5D Metal Oxide Varistor,Website:http://www.chinakestar.com,General Series Metal Oxide Varistor
-
Product Features  Transient surge voltage, small size, large surge current resistance Wide voltage range from several volts to thousands of volts for a single varistor Low limit voltage (residual voltage) Fast response speed (ns level) Symmetrical volt-ampere characteristics No continuous flow Various varieties and specifications (5D, 7D, 10D, 14D, 20D) Passed CQC, VDE, UL certification standards
A metal oxide arrester (MOA) is an electrical device that is designed to protect electrical systems and equipment from surges caused by lightning, switching operations, and other sources of overvoltage. The MOA technology utilizes a metal oxide varistor (MOV) element that provides low impedance paths for high voltage surges, thereby diverting the excess energy to the ground. YF POWER is a leading metal oxide surge arrester suppliers and metal oxide surge arrester manufacturers, recognized for their reliability, durability, and performance. YF POWER's MOA products provide superior protection against lightning and overvoltage surges, making them the ideal choice for use in power distribution systems, substations, wind turbines, and many other applications. YF POWER's MOA products are designed to meet international standards and undergo rigorous testing to ensure high performance and long service life. YF POWER's MOA technology features a robust construction that withstands harsh environmental conditions and provides years of reliable protection. YF POWER offers a range of MOA products, including station-class MOA, intermediate-class MOA, distribution-class MOA, and many more, to meet the diverse needs of customers. YF POWER's commitment to excellence has made it a trusted partner to customers across the globe. Advantages of Metal Oxide Arresters Metal oxide varistor surge arrester offer several advantages over other surge protection devices, including: High Energy Handling Capability: gapless metal oxide surge arrester can handle high energy surges, making them suitable for a wide range of applications, including high voltage and extra high voltage power systems. Fast Response Time: metal oxide type lightning arrester have a faster response time than other technologies, providing immediate protection against overvoltage surges. Low Voltage Protection: Metal oxide arresters can provide low voltage protection, making them suitable for electronic equipment, such as computers and televisions. Long Service Life: Metal oxide arresters have a long service life, which reduces the need for maintenance and replacement. Environmental Resistance: Metal oxide arresters are resistant to harsh environmental conditions, making them suitable for use in various industries, including wind power and oil and gas. Overall, the advantages of metal oxide arresters make them a reliable and effective option for surge protection in a variety of applications. For more information about what material is used in metal oxide arrester and overhead power line hardware, please feel free to contact us!
Metal oxide varistor is the core of the arrester, which main component is zinc oxide and with a small quantity of bismuth oxide, fluoride oxide, manganous carbonate, antimony oxide and other gleam of additive and made with high temperature. Compared with traditional carborundun, mov(metal oxide varistor)has greatly mended voltage current characteristic and improved through-current capability, thereby to line up protection. Standard.
Zinc Oxide Varistor, General Series Metal Oxide Varistor -
Features & application : Large Power capacities,low TCR, low noise Bitmap Better stability in performance and high frequency Small volume,wide range resistance and high resistance tolerance Shot time overload : No visible damage Terminal length : No visible damage Damp heat with load : 5% Endurance characteristic : 5%. 2000pcs/box.
I. Use AC gapless metal oxide arrester (hereinafter referred to as arrester) is used to protect AC electrical equipment of corresponding voltage level from lightning overvoltage and operating overvoltage damage. Product Implementation Standard: GB11032 - 2010 "AC electrical equipment arrester". II. Conditions of Use 1.It is suitable for indoor and outdoor use. 2.Ambient temperature (-40 +40) C;O 3.The maximum solar radiation intensity is 1.1kW/m.2 4.The altitude does not exceed 2000 m. 5.The rated frequency of AC system is (48-62) Hz. 6.The power frequency voltage applied between the arrester terminals for a long time should not exceed the continuous operating voltage of the arrester. 7Earthquake intensity 8 degrees and below; 8.The maximum wind speed does not exceed 35m/s. III. Structure and Characteristics This kind of arrester is assembled by superposition of non-linear zinc oxide resistors and sealed in high voltage insulating ceramic sleeve without any discharge gap.Under normal operating voltage, the arrester is insulated with high resistance; when it is impacted by overvoltage, the arrester is in low resistance state, releasing impulse current into the ground quickly, so that the voltage on the electrical equipment parallel to it is limited to the prescribed value, so as to ensure the safe operation of the electrical equipment.The arrester is equipped with a detachment device. When the arrester operates under overload or suffers accidental damage, the internal pressure increases sharply, so that the arrester can be detached from the device to ensure that the ceramic sleeve is not damaged.The arrester has the characteristics of good steep wave response, high shock current tolerance, low residual voltage, reliable operation, no power frequency continuous current, simple maintenance and so on.
Supplier: Zinc oxide surge arrester, metal oxide varistor, circuit breaker, switch gears
Key specifications/special features for surge arrester: System nominal voltage(kv): 33 Type code of moa: yh10w-30/90 System highest voltage(kv): 36 Rated voltage of arresters(ur)(kv): 30 Continuous operationg voltage(ur)(kv): 24 Nominal discharge current(in)(kv): 10 High current 4/10 impulse withstand(ka): 100 2ms rectangular current(a): 250 Steep current impulse residual voltage(kv): 99 Lightning impulse residual voltage(kv) 5ka: 85 10ka: 90 20ka: 101 Switching current impulse residual voltage(kv): 69 Lind discharge class: i Pressure relief class: b, 20 Insulation impulse withstand voltage(kv): 170 Power frequency withstand voltage(kv): 95 Max. External riv(v):
Supplier: NTC thermistor leaded sensor and components, PPTC, resettable fuse, zinc oxide varistor, thermal cutoff, thermostats, pt sensor, thermistors