DGS-Ethanol 968-035 Digital Breath Alcohol Sensor Module DESCRIPTION
Easily add Breath Alcohol sensing to your IoT application with our digital gas sensor module that provides a calibrated and temperature compensated output.
0 to 800 ppm Breath Alcohol sensor with digital output.
DGS-Ethanol 968-035 Digital Breath Alcohol Sensor Module BENEFITS
* Low Power 1 mW @ 1 minute sampling
* Calibrated & Temp. Compensated Output
* Simple Digital UART Interface
* Integrated T & RH Sensors
* Robust 10-year Estimated Lifetime
* ROHS Compliant
* Small form Factor
* UART to USB adapter provided
* Lightweight (< 2 oz.)
DGS-Ethanol 968-035 Digital Breath Alcohol Sensor Module APPLICATIONS
* Breathalyzer
* Breath Alcohol Detector
DGS-Ethanol 968-035 Digital Breath Alcohol Sensor Module MEASUREMENT PERFORMANCE CHARACTERISTICS
Based on Standard Conditions 25 degree C, 50% RH and 1 atm
* Measurement Range: 0 to 800 ppm
* Resolution: 0.3 ppm
* Measurement Accuracy: 15% of reading
* Measurement Repeatability: < ± 3% of reading
* T90 Response Time (100 ppm step): < 60 seconds
* Power Consumption:
1 mW for 1 minute triggered samples
12 mW for continuous sampling 5, 10 30, 60 second intervals
* Expected Operating Life: > 5 years (10 years @ 25± 10C; 60 ± 30% RH)
* Operating Temperature Range: -20 to 40 degree C (-30 to 55 degree C intermittent)
* Operating Humidity Range: 15 to 95% (0 to 100% non-condensing intermittent)
* Mechanical Dimensions: 1.75 x 0.82 x 0.35 in. (44.5 x 20.8 x 8.9 mm)
* Weight: < 2 Ounces
Supplier: Wireless charger, batteries power bank, dust sensor, optical disc drive, tof, lidar, ar glass
We Can Supply Freestyle Libre 2 Flash Glucose Monitoring System Sensor Please Dont Hesitate to Contact Us in Case of Any Interested
Supplier: Solvent distillation plant , ethanol distillation plant , etp, water treatment plant , effluent treatment plant, evaporator , dryer, zld plant, lab equipment supplier, lab chemical supplier, industrial equipment , storage tank , bulk tank, petrochemical plant, ethyl acetate distillation plant, supplier of chemicals, reactor , pressure vessel , instruments, plc panel ,dcs panel, mcc panel , steam boiler, agitator tank, mixing tank, blending tank, bottling plant , vodka plant , ena distillation plant , fermentation plant , cooking plant, cpu plant, dg set, dpr report. etc, industrial dryer, industrial storage tanks, lab equipment, bio cng plant, biogas plant, bioreactor, sludge settling tank, wash settling tanks, pre fermenters, culture vessel, blender, blending tank, agitator, mixing tank, shell and tube heat exchanger, reboiler, reactor, mcc electrical panel, pressure vessel, evaporator, industrial dryer, beer plant, brewery plant, ethanol distillery , grain alcohol distiller plant
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
AC to DC converter battery charger 150-1000VDC rectifier 120KW power supply Product Introductionï¼? SANDI AC/DC Charger is specially developed for DC chargers. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase, DC output voltage range from 150 to 1000VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger. Unique function High efficiency over the full load range, full load efficiency greater than 95% Wide output voltage range, 150-1000VDC, suitable for a wide range of Lithium or lead acid battery 5-inch LCD touch screen, easy to operate Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate Main featuresï¼? Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc. Wide input voltage range: 260~ 530Vac, adaptable to various power grid environments Three-phase AC input without neutral wire: Simplifies system design, eliminates the risk of excessive neutral current, and reduces system costs. Dual DSP design, achieve the full digital control, less components means high reliability Wide input voltage range, allows operation in most poor grid conditions Battery anti backflow: effectively protects the battery while ensuring reliable and safe operation of the system Input, output have protective circuit breaker switch Module adopts hot pluggable design, which is convenient for maintenance. RS485 interface (Optional)
Photocells Fans & ventilation, Hazardous area lighting Industrial plugs & sockets Industrial & commercial Lamps Light fittings: fluorescent, weatherproof & floodlighting Refrigeration & air conditioning spares Water heating elements Wiring accessories MCB's Circuit breaker Vacuum Breakers Control transformers Fuses & load break devices Hazardous area products Industrial beacons Industrial sounders, buzzers Industrial surge protection Safety switches Clamp meters Multi-meters Testers Semiconductors: thyristors, rectifiers Pressure switches Solenoid & pilot valves Photoelectric Sensors
Product Overview The ignition point of a fire inside the electric panel is mostly the part where the terminal block is fastened, so in order for initial fire extinguishing, the solution should be closely installed to the part where the terminal block is fastened. In the case of a small electric panel, a complete initial fire extinguishing is expected for fires occurring inside the electric panel by attaching the SFEX Pad to the top surface of the electric panel. Product Feature It has an excellent performance in the initial fire suppression as it can be installed near the ignition point as a flexible rope type. It uses a stand-alone method based on polymer chemistry so that it does not cause malfunctions and maintenance costs. The thermo-responsive Granule composed of KNO3 and subsidiary catalysts It does not affect the peripherals after the fire goes out. Function of SFEX Granule = fire extinguishing agent storage tank + temperature sensor + nozzle function Fire extinguishing method : Suffocation + subsidiary catalyst Example of Installation 1 : SFEX Line - If ducts exist Installing the SFEX Line horizontally or vertically in the ducts closest to the expected ignition points It can be installed without damaging the panel Example of Installation 2 : SFEX Line - If ducts do not exist Installing the SFEX Line horizontally or vertically, close to the expected ignition points of the Electric panel Example of Installation 2 : SFEX Pad - Small Electric Panel Simply attach it to the top inside the Electric panel.