Leica GEB70 TPS Serise Total Station And GPS External Battery,Website:http://www.china-seco.com,Total Station Battery
Leica GEB121 TPS Series Total Station Battery,Website:http://www.china-seco.com,Total Station Battery
Control Cable are PVC insulation, XLPE insulation, fluoroplastic Insulation materials, different materials such as silicone rubber insulation performance cable products for In power stations, substations, factories, petrochemical, and other companies controlled remotely controlled loop, as the connection between the lines of various types of electrical instrumentation and automation devices, from the role of the various power or signal transmission, so that the entire electrical system safe, Reliable operation. Control cable is suitable for power station, substation, factory and petrochemical industry.
The electric vehicle charging cable is used to connect the electric vehicle charging device and charging infrastructure, so as to carry out power transmission for electric vehicles, and is equipped with a certain number of signal lines, control lines, power auxiliary lines, etc., to ensure accurate control and safe operation of the whole charging process. Charging cable is generally used in charging station, parking lot, hotel, residential area, garage and other areas, portable charging cable can be placed in the car. Hualin electric vehicle charging cables are designed and produced according to TuV Rheinland technical standards. Hualin Cable's electric vehicle charging cable products have the following advantages: soft, feel good, bending radius is less than 5D; Oil resistance, acid and alkali resistance, water resistance, wear resistance, rolling resistance, cracking resistance, UV resistance, color stability; Good flame retardant performance; Bending resistance more than 50000 times; All materials comply with RoHS&REACH latest environmental standards. Charging cables are generally used in charging stations, parking lots, hotels, residential areas, garages and other areas.
Flexible fireproof cables are composed of copper stranded wires, mineral compound insulation, and mineral compound sheaths. This kind of cable has non-combustible, smoke-free, non-toxic and fire-resistant characteristics. The structure of the flexible mineral insulated cable adopts a flexible structure and materials that are made of mineral compounds, which make up for the defects of hard structure, flammability, and toxicity. It also has some advantages that other cables cannot have, such as: fire resistance, large current carrying capacity, Impact voltage resistance, mechanical damage resistance, halogen-free, non-toxic, explosion-proof, waterproof, corrosion resistance, long life, safety, overload resistance, high temperature resistance, low cost, etc. Flexible fireproof cables have an important role in protecting lives, materials, and information security. They are used in trunk lines, fire lines, escape rescue systems, such as emergency lighting, fire monitoring, alarm systems, elevator systems, smoke exhaust systems, and control lines, etc. Flexible fireproof fireproof cables used in trunk lines, fire lines, escape and rescue systems, such as emergency lighting, fire monitoring, alarm system, elevator system, smoke exhaust system, and control lines, etc. Flexible fireproof fireproof cables used in Public buildings: high-rise buildings, underground buildings, hotels and restaurants, hospitals, schools, business centers, government affairs centers, department stores, large supermarkets, logistics warehouses, financial institutions such as banks, securities and insurance, post and telecommunications centers, power control rooms, substation rooms, museums, memorials and other historic buildings. Flexible fireproof fireproof cables used in Infrastructure: airport terminals, stations, hub centers, ports, subway systems, Bridges, tunnels. Flexible fireproof fireproof cables used in Industry: coal mining, coal chemical industry, oil field mining, petrochemical industry, oil refinery, metallurgical industry, iron and steel industry, shipbuilding industry, aerospace, electric power industry, pharmaceutical industry, glass industry, paper industry, military system. Flexible fireproof fireproof cables used in Fire prevention, explosion prevention, high temperature places: oil depot and gas station, natural gas transmission and compression station, garden landscape, historic sites, wood structure buildings
Supplier: Cast resin transformer, oil filled distribution transformer, load break switch panel, unitised sub station, resin cast potential transformer
Cable Features - Special heat resistant insulation - Higher current carrying capacity. - Fine copper wires - Highly thermal stable insulation - Excellent resistant to moisture, abrasion, grace, oil - Long Life - Excellent mechanical & electrical properties Cable Standard IS : 694 : 2010 & BS 6004, BS EN 50525-2-31 Application Fixed installation in conduits and under plaster, for appliance wiring and distribution stations. Standard Packing Coils 90 and 180m Conductor Flexible Bare Copper conductor class-2 and class-5 as per IS: 8130 EN 60228 Insulation HR/FR/FRLS-H/ZHFR Insulation compound with a high insulation resistance value as per IS:5831 Color Red, Yellow/green, Blue, Black, Brown, Grey, Orange, White, Green, Yellow Properties PVC Self-extinguishing and flame retardant according to EN 60332-1-2
Silent Features (FR and FRLS) - Good Flame Retardant Properties - Excellent resistant to moisture, abrasion, grace, oil - Long Life - Excellent mechanical & electrical properties - Steam and boiling water resistant Silent Features (ZHFR) - Zero Halogen acid gas Evolution - Non-corrosive and non-toxic insulation - High-temperature resistant insulation - Better Flame retardant property - Excellent resistance to moisture, abrasion, grace, oil - Long Life Technical Data Operating Temp : -10Cto max.+90C Nominal voltage : 1.1 KV Test voltage : 3.0 KV Flame propagation : Flame retardant test as per IS 10810-58,64, IEC 60332-1 Standard Packing Coils 90m, 180m and 360m Conductor Annealed flexible bare Copper class-2 and class-5 Conductor as per IS:8130-1984 Insulation PVC FR, FRLS,HRFR,ZHFR as per IS:5831-1984 Color Red, yellow, Blue, Black, Brown, Grey, Orange, White, Green, Yellow/green or as per customer requirement Application Fixed installation in conduits and under plaster, for appliance wiring & distribution stations. Fixed Wiring in Conduits & Building wire Application
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Cable Standard Generally conforms to, Based on IS:9857-1990 VDE 0282, IEC 245-6, BS 6899 Silent Features - Ultra high performance flexible welding lead, double insulated for longer life and added safety - Better flame retardant properties - Outstanding toughness & durability - High resistance to cuts, tears & abrasion - Resistance to oil, solvents and chemicals - Excellent ozone and weather resistant Technical Data Fixed Installation : -20C to max.+90C Nominal Voltage : 600 V Spark Test : 3.5 KV(ac) Color : Orange / Black Jacket Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200, 300 and 500m Conductor High conductivity, bare annealed copper flexible conductor, EC copper class 5 & class 6 generally conforms to IS:8130-1984, IEC 60228 Separation Polyester tape Insulation Double Insulated/single insulated flexible Nitrile rubber HOFR insulated as per IS:6380-1984 Color Orange / Black Jacket Current Rating The maximum current ratings of flexible welding cables for different duly cycles are based on an ambient air temperature of 25 C and a maximum conductor temperature of 90 C. The percentage duly cycles for various processes and applications are as follows: - Automobile Welding : up to 100% - Semi Automatic Welding : 30% to 85% - Manual Welding : 0% to 60% - Very intermittent or Occasional Welding : up to 20% Voltage Drop When total cable lengths in excess of 15mtr., are involved, it may be necessary to use cables of larger cross section to ensure that the voltage drop is not excessive & welding currents are maintained at adequate levels. Application Designed for the secondary (high current) connection to automatic or hand - held metal arc welding electrodes. It is suitable for flexible use under rugged conditions, on assembly lines & conveyor systems, in machine tool and automatically operated line & spot welding machines