Place of Origin:
Beijing, China (Mainland)
Brand Name:
HYLITON POWER
Model Number:
LXZ250250180060
Usage:
Current
Phase:
Single
Coil Structure:
Toroidal
Coil Number:
Autotransformer
Rated frequency:
50Hz or 60Hz
Rated secondary current:
5A or 1A
Rated short-time thermal current:
40kA,1s
Rated continuous thermal current:
120%In
Continuous power-frequency voltage:
3kV , 1min
Instrument security factor:
FSâ?¤10
Application condition
Ambient temperature
-25-+40
Average temperature of day
â?¤40
Altitude
â?¤3000m
Pollution class
III
Technical data
Rated frequency
50Hz or 60Hz
Rated secondary current
5A or 1A
Rated short-time thermal current
40kA,1s
Rated continuous thermal current
120%In
Continuous power-frequency voltage
3kV , 1min
Instrument security factor
FSâ?¤10
Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006 Rated primary current 20-600A Rated load 10VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS10 Mechanical parameters Dimensions (WDH) (mm) 18 130 55 Weight (kg) 2.3 Operating conditions Operating temperature -35C to +55C Daily average temp
Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006 Rated primary current 500-1500A Rated load 20VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS10 Mechanical parameters Dimensions (WDH) (mm) 120x185x100 Weight (kg) 7 Operating conditions Operating temperature -35C to +55C Daily average temp
TRANSFORMER : ALL TYPE : Dry Type/Air Cooled, Oil Cooled, Water. We can supply small transformer from 33kV and up to 54000kVA or more. For more details please contact us.
Supplier: Pure sine wave off grid inverter, energy storage lithium battery, solar charge controller, ac/dc battery charger and single phase to 3 phase converter, pv combiner box and power supply
D363 & D364 range of current transformers are combination designed 3 CT in 1, save more space comparing general unit CT, suitable for primarycurrent 75A to 600A, supporting the use of molded case circuit breaker according to the rated current size.
We can supply solar transformers ideally suited for large MW scale solar PV plants. Bullet Points - . Inverter duty Solar transformers, suitable for solar load profile . Multi-winding (2 to 6 windings), oil-filled or dry type. . 2MVA to 12.5MVA, LV Side: 0.35kV to 0.69kV, HV Side 3.3kV to 33kV . Low-loss, with Aluminum or Copper winding. . Electrostatic shield between LV and MV Winding. For more details please contact us.
For price, specification and other details please contact us