides real-time visibility into the status and safety of hazardous-area workers, helping companies respond faster, more knowingly and decisively to safety incidents. The first single-gas detector with the 1 Series sensor for CO, H2S and O2 Features & Benefits: User-friendly operation, Easy-to-read display for multiple languages, Lightweight convenience, Ease of maintenance, Serviceability, The new 1-Series sensor for enhanced reliability, Connected Bluetooth Low Energy (BLE) capabilities.
Description: Ultra High Sensitivity SF6 Trace Gas Leak Detector-Q200 Sensor: Electron capture Leak Rate:1 x 10-8 ml/s 0.1ppm [With optional capillary inlet,1 x 10-10mL/s SF6] Response:1 sec (85% of reading) Concentration Sensitivity 0.01 ppm Recovery time 1sec Options Calibrated leaks Battery use time 20 Hours Display Alpha numeric VFD Manufacturing Standards To ISO 9001:2015 Certified,to CE requirements Service life:more than 20years
Portable SF6 Leak detector - Principle: non-dispersive infrared technology (NDIR) - Range: 0-1000ppm or 0-50 ppm - Sensitivity = 1ppm or 0.1 ppm - Accuracy: full range ±5% - Response time: approx.12 second - Power: lithium battery - Operating temperature: 0-50 C
Hard and tough quality Unbreakable
Supplier: Global natural gas, electricity, crude oil, refined products, natural gas liquids (lng/lpg), metals and agricultural commodities
Services: Trade services, freight & shipping
Parameter DR-600 Fixed gas detector Detection Gas Methane (CH4) Range 0-100%LEL Min Reading 1%LEL Display Error �±5%(F.S) Transmission Distance 1,200m Alarm Point Low Alarm:20%LEL High Alarm:50%LEL Rated Power 2.5W Output Signal 4-20ma/RS485 Detection Way Diffused Response Time â?¤60s Cable Specification Three wire system RVVP3*1.0mm2 Working Temp -10â??~55â?? Working Humidity 10~93%RH Storage Temp 10â??~35â?? Sensor Type Catalytic Combustion Power Supply DC24V Production Grade Exd IIC T6 Gb Protection Grade IP66 Electrical interface M20*1.5mm2 Alarm Way Sound alarm Sensor Life Clean air for 2 years Way to Install Fixed bracket/tube mounting/wall mounting Weight 1.75kg Size 210*190*95mm
Product Description: SR-902 Main Features: Auto reset after alarm MCU process Sensor with high stability and low power consumption Detecting natural gas and LPG SMT adopted Technical specification: Operating voltage: AC 220V or DC 9-16V Standby current: less than 90mA or less than 30mA (low power consumption) Alarm current: less than 100mA or less than 40mA (low power consumption) Rated power: less than 3W (AC 220V) Operating temp.: -10 to +50 degrees Working humidity: less than 95%RH Alarm mode: network output / sound & flash alarm / RF Alarm volume: more than 85dB/m Alarm density: 10%LEL Alarm output: relay output (N.C.and N.O. optional) / RF signal Dimension: 70L*40W*110Hmm